2 • Configuration
Figure 3. Underside of CL1300R showing location of DIP switches
The three sets of DIP switches on the underside of the CL1300R are referred to as
S1
,
S3
and
S4
. For basic
configuration
, use DIP switch
S1
. For
testing
the CL1300R, use DIP switch
S3
.
To configure the
rate
, use DIP switch
S4
. This figure shows the DIP switch orientation with
respect to
ON
and
OFF
positions is consistent for all switches.
DIP switch settings
You can configure the CL1300R by setting the DIP switches to the desired positions
before
you
power up the CopperLink. If the DIP switches are set to anything other than all
OFF
or all
ON
,
the CopperLink will operate in DIP switch configuration mode. Once the device is powered up
and operating in DIP switch configuration mode, you cannot change configuration by any
method until you power it down again.