PATTON MODEL 1180/35 SPECIFICATIONS

Transmission Format:  

Synchronous

Range:  

1.5 miles at all data rates, 3 miles at 
specified data rates

Data rates:  

2.4, 9.6, 14.4, 19.2, 28.8, 48, 38.4, 56, 
64,128, 144, 192 and 256 Kbps

Interface:

ITU/CCITT V.35 (M/34 female) 

Transmit Mode:  

Single 62.5 or 50 µ core, multi-mode fiber 
cable

Clocking:

Internal, external or received recovered

Handshaking:  

Software (X-ON/X-OFF) or hardware 
(RTS/CTS), both modes available at all 
times

Application:

Point-to-point

Typical Link Budget:

8 dB with a 50 µ cable; 12 dB with a
62.5 µ cable

Responsivity Minimum: 0.12 A/w

LED Indicators:  

TD, RD, RTS, CTS, power, test

Diagnostics:  

Local and remote loopback

Fiber Connector:

ST or SMA

DTE Connector:

M/34 female 

Dimensions:  

4.127"w x 1.52"h x 5.0"l

Power Supply:  

Wall-mount, 7.5VDC

14

SYMPTOM

PROBLEM

SOLUTION

Data passes, but
hardware flow
control doesn't
work

1180/35s work in
async. mode, but
not sync. mode

1. Incorrect DIP switch
setting

1. Incorrect DIP switch
setting

1. Switch 7 must be in
the ON condition for
hardware flow control
signals to pass
between 1180/35s;
both units must be set
the same way

1. Switch 8 (internal/
external clock) must
be set the same way
for both 1180/35s

12

Содержание 1180/35

Страница 1: ...UAL MODEL 1180 35 Single Fiber V 35 Short Range Modem SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1180 35 B Doc 017071UB Revised 4 20 98 An ISO 9001 Certified...

Страница 2: ...designed to provide reasonable protection from such interference in a commercial installation However there is no guarantee that interference will not occur in a particular installation If this unit...

Страница 3: ...ernal external or received recover clock Distances to 1 5 miles over 64 Kbps Distances to 3 miles 64 Kbps and under ST or SMA fiber connectors V 35 DTE interface with female M 34 Local and remote loop...

Страница 4: ...witches S1 1 through S1 4 are set in combination to determine two configuration parameters synchronous data rate and maximum distance Maximum distance is determined by the space between data packets i...

Страница 5: ...ut signal on V 35 pin F 4 0 INSTALLATION The Model 1180 35 is easy to install After configuring the DIP switches simply connect the single fiber cable hook up the V 35 interface and plug the power sup...

Страница 6: ...will appear on the terminal screen continued To perform a local loopback test follow these steps A Activate local loopback by moving the front panel toggle switch DOWN to Local Once local loopback is...

Страница 7: ...h is in the wrong position 3 DIP switches are set improperly 4 Fiber link is connected improperly 5 V 35 connections are faulty or cables are pinned wrong 1 Make sure the AC connection is flush 2 Try...

Страница 8: ...Link Budget 8 dB with a 50 cable 12 dB with a 62 5 cable Responsivity Minimum 0 12 A w LED Indicators TD RD RTS CTS power test Diagnostics Local and remote loopback Fiber Connector ST or SMA DTE Conne...

Страница 9: ...M 34 CONNECTOR V 35 Pin Signal A Frame Ground B SGND Signal Ground C RTS D CTS E DSR F CD H DTR L LL Local Loop M TM Test Mode N RL Remote Loop P TD R RD S TD T RD U XTC V RC W XTC X RC Y TC AA TC Cop...

Отзывы: