manualshive.com logo in svg
background image

 

 

 

Diamond Edge Model 3224

 

G.SHDSL IpDSLAM

 

Installation Guide

 

Sales Office:

 

 

+1 (301) 975-1000

 

Technical Support:

 

 

+1 (301) 975-1007

 

E-mail:

 

 

[email protected]

 

WWW:

 

 

www.patton.com

 

Document Number: 

 

11002U4-001 Rev. C

 

Part Number: 

 

07MD3224-IG

 

Revised: 

 

January 13, 2010

Содержание Diamond Edge 3224

Страница 1: ...G SHDSL IpDSLAM Installation Guide Sales Office 1 301 975 1000 Technical Support 1 301 975 1007 E mail support patton com WWW www patton com Document Number 11002U4 001 Rev C Part Number 07MD3224 IG...

Страница 2: ...patton com Copyright 2003 2010 Patton Electronics Company All rights reserved The information in this document is subject to change without notice Patton Electronics assumes no liability for errors th...

Страница 3: ...Temperature 15 Altitude 15 Humidity 15 Physical dimensions 15 Management services 16 LED Display 16 Approvals 17 Power Considerations 17 2 Hardware installation 19 Introduction 20 Unpacking the Model...

Страница 4: ...ration and configuration 34 PC configuration 34 Displaying the 3224 web administration pages 34 4 Operation and shutdown 39 Introduction 40 Activating the IpDSLAM 40 De activating the IpDSLAM 40 5 Mai...

Страница 5: ...remote G SHDSL modems Audience This guide is intended for the following users Operators Installers Maintenance technicians Structure This guide contains the following chapters Chapter 1 describes the...

Страница 6: ...y follow the warning instructions to avoid personal injury The shock hazard symbol and CAUTION heading indicate a potential electric shock hazard Strictly fol low the instructions to avoid property da...

Страница 7: ...t This word means to move the mouse in such a way that the tip of the pointing arrow on the screen ends up resting at the desired loca tion Click Means to quickly press and release the left or right m...

Страница 8: ...About this guide Model 3224 G SHDSL IpDSLAM Installation Guide 8...

Страница 9: ...ed by the ACTA If this equipment causes harm to the telephone network the telephone company will notify you in advance that temporary discontinuance of service may be required But if advance notice is...

Страница 10: ...above condition may not prevent degradation of service in some situations Repairs to some certified equipment should be made by an authorized maintenance facility designated by the supplier Any repai...

Страница 11: ...ew 12 Hardware overview 13 LAN 13 RS 232 control port 13 Power system 14 Central processing unit 14 G SHDSL ports 14 Alarm port 14 Temperature 15 Altitude 15 Humidity 15 Physical dimensions 15 Managem...

Страница 12: ...has sis The subscriber side connects to compatible G SHDSL modems for data rates up to 4 6 Mbps over a single pair of copper wires Expandable via optional industry standard PMC cards the IpDSLAM provi...

Страница 13: ...8 VDC power block configurations Figure 2 Model 3224 IpDSLAM features LAN Dual 10 100 Mbps Ethernet LAN ports are presented on RJ 45 connectors with an auto sensing full duplex 10Base T or 100Base T i...

Страница 14: ...uses one twisted pair 2 wires for full duplex communication The G SHDSL ports can support PPP for efficient layer 2 switching Other features include ITU T 991 2 ETSI 101 135 Programmable speeds from...

Страница 15: ...range 32 to 104 F 0 to 40 C Altitude Maximum operating altitude 15 000 feet 4 752 meters Humidity 5 to 90 relative humidity RH non condensing Physical dimensions Height 1 75 inches 4 44 cm width stand...

Страница 16: ...using a standard Web browser Figure 4 Model 3224 front panel LEDs LED Display front panel see figure 4 display the status of the four WAN ports the G SHDSL ports the Ethernet LAN port power and the a...

Страница 17: ...provals and certifications United States and Canada Safety UL60950 and CSA C22 2 No 60950 EMC FCC Part 15 Class A Telecom FCC Part 68 ACTA and Industry Canada CS03 Europe CE Mark RTTE Directive EN5502...

Страница 18: ...1 Introduction Model 3224 G SHDSL IpDSLAM Installation Guide 18 Power Considerations...

Страница 19: ...s 21 Installing the power cables AC power supply 22 Installing the power cables DC Power Supply 24 Connecting the Ethernet ports 25 Connecting the 10 100Base T Ethernet ports to an Ethernet switch or...

Страница 20: ...ll packing materials in case you need to return an item to the factory for servicing The IpDSLAM comes with the following items The Model 3224 Packet Digital Subscriber Loop Access Multiplexer IpDSLAM...

Страница 21: ...n either side of the power connector on your unit The clip will pop into place Figure 5 Attaching the cable retainer clip Grounding the Model 3224 AC and DC Power Supplies 1 Assemble a ground wire usi...

Страница 22: ...15 or 230 VAC operation By default the 3224 230 IpDSLAM is set to 230 VAC and the 3224 115 is set to 115 VAC If you need to change the voltage setting for your power supplies contact your Patton distr...

Страница 23: ...n the section Grounding the Model 3224 AC and DC Power Supplies on page 21 2 Install a power cable into an IEC 320 connector see figure 6 on page 22 3 Rotate the power cable retainer clip so it secure...

Страница 24: ...e end of each wire 3 Insert the stripped end of the positive lead into the DC input of the terminal block Tighten the screw until the power lead is firmly fastened Repeat the procedure for the negativ...

Страница 25: ...24 network and configuration ports Connecting the 10 100Base T Ethernet ports to an Ethernet switch or hub The 10 100Base T Ethernet ports see figure 9 are designed to connect to an Ethernet switch or...

Страница 26: ...mote CPE G SHDSL modems are connected to the IpDSLAM via the RJ 21X cable Consult Appen dix A Network Ports RJ 21X connector pin out in order to connect the CPE G SHDSL modems to the selected G SHDSL...

Страница 27: ...tallation is complete Refer to chapter 3 Configuring the IpDSLAM for operation on page 29 DC Units For DC units do the following Note An approved external power supply that incorporates a disconnect d...

Страница 28: ...2 Hardware installation Model 3224 G SHDSL IpDSLAM Installation Guide 28 Completing the hardware installation...

Страница 29: ...Chapter contents Introduction 30 Configuration prerequisites 30 Preparing the IpDSLAM for configuration 30 IP address quick start modification 32 Web operation and configuration 34 PC configuration 3...

Страница 30: ...terminal emulation software program such as HyperTerminalTM A PC with an Ethernet port and a WWW browser connected to the remote access server s local LAN The IP address and subnet mask for the IpDSL...

Страница 31: ...m as follows Open a terminal emulation session Enter a name for this connection Click on the Connect using pop up menu and choose the Direct to ComX option where X is the number of the COM port onto w...

Страница 32: ...s configuration Configure the Settings for Function arrow and ctrl keys act as to Terminal keys as shown in figure 15 IP address quick start modification At turn on boot up information will display on...

Страница 33: ...then press enter The 3224 will display IP address and netmask for Ethernet interfaces 3 To change the IP address for Ethernet 0 A enter option A then press enter At the prompt type the new IP address...

Страница 34: ...e next steps in configuration will be done using your web browser connected via Ethernet to the Model 3224 Consult the Model 3224 Administrator Reference Guide and Model 3224 Applications Reference Gu...

Страница 35: ...figuration 35 Model 3224 G SHDSL IpDSLAM Installation Guide 3 Configuring the IpDSLAM for operation 5 The Model 3224 Configuration Menu home page will appear see figure 16 Figure 16 Model 3224 Configu...

Страница 36: ...nfor mation pane see figure 17 The Configuration Menu contains the links to the various Model 3224 sub systems while in the Configuration information pane you can view status and other information or...

Страница 37: ...you select Record Current Configuration the 3224 stores your changes to FLASH memory Note If you want to save the configuration changes that you have made you must click on Record Current Configuratio...

Страница 38: ...3 Configuring the IpDSLAM for operation Model 3224 G SHDSL IpDSLAM Installation Guide 38 Web operation and configuration...

Страница 39: ...39 Chapter 4 Operation and shutdown Chapter contents Introduction 40 Activating the IpDSLAM 40 De activating the IpDSLAM 40...

Страница 40: ...hes indicating that the IpDSLAM is satisfied with the quality of the T1 E1 PRI signal 4 After 10 seconds the Link A Error LED extinguishes indicating that the IpDSLAM is satisfied with the network sig...

Страница 41: ...41 Chapter 5 Maintenance Chapter contents Introduction 42 Replacing a power supply 42...

Страница 42: ...e hot swappable so a defective supply can be replaced without deac tivating the IpDSLAM Do the following to replace a malfunctioning power supply Note You will need a flat tip screwdriver to perform t...

Страница 43: ...y into the IpDSLAM chassis as shown in figure 20 until the locking tabs are press ing against the chassis When that occurs push down on the locking tabs while pressing the power supply completely into...

Страница 44: ...pply 11 Place the defective power supply into the shipping container that was used to transport the replacement power supply 12 Depending on the instructions you received when you obtained your RMA nu...

Страница 45: ...r contents Introduction 46 Contact information 46 Warranty Service and Returned Merchandise Authorizations RMAs 46 Warranty coverage 46 Out of warranty service 46 Returns for credit 46 Return for cred...

Страница 46: ...e carefully tested before ship ment All of our products are backed by a comprehensive warranty program Note If you purchased your equipment from a Patton Electronics reseller ask your reseller how you...

Страница 47: ...eting a request on the RMA Request page in the Support section at www patton com By calling 1 301 975 1000 and speaking to a Technical Support Engineer By sending an e mail to returns patton com All r...

Страница 48: ...6 Contacting Patton for assistance Model 3224 G SHDSL IpDSLAM Installation Guide 48 Warranty Service and Returned Merchandise Authorizations RMAs...

Страница 49: ...49 Appendix A Network Ports RJ 21X connector pin out Chapter contents Introduction 50...

Страница 50: ...ge Tip 2 Pair 2 27 Orange White Ring 2 2 White Green Tip 3 Pair 3 28 Green White Ring 3 3 White Brown Tip 4 Pair 4 29 Brown White Ring 4 4 White Slate Tip 5 Pair 5 30 Slate White Ring 5 5 Red Blue Tip...

Страница 51: ...w Ring 18 18 Yellow Brown Tip 19 Pair 19 44 Brown Yellow Ring 19 19 Yellow Slate Tip 20 Pair 20 45 Slate Yellow Ring 20 20 Violet Blue Tip 21 Pair 21 46 Blue Violet Ring 21 21 Violet Orange Tip 22 Pai...

Страница 52: ...A Network Ports RJ 21X connector pin out Model 3224 G SHDSL IpDSLAM Installation Guide 52 Introduction...

Отзывы: