Patton CopperLINK  2174 Скачать руководство пользователя страница 5

5

tion. The device has been tested and found to comply with the limits for a 
Class A computing device in accordance with specifications in Subpart B 
of Part 15 of FCC rules, which are designed to provide reasonable pro-
tection from such interference in a commercial installation. However, 
there is no guarantee that interference will not occur in a particular instal-
lation. If the device does cause interference to radio or television recep-
tion, which can be determined by disconnecting the unit, the user is 
encouraged to try to correct the interference by one or more of the follow-
ing measures: moving the computing equipment away from the receiver, 
re-orienting the receiving antenna and/or plugging the receiving equip-
ment into a different AC outlet (such that the computing equipment and 
receiver are on different branches).

1.3  CE DECLARATION OF CONFORMITY

Patton Electronics, Inc declares that this device is in compliance with the 
essential requirements and other relevant provisions of Directive 
2004/108/EC relating to electromagnetic compatibility and Directive 
2006/95/EC relating to electrical equipment designed for use within cer-
tain voltage limits.  The Declaration of Conformity may be obtained from 
Patton Electronics, Inc at www.patton.com/certifications.

The safety advice in the documentation accompanying this device shall 
be obeyed. The conformity to the above directive is indicated by CE 
mark on the device.

1.4  AUTHORIZED EUROPEAN REPRESENTATIVE

D R M Green

 

European Compliance Services Limited.

 

Avalon House, Marcham Road

 

Abingdon, Oxon  OX14 1UD, UK

1.5  SERVICE

All warranty and non-warranty repairs must be returned freight prepaid 
and insured to Patton Electronics. All returns must have a Return Materi-
als Authorization number on the outside of the shipping container. This 
number may be obtained from Patton Electronics Technical Services at: 

• Tel: 

+1

 

(301) 975-1007

• Email: 

[email protected]

• URL: 

http://www.patton.com

Note

Packages received without an RMA number will not be 

accepted.

Содержание CopperLINK 2174

Страница 1: ...t Extender SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 Part 07M2174 UM Rev D Revised 7 5 12 An ISO 9001Certified Company This is a Class A device and is not intended for use in a resident...

Страница 2: ...100Base T Ethernet Interface 12 3 3 Connecting the POTS ISDN Line 2174 S 13 3 4 Connecting Power 13 4 0 Configuration 14 4 1 Configuring the Hardware DIP switches 14 4 2 Configuring DIP Switch S1 14 S...

Страница 3: ...3 C 1 10 100Base T Interface 19 RJ 45 19 C 2 CopperLINK Interface 19 RJ 45 19 Terminal Block 19 C 3 POTS ISDN Interface 2174 S 19 RJ 45 19 D Line Rate Reach Chart Based on 24 AWG 0 5 MM 20...

Страница 4: ...l or consequential damages arising from the use of or inability to use this product Patton Electronics spe cifically disclaims all other warranties expressed or implied and the installation or use of...

Страница 5: ...is device is in compliance with the essential requirements and other relevant provisions of Directive 2004 108 EC relating to electromagnetic compatibility and Directive 2006 95 EC relating to electri...

Страница 6: ...e used meets all applicable standards for the country in which it is to be installed For AC powered devices which have 3 conductor power plugs L1 L2 GND or Hot Neutral Safety Protective Ground the wal...

Страница 7: ...ipment Electrostatic Discharge ESD can damage equipment and impair electrical circuitry It occurs when electronic printed circuit cards are improperly handled and can result in complete or intermitten...

Страница 8: ...ation LED indicators for Power DSL Link Ethernet Link Activity Remote and Local 2 2 DESCRIPTION The Patton Electronics Model 2174 CopperLink modems provide high speed LAN connections between peered Et...

Страница 9: ...the units refer to section 3 1 Connecting the Line Interface on page 11 Note See Figure 2 for the Model 2174 s rear panel arrangements 2 Connect the Ethernet interface refer to section 3 2 Connecting...

Страница 10: ...10 S Figure 2 Model 2174 rear panel options Eth3 Eth0 Eth1 Eth2 12VDC 1A Eth3 Eth0 Eth1 Eth2 12VDC 1A Eth3 Eth0 Eth1 Eth2 12VDC 1A Eth3 Eth0 Eth1 Eth2 12VDC 1A...

Страница 11: ...6 AWG 0 4mm Leased circuits that run through signal equalization equipment are not acceptable 2 The Model 2174 is equipped with an RJ 45 interface jack Figure 3 or terminal block Figure 4 that can be...

Страница 12: ...to a 10 100Base T device or network Figure 5 shows the signal pin relationships on this interface You may connect this port to a hub or PC using a straight through or crossover cable that is up to 328...

Страница 13: ...he barrel jack on the rear panel of the Model 2174 No configuration is necessary for the power supply See Appendix B for domestic and international power supply and cord options DC power supplied via...

Страница 14: ...rientation of the DIP switches in the On and Off positions Figure 7 DIP switch orientation 4 2 CONFIGURING DIP SWITCH S1 DIP switch S1 is where you configure the CopperLINK line The following tables d...

Страница 15: ...itch S1 5 General Protection Signal to Noise Ratio Use switch S1 5 to configure line noise protection 6dB Original line noise protection with 6dB SNR 9dB Better line noise protection with SNR up to 9d...

Страница 16: ...ws the front panel location of each LED Table 5 on page 16 describes the LED functions Figure 8 Model 2174 front panel Table 5 Front panel LED description LED Status Description Power Green The device...

Страница 17: ...nce Up to 9 842 ft 3 km Note Distances depend on line rate and line conditions A 4 LED STATUS INDICATORS Power Green CopperLINK Link Green Local Green Remote Green Ethernet Link Green Activity Flashin...

Страница 18: ...mote Terminal Block Line 100 240VAC 2174 BNC EUI 2PK High Speed CopperLink Ethernet Extender Kit Local and Remote BNC Line 100 240VAC 2174 S EUI 2PK High Speed CopperLink Ethernet Extender Kit Local a...

Страница 19: ...45 Pin 1 TX Pin 2 TX Pin 3 RX Pin 6 RX Pins 4 5 7 8 no connection C 2 COPPERLINK INTERFACE RJ 45 Pin 4 RING Pin 5 TIP Pins 1 2 3 6 7 8 no connection Terminal Block C 3 POTS ISDN INTERFACE 2174 S RJ 45...

Страница 20: ...inter face Model 2174 EUI and 2174 TB Contact Patton for Model 2174 BNC rates Table 6 Line Rate Reach Chart Using Twisted Pair Long Range Mode Long Range Distance in Feet Mbps ft m km DS US Symmetric...

Страница 21: ...nter face Model 2174 EUI and 2174 TB Contact Patton for Model 2174 BNC rates Table 7 Line Rate Reach Chart Using Twisted Pair High Speed Mode High Speed Distance in Feet Mbps ft m km DS US Symmetric 2...

Страница 22: ...______________________________________________ _________________________________________________________ _________________________________________________________ _____________________________________...

Страница 23: ...______________________________________________ _________________________________________________________ _________________________________________________________ _____________________________________...

Страница 24: ...24 Copyright 2011 2012 Patton Electronics Company All Rights Reserved...

Отзывы: