The Model 1193 is equipped with eight DIP switches, which allow

configuration of the unit for a wide variety of applications.  This section
describes location of the switches and explains all possible configura-
tions.

3.1  CONFIGURING THE HARDWARE DIP SWITCHES 

The 8 external dip switches are accessible from the underside of

the Model 1193 (See Figure 2 below).   

Figure 3 shows the orientation of the DIP switches in the

“ON” and “OFF” positions.  

5

Figure 3. 

Close up of configuration switches 

Figure 2.

Underside of Model 1193, showing location of the DIP switches

Front

Rear

On

Off

3.1.1 Configure the Model 1193

Switches S1 through S8 may be used to configure clocking modes

and line coding.  Default settings of the switches are shown in the table
below. A description of the switch options follows the table.

Switches S1 and S2: Clock Mode

Use switches S1 and S2 to determine clock mode of the 1193.

S1    S2    Setting                 Description

On

On

Internal

Transmit clock generated internally

On

Off

Receive Recover   Transmit clock derived from the line 

Off

On     Network

Transmit clock derived from G.703/G.704 

equipment interface

Off

Off

Internal use only

Switch S3 and S4:  Line Coding Options

Use switches S3 and S4 to determine whether the G.703/G.704 line

coding is HDB3 or AMI (for older telecommunications equipment). The
line coding must be the same line coding prescribed by the NAP
(Network Access Provider).  Most applications will use HDB3.

High Density Bipolar 3 (HDB3)

:  In HDB3 coding, the transmitter

deliberately inserts a bipolar violation when excessive zeros in the
data stream are detected. The receiver recognizes these special vio-

6

OFF

ON

S1

Note: The Model 1193 units are intended to work in pairs. Set the clock
modes for the Model 1193 units with one end of the link set for receive
recover and the other end set for either internal or network.

Position

Function

Default Setting

S1

Clock Source

ON

S2

Clock Source

ON

S3

Line

OFF

S4

Coding

OFF

S5
S6

Reserved for Future Applications

OFF

S7
S8

}

}

Internal 
Clock

HDB3

Содержание 1193

Страница 1: ...3 Single Mode Fiber Modem with Fixed G 703 G 704 Interface Part 07M1193 UM Doc 01713U2 001 Rev C Revised 10 25 06 SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com An ISO 90...

Страница 2: ...ties expressed or implied and the installation or use of this product shall be deemed an acceptance of these terms by the user 1 1 RADIO AND TV INTERFERENCE The Model 1193 generates and uses radio fre...

Страница 3: ...fiber Single mode fiber with max distance 50km 31 miles Two fiber connection options available FC or SC 120 Ohm RJ 48C and 75 Ohm dual coax G 703 G 704 termina tions Clocking options Internal Network...

Страница 4: ...de of the 1193 S1 S2 Setting Description On On Internal Transmit clock generated internally On Off Receive Recover Transmit clock derived from the line Off On Network Transmit clock derived from G 703...

Страница 5: ...e set to OFF 3 1 2 Select RJ 48C or BNC Connectors The Model 1193 is shipped configured for use with a BNC connec tion to the G 703 G 704 Network If your Network connection is using BNC skip this sect...

Страница 6: ...ia dual coaxial cable see Figure 7 below to make the proper connections 4 2 CONNECT THE FIBER INTERFACE The Model 1193 is designed to be connected to another Model 1193 The Model 1193 supports communi...

Страница 7: ...onfigured and installed it should operate transparently This section describes power up LED status monitors and the built in loopback test modes 5 1 POWER UP To apply power to the Model 1193 read Sect...

Страница 8: ...The local loopback test checks the operation of the local Model 1193 and is performed separately on each unit The following section describes how to perform a local loopback test between the Network a...

Страница 9: ...DL test return the front panel switch to NORMAL position The TM LED should turn off on both local and remote units 5 3 3 The V 52 Test Pattern Generator To use the V 52 BER test in conjunction with th...

Страница 10: ...ed NS LED indicates that the sig nal on the fiber side is too weak to be detected ER Flashing red ER LED indicates errors in 511 test pattern TM The yellow TM LED indicates that modem is in a test mod...

Страница 11: ...100 240VAC 5V 5 reg DC 2A Universal Input Adapter 0805EUR European Power Cord CEE 7 A 0805UK United Kingdom Power Cord D 0805US American Power Cord K 0805AUS Australia New Zealand Power Cord C 0805DE...

Отзывы: