The Model IM1/14 module plugs into Patton’s fiber and copper

baseband modems to provide Ethernet LAN extension.  The IM1/14
has no switches or jumpers and does not need to be configured.
However, factors such as type of medium, throughput across the link
and clocking mode must be determined by the settings of the base-
band modems.  Please refer to your baseband modem (i.e. 1092A,
1095, etc) to make the following settings.

1)

Bit Rate:  The DTE rate setting of your base unit corresponds
to the throughput of your IM1/14 bridge module.  Use higher
speeds to allow maximum throughput to your extended LAN.    

NOTE: The IM1/14 only supports synchronous speeds.

2)

Clocking Mode: Set the clocking modes on the base units
so that one unit is configured for Internal clocking mode and
the other unit is set for Receive Recover clocking mode.  

3)

All other base unit settings depend upon your application and
on the application medium (twisted pair or coaxial cable)

44..00 

 

IIN

NSSTTA

ALLLLA

ATTIIO

ON

N

The Model IM1/I4 is completely plug and play. This section tells

you how to make the connections.  

4.1  INSTALLING THE  QUICKCONNECT™ MODULE

Each Quick Connect Module™ has a 50-pin card edge connector

on one side and an ethernet interface on the other.  The instructions
below describe how to remove the existing  QuickConnect™ Module
and how to install the new IM1/I4 module.   If your base unit does not
have an existing QuickConnect™ already installed, please skip to sec-
tion 4.1.2.

4.1.1  Removing the Existing QuickConnect™ Module 

1)  Turn the power switch off.  Leave the power cord plugged into

a grounded outlet to keep the unit grounded.

2)  Loosen the two thumbscrews on the module by turning them

counterclockwise.

3)  Grasp the two thumbscrews and gently pull the module from

the unit.  Apply equal force to the thumbscrews to keep the
module straight during the removal process

7

8

BASE UNIT CLOCK MODES

Unit “A”

Unit “B”

Internal Clock Setting

Receive Recover Clock Setting

NOTE:  Unit “A” and Unit “B” are arbitrarily chosen.  It does not matter which
unit is “A”, and which is “B”.

Содержание IM1/I4

Страница 1: ...ernet Bridge with Integral 4 Port Hub QuikConnect Module SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07MIM1 I4 C Doc 090141UC Revised 07 19 00 C E R T I F I E D A...

Страница 2: ...by the user 1 1 RADIO AND TV INTERFERENCE The Model IM1 I4 generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instruc...

Страница 3: ...address aging 2 2 DESCRIPTION The Patton Model IM1 I4 QuikConnect is an Ethernet Bridge with built in four 4 port hub The IM1 I4 interface module provides LAN extension when used in conjunction with...

Страница 4: ...Cisco router with a serial interface configured as a PPP Half Bridge The router serial interface uses a remote device that supports PPP bridging to function as a node on the remote Ethernet network Th...

Страница 5: ...ation medium twisted pair or coaxial cable 4 4 0 0 I IN NS ST TA AL LL LA AT TI IO ON N The Model IM1 I4 is completely plug and play This section tells you how to make the connections 4 1 INSTALLING T...

Страница 6: ...NG TO THE 10BASE T ETHERNET PORT The RJ 45 Ethernet port on Model IM1 I4 is designed to connect directly to a 10BaseT network Figure 5 below shows the 10BaseT RJ 45 port pin description You may make c...

Страница 7: ...quires a 10Base T connection After power is applied the IM1 I4 automatically starts performing the bridging function without further user intervention MAC addresses discovered are automatically loaded...

Страница 8: ...ved the status code will no longer appear TP1 Green On indicates that port 1 is receiving link integrity or a packet 13 14 COL Yellow On pulse indicates that collisions are detected in the LAN TP2 Gre...

Страница 9: ...94A 1095 1184 and 1185 LED Indicators SYS TP1 COL TP2 WANF TP3 BSAT and TP4 Power Supply 5 Volts 510 mA supplied to module by connection to Patton QuikConnect interface Temperature Range 32 to 122 F 0...

Отзывы: