Patton CopperLINK  2174 Скачать руководство пользователя страница 21

21

Note

The actual distance and link performance may vary depending 

on the environment and type/gauge of wire used.

Note

DS = downstream, US = upstream

Note

This chart applies to Model 2174s with a twisted-pair line inter-

face: Model 2174/EUI and 2174/TB. Contact Patton for Model 
2174/BNC rates. 

Table 7: 

Line Rate & Reach Chart Using Twisted-Pair (High Speed)

Mode

(High Speed)

Distance in Feet 

Mbps

ft

m/km

DS

US

Symmetric

250 ft

76 m

121

144

1000 ft

305 m

73

103

2,000 ft

610 m

45

37

3,000 ft

914 m

46

10

3,500 ft

1 km

30

4

Asymmetric

250 ft

76 m

168

95

1000 ft

305 m

126

54

2,000 ft

610 m

60

21

3,000 ft

914 m

42

6

3,500 ft

1 km

35

1

Содержание CopperLINK 2174

Страница 1: ...t Extender SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 Part 07M2174 UM Rev D Revised 7 5 12 An ISO 9001Certified Company This is a Class A device and is not intended for use in a resident...

Страница 2: ...100Base T Ethernet Interface 12 3 3 Connecting the POTS ISDN Line 2174 S 13 3 4 Connecting Power 13 4 0 Configuration 14 4 1 Configuring the Hardware DIP switches 14 4 2 Configuring DIP Switch S1 14 S...

Страница 3: ...3 C 1 10 100Base T Interface 19 RJ 45 19 C 2 CopperLINK Interface 19 RJ 45 19 Terminal Block 19 C 3 POTS ISDN Interface 2174 S 19 RJ 45 19 D Line Rate Reach Chart Based on 24 AWG 0 5 MM 20...

Страница 4: ...l or consequential damages arising from the use of or inability to use this product Patton Electronics spe cifically disclaims all other warranties expressed or implied and the installation or use of...

Страница 5: ...is device is in compliance with the essential requirements and other relevant provisions of Directive 2004 108 EC relating to electromagnetic compatibility and Directive 2006 95 EC relating to electri...

Страница 6: ...e used meets all applicable standards for the country in which it is to be installed For AC powered devices which have 3 conductor power plugs L1 L2 GND or Hot Neutral Safety Protective Ground the wal...

Страница 7: ...ipment Electrostatic Discharge ESD can damage equipment and impair electrical circuitry It occurs when electronic printed circuit cards are improperly handled and can result in complete or intermitten...

Страница 8: ...ation LED indicators for Power DSL Link Ethernet Link Activity Remote and Local 2 2 DESCRIPTION The Patton Electronics Model 2174 CopperLink modems provide high speed LAN connections between peered Et...

Страница 9: ...the units refer to section 3 1 Connecting the Line Interface on page 11 Note See Figure 2 for the Model 2174 s rear panel arrangements 2 Connect the Ethernet interface refer to section 3 2 Connecting...

Страница 10: ...10 S Figure 2 Model 2174 rear panel options Eth3 Eth0 Eth1 Eth2 12VDC 1A Eth3 Eth0 Eth1 Eth2 12VDC 1A Eth3 Eth0 Eth1 Eth2 12VDC 1A Eth3 Eth0 Eth1 Eth2 12VDC 1A...

Страница 11: ...6 AWG 0 4mm Leased circuits that run through signal equalization equipment are not acceptable 2 The Model 2174 is equipped with an RJ 45 interface jack Figure 3 or terminal block Figure 4 that can be...

Страница 12: ...to a 10 100Base T device or network Figure 5 shows the signal pin relationships on this interface You may connect this port to a hub or PC using a straight through or crossover cable that is up to 328...

Страница 13: ...he barrel jack on the rear panel of the Model 2174 No configuration is necessary for the power supply See Appendix B for domestic and international power supply and cord options DC power supplied via...

Страница 14: ...rientation of the DIP switches in the On and Off positions Figure 7 DIP switch orientation 4 2 CONFIGURING DIP SWITCH S1 DIP switch S1 is where you configure the CopperLINK line The following tables d...

Страница 15: ...itch S1 5 General Protection Signal to Noise Ratio Use switch S1 5 to configure line noise protection 6dB Original line noise protection with 6dB SNR 9dB Better line noise protection with SNR up to 9d...

Страница 16: ...ws the front panel location of each LED Table 5 on page 16 describes the LED functions Figure 8 Model 2174 front panel Table 5 Front panel LED description LED Status Description Power Green The device...

Страница 17: ...nce Up to 9 842 ft 3 km Note Distances depend on line rate and line conditions A 4 LED STATUS INDICATORS Power Green CopperLINK Link Green Local Green Remote Green Ethernet Link Green Activity Flashin...

Страница 18: ...mote Terminal Block Line 100 240VAC 2174 BNC EUI 2PK High Speed CopperLink Ethernet Extender Kit Local and Remote BNC Line 100 240VAC 2174 S EUI 2PK High Speed CopperLink Ethernet Extender Kit Local a...

Страница 19: ...45 Pin 1 TX Pin 2 TX Pin 3 RX Pin 6 RX Pins 4 5 7 8 no connection C 2 COPPERLINK INTERFACE RJ 45 Pin 4 RING Pin 5 TIP Pins 1 2 3 6 7 8 no connection Terminal Block C 3 POTS ISDN INTERFACE 2174 S RJ 45...

Страница 20: ...inter face Model 2174 EUI and 2174 TB Contact Patton for Model 2174 BNC rates Table 6 Line Rate Reach Chart Using Twisted Pair Long Range Mode Long Range Distance in Feet Mbps ft m km DS US Symmetric...

Страница 21: ...nter face Model 2174 EUI and 2174 TB Contact Patton for Model 2174 BNC rates Table 7 Line Rate Reach Chart Using Twisted Pair High Speed Mode High Speed Distance in Feet Mbps ft m km DS US Symmetric 2...

Страница 22: ...______________________________________________ _________________________________________________________ _________________________________________________________ _____________________________________...

Страница 23: ...______________________________________________ _________________________________________________________ _________________________________________________________ _____________________________________...

Страница 24: ...24 Copyright 2011 2012 Patton Electronics Company All Rights Reserved...

Отзывы: