![Patton electronics 3196RC Скачать руководство пользователя страница 59](http://html1.mh-extra.com/html/patton-electronics/3196rc/3196rc_user-manual_4063045059.webp)
Using a browser to complete Model 3196RC configuration
59
Model 3196RC T-DAC User Manual
3 • Configuring the T-DAC for operation
2.
From the
Line Coding
pull-down menu (
figure 38
) select
dsx1AMI(5)
or
dsxHDB3(3)
. Most installations
will use HDB3.
Figure 38. Line Coding pull-down menu with dsx1HDB3(3) selected
3.
From the
Line Build Out
pull-down menu (
figure 39
) select
e1pulse(1)
.
Figure 39. Line Build Out pull-down menu with e1pulse(1) selected
4.
Click the
Submit Query
button to apply your line interface settings.
At this point the WAN front panel LEDs will become active. The
WAN
indicator LED should now display a
steady green light, indicating the T-DAC has synchronized with the E1 line. If the E1 line is not connected to the
3196RC, T1/E1 link pages will display the hyperlink
ALARMS PRESENT
(
figure 40
) for that T1/E1 link.
Figure 40. E1 ALARMS PRESENT indicator