3. Connecting the IpLink to the network
31
IpLink 2884 Getting Started Guide
4 • Initial configuration
Login
To access the IpLink, start the Telnet application. Type the default IP address for the router into the address
field:
192.168.200.10
. Accessing your IpLink via a Telnet session displays the login screen. Type the factory
default login:
admin
and password:
<blank>
.
login:
admin
password:
Trinity#
Changing the IP address
You can set your IP address and network mask for the interface
ETH 0 (LAN)
. Within this example a network
192.168.1.1/24 address is assumed. The IP address in this example is set to
192.168.1.1
(you should set this
the IP address given to you by your network provider).
Trinity# configure
Trinity[config]# interface ethernet eth0
Trinity[eth-eth0]# no ip address 192.168.200.10
Trinity[eth-eth0]# ip address 192.168.1.1 netmask 255.255.255.0
Copy this modified configuration to your new start-up configuration. This will store your changes in non-vol-
atile memory. Upon the next start-up the system will initialize itself using the modified configuration.
Trinity#
copy running-config startup-config
Trinity#
The IpLink can now be connected to your network.
3. Connecting the IpLink to the network
In general, the IpLink will connect to the network via the
LAN (ETH 0)
port. This enables the IpLink to offer
routing services to the PC hosts on
LAN (ETH 1)
port. The IpLink 2884 Series is equipped with Auto-MDX
Ethernet ports, so you can use straight-through or crossover cables for host or hub/switch connections.
You can check the connection with the ping command from the IpLink to another host on the network.
Trinity#ping <IP Address of the host>
Note
If the WAN address is
not
set to DHCP, to ping a device outside your local
LAN you must first configure the default gateway.
Note
For more detailed configuration instructions, see the
IPLink
2884 Adminis-
trator’s Reference Guide
located on the CD that shipped with your unit or
online at www.patton.com.
The interconnecting cables shall be acceptable for external use
and shall be rated for the proper application with respect to volt-
age, current, anticipated temperature, flammability, and
mechanical serviceability.
CAUTION
Содержание IpLink 2884
Страница 19: ...19 Chapter 2 Applications overview Chapter contents Typical IPLink 2884 Application 20...
Страница 41: ...41 Appendix C Cabling Chapter contents Introduction 42 Console 42 Ethernet 43 E1 Port 44 T1 Port 45...
Страница 46: ...46 Appendix D Port pin outs Chapter contents Introduction 47 Console port 47 Ethernet 48 T1 E1 port 48...