3080/V24
124001UA
2-1
S
ETUP
& I
NSTALLATION
P
ATTON
E
LECTRONICS
C
O
.
I
NSTALLATION
A
ND
O
PERATIONS
M
ANUAL
Caution, Disconnect the POWER Before Removing The Cover
Vorsicht, Befor Deckung Abnehmen Mach Strom Zu.
CHAPTER 2 - SETUP AND INSTALLATION
Power Connection
Before connecting the 3080/V24 (CTS DSD-8) to a AC power source the top cover must be
installed and secured with the supplied #8-32 screws. The unit is supplied with a 110/220VA
voltage switch, turn the switch with a coin or screw driver to the appropriate voltage for your
country. If the unit is set to 110V insure that
the fuses are 0.16A Slow Blow (Little Fuse
218.160). For 220V operation use 0.08A
(Little Fuse 218.080) Slow Blow fuses.
EXAMPLE: United States of America; set
to 110VA. The unit is supplied with a IEC
power connector next to the voltage select
switch, plug the power cord into the
connector until it is firmly seated. You
may now connect the power cord into
your AC outlet.
Factory Configuration Switch Settings
The 3080/V24 (CTS DSD-8) is configured prior to shipment with the switches set to the
following default positions:
Switch 27 - 6
OFF
, 1,2,3,4 and 5
ON
.
TX Clock Source = Master, pin 15
Chassis Ground not connected to Signal Ground
Switch 28 - 4 and 5
OFF
, 1,2,3 and 6
ON
.
RX Clock Source = Master
Anti-Stream timer = 16K bits
Switch 29 - 1, 2 and 4 to
OFF
, 3,5 and 6
ON
.
No Data Time Out = 2048 bits
Anti-Stream = Enabled
Broadcast Data to Sub-Channels
Sub-Channel Activity Indicated by Interface Control (RTS/DCD)
110 / 220VA Switch
Fuse Drawer
MASTE R DTE/ DCE
IEC Power Connector
110 22