Patton electronics 1186 Скачать руководство пользователя страница 1

USER
MANUAL

MODEL 1186

Multi-Mode Fiber Modem with
Fixed G.703/G.704 Interface

Part# 07M1186-UM
Doc# 01716U2-001,
Rev. C
Revised 10/25/06

SALES OFFICE
(301)975-1000
TECHNICAL SUPPORT
(301)975-1007
http://www.patton.com

C E R T I F I E D

An ISO-9001

Certified

Company

Содержание 1186

Страница 1: ...Mode Fiber Modem with Fixed G 703 G 704 Interface Part 07M1186 UM Doc 01716U2 001 Rev C Revised 10 25 06 SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com C E R T I F I E D...

Страница 2: ...limited to the following lost profits lost savings and incidental or consequen tial damages arising from the use of or inability to use this product Patton Electronics specifically disclaims all other...

Страница 3: ...3 G 704 terminations Clocking Options Internal Network G 703 G 704 or Receive Recover fiber link Optional AMI or HDB3 G 703 G 704 data coding Six Front Panel LED status indicators Fiber line E1 line L...

Страница 4: ...S2 Setting Description On On Internal Transmit clock generated internally On Off Receive Recover Transmit clock derived from the line Off On Network Transmit clock derived from G 703 G 704 equipment...

Страница 5: ...witches S5 through S8 are reserved for future applications and should be set to OFF 3 1 2 Select RJ 48C or BNC Connectors The Model 1193 is shipped configured for use with a BNC connec tion to the G 7...

Страница 6: ...75 ohm dual coax G 703 G 704 Network inter face If your G 703 G 704 Network terminates via dual coaxial cable 10 use the diagram below to make the proper connections The connec tor pinout and signals...

Страница 7: ...y This section describes power up reading the LED status monitors and using the built in loopback test modes 5 1 POWER UP To apply power to the Model 1186 first be sure that you have read Section 4 3...

Страница 8: ...The local loopback test checks the operation of the local Model 1186 and is performed separately on each unit The following section describes how to perform a local loopback test between the Network a...

Страница 9: ...e RDL test return the front panel switch to the NORMAL position The TM LED should turn off on both local and remote units 5 3 3 V 52 Test Pattern Generator To use the V 52 BER test in conjunction with...

Страница 10: ...errors NS The red NS LED indicates that the sig nal on the fiber side is too weak to be detected ER Flashing red ER LED indicates errors in 511 test pattern TM The yellow TM LED indicates that modem...

Страница 11: ...100 240VAC 5V 5 reg DC 2A Universal Input Adapter 0805EUR European Power Cord CEE 7 A 0805UK United Kingdom Power Cord D 0805US American Power Cord K 0805AUS Australia New Zealand Power Cord C 0805DEN...