background image

29

Remote Port: 23

Remote Password: (UNDEFINED)

Remote User ID: (UNDEFINED)

Session Termination Character: 0x04 (or preferred)

User Database Settings

user database empty! (or add users and corresponding passwords and 
privileges)

RawTCP Operation

In the typical RawTCP application (see Figure 7), the user has a need to 
connect a network enabled software application to a remote serial device 
over the LAN for standard operation of the device.  To enable the soft-
ware application to communicate with the remote serial device, the 
Model 2120 is usually assigned a static IP Address and the IP Address is 
configured within the software application.  When the software applica-
tion is launched, it sends data in TCP packets over the LAN to the IP 
Address of the Model 2120.  When received, the Model 2120 converts 
the packets to asynchronous data and forwards the data to the device 
connected to the serial interface.  The serial device sends asynchronous 
data back to the Model 2120 and the Model 2120 converts the data into 
TCP packets and sends it over the LAN back to the originating location/
application to complete the cycle.  In this type of application, the Raw-
TCP connection between the software application and Model 2120 is 
configured so that is does not timeout/disconnect.

Note

Legacy software applications that are not network enabled will 

require a Comm Port Redirector application to communicate 
with the Model 2120 and the remote serial device over the LAN.  
A Comm Port Redirector is used to map serial communication 
ports to the IP address and port number of the 2120 connected 
to the remote serial device. This application resides on the com-
puter hosting the legacy software application and basically tricks 
the legacy application into packetizing the asynchronous data 
into TCP packets and sending the data over the LAN to the IP 
Address of the remote 2120/device, thus creating a transparent 
serial connection.

Содержание 2120

Страница 1: ...USER MANUAL MODEL 2120 RS 232 Single Port Terminal Server SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 Part 07M2120 UM Doc 08302U2 001 Rev D Revised 10 27 06 An ISO 9001 Certified Company...

Страница 2: ...3 2 Software Configuration 16 Model 2120 Software Command System 17 Model 2120 Help Menu Command Hierarchy 17 Entering Commands 19 Activating Configuration Commands 19 3 3 Default Configuration Parame...

Страница 3: ...2 AC Power Connection 49 AC Power Supply 100 240VAC 50 DC Power Supply 36 60VDC 50 5 0 Operation 51 5 1 LED Status Indicators 51 Rear Panel LEDs 51 Top Panel LEDs 52 5 2 Flow Control And Session Cont...

Страница 4: ...A 16 Weight 58 B Model 2120 Single Port Terminal Server Software Command Definitions 59 B 1 Activate Image Commands 59 B 2 Boot Commands 59 B 3 Configure Commands 59 B 4 EIAONCLOSE Commands 69 B 5 FT...

Страница 5: ...ms by the user 1 1 FCC INFORMATION This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to pro...

Страница 6: ...repairs must be returned freight prepaid and insured to Patton Electronics All returns must have a Return Mate rials Authorization number on the outside of the shipping container This number may be o...

Страница 7: ...indicators RS 232 serial connection via DB 25 male and female DB 9 male and female and RJ 45 female connector options 802 3 10Base T LAN connection via RJ 45 female connector Ethernet Link and System...

Страница 8: ...e serial interface with Ethernet con nectivity using either PPP or SLIP protocols Proxy ARP provides the device connected to the serial interface with a virtual Ethernet connection DHCP enable disable...

Страница 9: ...omatic connection request to a remote device Permits incoming connection requests from remote devices on the serial interface Selectable frequency in seconds of the automatic connection requests to re...

Страница 10: ...Ability to disable the user interface at the serial interface when using Telnet or Raw TCP Selectable unit management inactivity timeout minutes with disable option Ability to change the preset syste...

Страница 11: ...etting of each individual serial interface related parameter Ability to view all current Raw TCP related parameters Ability to view current setting of each individual Raw TCP related parameters Abilit...

Страница 12: ...tivity across the LAN is provided using Tel net TCP Raw TCP SLIP or PPP protocols The versatile and feature rich Model 2120 can literally be used in thousands of different applications and environment...

Страница 13: ...al interface is sent to the remote device using the Telnet TCP protocol Asynchronous data received from the Telnet TCP connection is sent to the device connected to the Model 2120 serial interface Whe...

Страница 14: ...curity is enabled the user may connect from a remote PPP client through a modem connected to the serial port of the Model 2120 and receive transmit data over the LAN The Model 2120 uses an integrated...

Страница 15: ...rposes only To access switch set SW1 use a small flat blade screwdriver to open the Model 2120 s case as shown in Figure 3 Figure 2 Switch set SW1 location Figure 3 Opening the Model 2120 case To conf...

Страница 16: ...s switch is not used and must remain in the OFF position Switch 4 Not Used This switch is not used and must remain in the OFF position 3 2 SOFTWARE CONFIGURATION The Model 2120 features a menu driven...

Страница 17: ...et boot Boot System configure Configure Parameters eiaconclose EIA232 Connection Close ftp FTP To Remote Device ping Ping Remote Device rawtcp Raw TCP To Remote Device show Show Parameters and Statist...

Страница 18: ...18 Figure 5 Model 2120 Help Menu Command Hierarchy...

Страница 19: ...for that menu Thus shortcuts are permitted when entering commands The following examples show how shortcut commands can be used to enter the same configure and boot commands as listed above TS c e i d...

Страница 20: ...ial Interface IP Address 5 5 5 5 Parity none Serial Interface Protocol Telnet Stop Length 1 bits Serial Interface Subnet Mask 255 255 255 0 PPP Defaults PPP DHCP Enable no Peer IP Address Use Enable n...

Страница 21: ...utes Prompt TS Unit Subnet Mask 255 255 255 0 User Database Defaults user database empty Note To reset the Model 2120 software to factory default settings set internal dip switch 1 to the ON position...

Страница 22: ...t version TS Note If you are unable to connect with the Model 2120 and you have rechecked your terminal emulation settings it is recommended that a configuration reset to factory defaults be performed...

Страница 23: ...0 0 Help Menu Display Enable yes IP Address Active 192 168 200 1 IP Address Configured 192 168 200 1 MAC Address 0x00A0BA000D95 Management Enable yes Management Inactive Timeout min 15 Management Port...

Страница 24: ...ws Name Server Address 0 0 0 0 Secondary Domain Name Server Address 0 0 0 0 Secondary Windows Name Server Address 0 0 0 0 Receive Async Control Character Map 0xFFFFFFFF Transmit Async Control Characte...

Страница 25: ...indows Command Mode on a computer that can communi cate over the LAN 1 From the Windows Run prompt at your computer type command and click OK 2 At the DOS prompt Telnet into the 2120 by typing telnet...

Страница 26: ...elated operating systems and applica tions Telnet TCP Operation In the typical Telnet TCP application see Figure 6 the user has a need to remotely connect to a serial device located on the LAN for adm...

Страница 27: ...ress IP Address of Default Gateway of 2120 LAN DHCP Enable no IP Address Configured IP Address Assigned by Network Admin MAC Address Factory Assigned Management Enable yes or preferred Management Inac...

Страница 28: ...op Length 1 or setting required by serial device Subnet Mask Configured Same as System Subnet Mask EIA232 PPP Settings DHCP Enable no Peer IP Address Use Enable no Peer Name Server Address Use Enable...

Страница 29: ...device connected to the serial interface The serial device sends asynchronous data back to the Model 2120 and the Model 2120 converts the data into TCP packets and sends it over the LAN back to the or...

Страница 30: ...ess IP Address of Default Gateway of 2120 LAN DHCP Enable no IP Address Configured IP Address Assigned by Network Admin MAC Address Factory Assigned Management Enable yes or preferred Management Inact...

Страница 31: ...or setting required by serial device Subnet Mask Configured Same as System Subnet Mask EIA232 PPP Settings DHCP Enable no Peer IP Address Use Enable no Peer Name Server Address Use Enable no Primary...

Страница 32: ...the connection is made between the PPP dial up peer and the modem the Model 2120 serial interface will typically obtain its operating IP address from an active DHCP server on the LAN and then establi...

Страница 33: ...PPP Terminal Server System Settings Boot Message Display Enable no Default Gateway IP Address IP Address of Default Gateway of 2120 LAN DHCP Enable no IP Address Configured IP Address Assigned by Net...

Страница 34: ...Inactive Timeout min 15 or preferred IP Address Configured 8 8 8 8 default active address obtained using DHCP Parity none or setting required by modem Protocol ppp Stop Length 1 or setting required by...

Страница 35: ...ake this connection the user typically uses a dial up modem with standard POTS line and launches a SLIP application to connect with a dial up or ISDN modem connected to the LAN Once the connection is...

Страница 36: ...is usually terminated once the user is finished accessing the LAN Internet Figure 9 SLIP Terminal Server System Settings Boot Message Display Enable no Default Gateway IP Address IP Address of Defaul...

Страница 37: ...red by modem Flow Control none or setting required by modem Inactive Timeout min 15 or preferred IP Address Configured Serial Interface IP Address Assigned By Network Admin Parity none or setting requ...

Страница 38: ...ges 3 7 USER DATABASE The Model 2120 features a flexible user database with security for up to 64 users This enables security access to the Model 2120 serial inter face and administrative management o...

Страница 39: ...user to access only the administrative management and configuration status functions of the Model 2120 over the LAN via Telnet session Both The Both privilege provides a user with both User and Admin...

Страница 40: ...em prompt TS show userdatabase all Enter user database empty TS Deleting A Single User Deleting a single user is accomplished by executing the following com mands at the 2120 command system prompt TS...

Страница 41: ...all Enter User Database john 123abc user tom 98lk12 both Total Users 2 TS configure userdatabase modifyuser tom 98lk12 admin Enter TS configure activate Enter activate is complete TS Verifying that th...

Страница 42: ...e activate Enter activate is complete TS For applications that require a static IP address for the Model 2120 unit an assigned IP address is obtained from your Network Administrator and is configured...

Страница 43: ...face IP address from the PPP client device connected to the serial interface In this scenario every time a PPP client establishes a PPP connection the Model 2120 will use the IP address provided by th...

Страница 44: ...S configure activate activate is complete TS 3 9 NAME SERVERS When operating in PPP mode and accessing the Internet through the Model 2120 the several options are available and supported for Internet...

Страница 45: ...e connected to the serial interface Every time a PPP establishes a connection the Model 2120 will use the name server addresses pro vided by the PPP instead of the other configured name server address...

Страница 46: ...odel 2120 You must have a valid IP address assigned to the Model 2120 and the Model 2120 must be connected to the LAN You must have an FTP Client i e Windows Command Mode on a computer that can commun...

Страница 47: ...erational software on your 2120 You must have a valid IP address assigned to the Model 2120 and the 2120 must be connected to the LAN with Internet access You must have an FTP Client i e Windows Comma...

Страница 48: ...type quit and press Enter to return to the TS prompt 8 At the TS prompt type activateimage and press Enter 9 Once the image is activated you will lose your connection to the Model 2120 To verify new s...

Страница 49: ...evice The RJ 45 connector on the serial side allows for a convenient connection with a patch cable not provided with 2120 to RS 232 control ports and other devices with RJ 45 serial ports The 2120 con...

Страница 50: ...ck and red leads plug into a DC source nominal 48VDC and the barrel power connector plugs into the barrel power sup ply jack on the 2120 see Figure 11 Figure 11 Connecting DC Power to the 2120 DC Powe...

Страница 51: ...120 Single Port Terminal Server 5 1 LED STATUS INDICATORS The Model 2120 features seven top panel LEDs and two rear panel LEDs The figures below show the their position A description of each LED follo...

Страница 52: ...ed Telnet and Raw TCP operation only 3 Blinks TCP Connection Not Established 4 Blinks DB25 Data Rate Is 50 BPS 5 Blinks DB25 Data Rate Is 75 BPS 6 Blinks DB25 Data Rate Is 110 BPS 7 Blinks DB25 Data R...

Страница 53: ...120 DCE will turn CTS ON to allow the DTE to transmit data and OFF to stop the DTE from sending data before the 2120 receive buffers overflow The opposite is true when the 2120 is configured for DTE o...

Страница 54: ...nal Ready and DSR Data Set Ready control signals are used for terminating a SLIP or PPP session If the user is configured for DTE operations and wishes to disconnect the session the DTE will turn DTR...

Страница 55: ...s of remote device Enter pinging Reply from IP address of remote device bytes 64 SN 0 TTL 128 time 10msec Reply from IP address of remote device bytes 64 SN 1 TTL 128 time 10msec Reply from IP address...

Страница 56: ...e telnet command TS telnet IP address of remote device Enter or t IP address of remote device Enter connecting Telnet Session Started Display ARP Table The za command allows the display of the Model 2...

Страница 57: ...e selectable A 4 RS 232 STATUS INDICATORS TXD RXD DTR RTS CTS DCD and Power A 5 ETHERNET INTERFACE RJ 45 female connector A 6 ETHERNET STANDARD 10Base T IEEE 802 3 A 7 SYSTEM STATUS INDICATORS Etherne...

Страница 58: ...2 TEMPERATURE 32 122 F 0 50 C A 13 ALTITUDE 0 to 15 000 feet 0 to 4 572 meters A 14 HUMIDITY Up to 95 non condensing A 15 DIMENSIONS 3 5L X 2 1W X 0 78H in 9 0L X 5 3W X 1 9H cm A 16 WEIGHT 0 2 lbs 0...

Страница 59: ...tivated session is lost Accessibility N A Default N A Valid Entries N A Note Command will not work unless SW has been downloaded to unit B 2 BOOT COMMANDS boot Remotely performs a soft boot of the 212...

Страница 60: ...alid Entries N A Note Needs to be entered first in all configure eia232 command strings configure eia232 interface Returns the Configure EIA232 Interface Help Menu Accessibility N A Default N A Valid...

Страница 61: ...interface for an unlimited period of time configure eia232 interface ipaddrcfg X Sets the static IP address used to conduct PPP or SLIP operations Accessibility READ WRITE Default 8 8 8 8 Valid Entri...

Страница 62: ...ct PPP or SLIP operations configure eia232 nvt echoena X Echo Enable configure eia232 nvt endofrecordena X End Of Record Enable configure eia232 nvt linemodeena X Line Mode Enable configure eia232 nvt...

Страница 63: ...id Entries yes no configure eia232 ppp pridnsaddr X Sets the address of the primary DNS used to support DNS address exchange with the client device connected to the serial interface Accessibility READ...

Страница 64: ...configure eia232 rawtcp_telnet confromlocena X Permits the automatic connection request to a remote device over the LAN Accessibility READ WRITE Default no Valid Entries yes no Note To activate the a...

Страница 65: ...remidlediscto X Remote idle disconnect timeout sec configure eia232 rawtcp_telnet remip X Sets the destination IP address used when automatic connection requests are sent to a remote device over the L...

Страница 66: ...or desired session termination character configure eia232 rawtcp_telnet uicmdena X User Interface Command Enable configure ipfwd ipfwdena X IP forwarding enable configure ipfwd natipaddr X NAT IP addr...

Страница 67: ...a DHCP Server as the IP Address of the 2120 unit This feature will not function unless there is an active DHCP Server on the LAN configure system helpmenudispena X Help menu display enable configure s...

Страница 68: ...e and allow a Telnet session for an unlimited period of time configure system manport X Management port configure system prompt X Sets system command prompt Accessibility READ WRITE Default TS Valid E...

Страница 69: ...ies user name up to 32 characters configure userdatabase modifyuser X Modifies the password or privilege of individual users in the user data base Accessibility N A Default N A Valid Entries user name...

Страница 70: ...y N A Default N A Valid Entries N A Note Needs to be entered first in all show command strings show eia232 Returns the Show EIA232 Help Menu Accessibility N A Default N A Valid Entries N A Note Needs...

Страница 71: ...tes for closing an inactive connection to the serial interface Accessibility READ ONLY show eia232 interface ipaddactive Returns the current active IP address for the serial interface Accessibility RE...

Страница 72: ...terface subnetactive Returns the current active Subnet Mask for the serial interface Accessibility READ ONLY Note This will match the Subnet Mask of the LAN where the active serial interface IP addres...

Страница 73: ...The bound state should appear when DHCP is successfully operating show eia232 ppp dhcppassedtime Returns the amount of time in seconds since the lease on the PPP related IP address started Accessibil...

Страница 74: ...d by the DHCP Server resides 1 show eia ppp dhcpdefgateway DHCP Default Gateway 2 show eia ppp dhcphwaddr DHCP Hardware Address 3 show eia ppp fcslength FCS Length show eia232 ppp ipconstate Returns t...

Страница 75: ...sent starting stopped stopping show eia ppp pingena Ping Enable show eia232 ppp pridnsaddr Returns the current address of the primary DNS used to support DNS address exchange with the client device co...

Страница 76: ...p_telnet all Returns all current EIA232 Raw TCP Telnet settings Accessibility READ ONLY show eia232 rawtcp_telnet confromlocena Returns current Connection From Local Enable setting Accessibility READ...

Страница 77: ...r Returns current Session Termination Character setting Accessibility READ ONLY show eia232 rawtcp_telnet tcpconstate Returns current TCP Connection State Accessibility READ ONLY Default listen Possib...

Страница 78: ...ault select Possible States bound initialize rebind renew request select Note The bound state should appear when DHCP is successfully operating show system dhcppassedtime Returns the amount of time in...

Страница 79: ...ask of the LAN where the active unit IP address assigned by the DHCP Server resides show system dhcpdefgateway DHCP Default Gateway show system helpmenudispena Help Menu Display Enable show system ipa...

Страница 80: ...sibility READ ONLY show system swversion Returns current software version Accessibility READ ONLY show userdatabase Returns the User Database Help Menu Accessibility N A Default N A Valid Entries N A...

Страница 81: ...erm Ready DTR 20 8 DCD Data Carrier Detect Output Output Ring Indicator RI 22 DIRECTION DCE STANDARD SETTING DIRECTION Output Data Set Ready DSR 6 1 DCD Data Carrier Detect Output Input Request to Sen...

Страница 82: ..._________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ ________...

Страница 83: ..._________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ ________...

Страница 84: ...______________ _________________________________________________________ _________________________________________________________ _________________________________________________________ ___________...

Отзывы: