manualshive.com logo in svg
background image

APPENDIX A

PATTON MODEL 2035 SPECIFICATIONS

Interface: 

Asynchronous., RS-232C compatible

Connectors:

Serial, DB-25F; parallel, Centronics 36 pin 
M

Cables:

Six foot (1.8m) integral cable 

Data Rates:

1.2 - 115.2 Kbps

LED:  

LED displays status and operating condition

Power Supply: 

None required; uses power from RS-232C
interface

Data Format: 

7 or 8 bits; 1 or 2 stop bits; even, odd or no 
parity

Temperature Range: 0-60

°

C (32-140

°

F)

Altitude:  

0-10,100 feet

Humidity:  

5 to 95% non-condensing

Dimensions:  

2.62" x 1.26" x .76"

Weight:  

2 oz. (56.8 grams)

9

10

APPENDIX B

PATTON MODEL 2035 INTERFACE CONNECTIONS

36 PIN CENTRONICS PARALLEL PORT CONNECTIONS

Pin

Description

Direction

1

Strobe

Output

2

Data bit 0

3

Data bit 1

4

Data bit 2

5

Data bit 3

6

Data bit 4

7

Data bit 5

8

Data bit 6

9

Data bit 7

10

Acknowledge

Input (active low)

11

Busy

Input (active high)

12

Paper end

13

Select

18

+5 volts

32

Error
(16, 17, 19, 20, 21, 22, 23, 24, 

25, 26, 27, 28, 29, 30, 33, 36)

Note:  All other pins are unconnected

DB-25 SERIAL PORT CONNECTIONS

Pin

Name

Description

1

FG

Connected to pin 7 with optional jumper

2

TXD

Serial Transmit Data; also used as a 

power source

3

RXD

Serial Receive Data; also used as a power

source 

4

RTS

Request to Send; also used as a power source

5

CTS

Clear to Send; also used as a power source

6

DSR

Data Set Ready; also used as a power source

7

SG

Signal Ground

8

DCD

Carrier Detect; also used as a power source

9

+V in

Used as a power source

20

DTR

Data Terminal Ready; also used as a power

source

Note:  All other pins are unconnected

}

I/O

}

Ground

Содержание 2035-25M

Страница 1: ...35 25M Parallel to Serial Serial to Parallel Interface Converters SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2035 B Doc 102051UB Revised 6 27 97 C E R T I F I...

Страница 2: ...which are designed to provide reasonable protection from such interference in a commercial installation However there is no guarantee that interference will not occur in a particular installation If...

Страница 3: ...75 1007 http www patton com or support patton com 2 1 FEATURES Converts parallel data to serial data and vice versa Automatic parallel and serial sensing and selection Automatic DCE DTE sensing and se...

Страница 4: ...ncy and Data Rate Switches 6 through 8 determine the frequency and data rate The following chart shows the settings that may be used 6 1 200 OFF OFF ON 2 400 ON OFF ON 4 800 ON ON OFF 9 600 OFF ON ON...

Страница 5: ...5 1 LED STATUS MONITORS The Model 2035 features an easy to read status LED that glows red to indicate the condition of the transmission line Figure 1 shows the location of the LED The following chart...

Страница 6: ...Output 2 Data bit 0 3 Data bit 1 4 Data bit 2 5 Data bit 3 6 Data bit 4 7 Data bit 5 8 Data bit 6 9 Data bit 7 10 Acknowledge Input active low 11 Busy Input active high 12 Paper end 13 Select 18 5 vo...

Страница 7: ...Sales E mail sales patton com Support E mail support patton com Phone Sales 301 975 1000 Phone Support 301 975 1007 Fax 301 869 9293 Mail Patton Electronics Company 7622 Rickenbacker Drive Gaithersbu...

Отзывы: