Functions of LEDs are as follows:

Fiber

The green Fiber LED indicates reliable data on the fiber side

E1

The green E1 LED indicates reliable data on the G.703/G.704 
side

LOS

The red LOS indicates that syncronization between modems
has not been established. Blinking red LOS LED indicates the 
presense of coding errors 

NS

The red NS LED indicates that the signal on the fiber side is 
too weak to be detected, which can be due to any of the fol-
lowing reasons:
- break in the fiber optic cable
- length of the fiber optic cable exceeds the maximum dis-

tance

- problem with Fiber LED.

ER

Flashing red ER LED indicates errors in 511 test pattern

TM

The yellow TM LED indicates that modem is in a test mode     

(Local/Remote Loopback or 511/511E test pattern).  Opaque 
TM indicates normal operation.

13

5.3  TEST MODES

The following section describes the test patterns and loopbacks

used in the Model 1186. The Model 1186 offers V.54 compliant
local/remote loopback tests, plus a built-in V.52 BER test pattern gener-
ator to evaluate the condition of the modems and the communication
link.  These tests can be activated physically from the front panel.  

5.3.1 Local Loopback

The local loopback test checks the operation of the local Model

1186, and is performed separately on each unit. The following section
describes how  to perform a local loopback test between the Network
and a local connection. 

Any data sent to the local Model 1186 in this test mode will be echoed
(returned) back to the user (see Figure 11). If two Model 1186 units are
linked when the LAL is activated, data sent from the remote modem will
also be looped back to the remote terminal equipment.

To test the local connection, follow these steps:

1. Activate LAL by moving the front panel toggle switch UP to "Local".
Once the Local Loopback is activated, the Model 1186 transmit output
will be connected to its own receiver. The TM LED will light up.  

2. Perform a BER (Bit Error Rate) test on each unit using a separate
BER tester. If the BER test equipment indicates no faults, but the data
indicates a fault, follow the manufacturer's checkout procedures for the
data terminal. Also, check the interface cable between the terminal and
the Model 1186. The BER test can also be performed using a built-in
511/511E pattern generator. (See section 5.3.3 on how to use the built-in
511/511E pattern generator.)

3. Upon completion of the LAL test, return the front panel switch to the
NORMAL position. The TM LED should turn off.

14

Figure 11.

Local Loopback Diagram

G.703/G.704

Network

Содержание 1186

Страница 1: ...Mode Fiber Modem with Fixed G 703 G 704 Interface Part 07M1186 UM Doc 01716U2 001 Rev C Revised 10 25 06 SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com C E R T I F I E D...

Страница 2: ...limited to the following lost profits lost savings and incidental or consequen tial damages arising from the use of or inability to use this product Patton Electronics specifically disclaims all other...

Страница 3: ...3 G 704 terminations Clocking Options Internal Network G 703 G 704 or Receive Recover fiber link Optional AMI or HDB3 G 703 G 704 data coding Six Front Panel LED status indicators Fiber line E1 line L...

Страница 4: ...S2 Setting Description On On Internal Transmit clock generated internally On Off Receive Recover Transmit clock derived from the line Off On Network Transmit clock derived from G 703 G 704 equipment...

Страница 5: ...witches S5 through S8 are reserved for future applications and should be set to OFF 3 1 2 Select RJ 48C or BNC Connectors The Model 1193 is shipped configured for use with a BNC connec tion to the G 7...

Страница 6: ...75 ohm dual coax G 703 G 704 Network inter face If your G 703 G 704 Network terminates via dual coaxial cable 10 use the diagram below to make the proper connections The connec tor pinout and signals...

Страница 7: ...y This section describes power up reading the LED status monitors and using the built in loopback test modes 5 1 POWER UP To apply power to the Model 1186 first be sure that you have read Section 4 3...

Страница 8: ...The local loopback test checks the operation of the local Model 1186 and is performed separately on each unit The following section describes how to perform a local loopback test between the Network a...

Страница 9: ...e RDL test return the front panel switch to the NORMAL position The TM LED should turn off on both local and remote units 5 3 3 V 52 Test Pattern Generator To use the V 52 BER test in conjunction with...

Страница 10: ...errors NS The red NS LED indicates that the sig nal on the fiber side is too weak to be detected ER Flashing red ER LED indicates errors in 511 test pattern TM The yellow TM LED indicates that modem...

Страница 11: ...100 240VAC 5V 5 reg DC 2A Universal Input Adapter 0805EUR European Power Cord CEE 7 A 0805UK United Kingdom Power Cord D 0805US American Power Cord K 0805AUS Australia New Zealand Power Cord C 0805DEN...

Отзывы: