Functions of LEDs are as follows:

Fiber

The green Fiber LED indicates reliable data on the fiber side.

E1

The green E1 LED indicates reliable data on the G.703/G.704 
side.

LOS

The red LOS indicates that syncronization between modems        
has not been established. Blinking red LOS LED indicates the 
presense of coding errors. 

NS

The red NS LED indicates that the signal on the fiber side is 
too weak to be detected. That could be due to any of the following 
reasons:
- break in the fiber optic cable
- length of the fiber optic cable exceeds the maximum distance
- problem with Fiber LED.

ER

Flashing red ER LED indicates errors in 511 test pattern

TM

The yellow TM LED indicates that the modem is in a test mode     

(Local/Remote Loopback or 511/511E test pattern). Opaque LED 
indicates normal operation. 

13

5.3  TEST MODES

The following section describes the test patterns and loopbacks

used in the Model 1193. The Model 1193 offers V.54 compliant
local/remote loopback tests, plus a built-in V.52 BER test pattern gener-
ator to evaluate the condition of the modems and the communication
link.  These tests can be activated physically from the front panel.  

5.3.1 Local Loopback

The local loopback test checks the operation of the local Model

1193, and is performed separately on each unit. The following section
describes how to perform a local loopback test between the Network
and a local connection. 

Any data sent to the local Model 1193 in this test mode will be

echoed (returned) back to the user (see Figure 11 below). If two Model
1193 units are linked when the LAL is activated, data sent from the
remote modem will also be looped back to the remote terminal equip-
ment.

To test the local connection, follow these steps:

1. Activate LAL by moving the front panel toggle switch UP to "Local".
Once the Local Loopback is activated, the Model 1193 transmit output
will be connected to its own receiver. The TM LED will light up.  

2. Perform a BER (Bit Error Rate) test on each unit using a separate
BER tester. If the BER test equipment indicates no faults but the data
indicates a fault, follow the manufacturer's checkout procedures for the
data terminal. Also check the interface cable between the terminal and
the Model 1193. The BER test can also be performed using a built-in
511/511E pattern generator. (See section 5.3.3 on how to use the built-in
511/511E pattern generator.)

3. Upon completion of the LAL test, return the front panel switch to
NORMAL position. The TM LED should turn off.

14

Figure 11.

Local loopback diagram

G.703/G.704

Network

Содержание 1193

Страница 1: ...3 Single Mode Fiber Modem with Fixed G 703 G 704 Interface Part 07M1193 UM Doc 01713U2 001 Rev C Revised 10 25 06 SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com An ISO 90...

Страница 2: ...ties expressed or implied and the installation or use of this product shall be deemed an acceptance of these terms by the user 1 1 RADIO AND TV INTERFERENCE The Model 1193 generates and uses radio fre...

Страница 3: ...fiber Single mode fiber with max distance 50km 31 miles Two fiber connection options available FC or SC 120 Ohm RJ 48C and 75 Ohm dual coax G 703 G 704 termina tions Clocking options Internal Network...

Страница 4: ...de of the 1193 S1 S2 Setting Description On On Internal Transmit clock generated internally On Off Receive Recover Transmit clock derived from the line Off On Network Transmit clock derived from G 703...

Страница 5: ...e set to OFF 3 1 2 Select RJ 48C or BNC Connectors The Model 1193 is shipped configured for use with a BNC connec tion to the G 703 G 704 Network If your Network connection is using BNC skip this sect...

Страница 6: ...ia dual coaxial cable see Figure 7 below to make the proper connections 4 2 CONNECT THE FIBER INTERFACE The Model 1193 is designed to be connected to another Model 1193 The Model 1193 supports communi...

Страница 7: ...onfigured and installed it should operate transparently This section describes power up LED status monitors and the built in loopback test modes 5 1 POWER UP To apply power to the Model 1193 read Sect...

Страница 8: ...The local loopback test checks the operation of the local Model 1193 and is performed separately on each unit The following section describes how to perform a local loopback test between the Network a...

Страница 9: ...DL test return the front panel switch to NORMAL position The TM LED should turn off on both local and remote units 5 3 3 The V 52 Test Pattern Generator To use the V 52 BER test in conjunction with th...

Страница 10: ...ed NS LED indicates that the sig nal on the fiber side is too weak to be detected ER Flashing red ER LED indicates errors in 511 test pattern TM The yellow TM LED indicates that modem is in a test mod...

Страница 11: ...100 240VAC 5V 5 reg DC 2A Universal Input Adapter 0805EUR European Power Cord CEE 7 A 0805UK United Kingdom Power Cord D 0805US American Power Cord K 0805AUS Australia New Zealand Power Cord C 0805DE...

Отзывы: