![Patton electronics SMARTNODE 1200 Скачать руководство пользователя страница 128](http://html2.mh-extra.com/html/patton-electronics/smartnode-1200/smartnode-1200_getting-started-manual_4022489128.webp)
1. Configure IP address
128
SmartNode 1000 and 2000 Series Getting Started Guide
10 • Quick start
1. Configure IP address
Power connection and default configuration
First the SmartNode must be connected to the mains power supply with the power cable. Wait until the Run
LED stops blinking and lights constantly. Now the SmartNode is ready.
The factory default configuration for the Ethernet interface IP addresses and network masks are listed in
table 39
.
Both Ethernet interfaces are activated upon power-up.
If these addresses match with those of your network, go to section
“2. Connect the SmartNode to the network”
on page 130. Otherwise, refer to the following sections to change the addresses and network masks.
Connect with the serial interface
The Console port is wired as an EIA-561, RS-232 port. Use the included Model 16F-561 adapter and cable (see
figure 86
) between the SmartNode’s Console port and a PC or workstation’s RS-232 serial interface. Activate the
terminal emulation program on the PC or workstation that supports the serial interface (e.g. HyperTerm).
Figure 86. Connecting to the terminal
Table 39. Factory default IP address and network mask configuration
IP Address
Network Mask
Interface Ethernet 0 (ETH0)
172.16.40.1
255.255.0.0
Interface Ethernet 1 (ETH1)
192.168.1.1
255.255.255.0
Serial Terminal
RJ-45, male
TxD
TxD
GND
GND
6
3
4
5
Sub-D, 9 pol, female
2
3
5