Inverted Data and Control Signals
Position JP1 and JP2 horizontally on the jumper posts to select
inverted data and control signals. Figure 5 shows the position of the
jumpers on the pc board. Table 4 shows the relative signal levels.
Inverted Data and Non-Inverted Control Signals
Position JP1 horizontally top jumper posts and remove JP2 to
select inverted data and non-inverted control signals. Figure 6 shows
the position of the jumpers on the pc board. Table 5 shows the relative
signal levels.
7
Inverted Control and Non-Inverted Data Signals
Position JP2 horizontally on bottom jumper posts to select inverted
control and non-invert data signals. Figure 7 shows the position of the
jumpers on the pc board. Table 6 shows the relative signal levels.
8
Signal Level
Data Signals
Control Signals
0.0 to 0.4 Volts
space
inactive
2.4 - 5.0 Volts
mark
active
Table 6.
Inverted Control, Non-Inverted Data Signals
Signal Level
Data Signals
Control Signals
0.0 to 0.4 Volts
mark
active
2.4 - 5.0 Volts
space
inactive
Table 5.
Inverted Data, Non-Inverted Control Signals
JP1
JP2
Figure 6
: Inverted Data and Non-Inverted Control Signal Jumpers
JP1
JP2
Figure 7
: Inverted Control and Non-Inverted Data Signal Jumpers
Signal Level
Data Signals Control Signals
0.0 to 0.4 Volts
mark
inactive
2.4 - 5.0 Volts
space
active
Table 4.
Inverted Data and Control Signals
JP1
JP2
Figure 5
: Inverted Data and Control Signal Jumpers