background image

S1-5 and S1-6:  Clock Source

Switches S1-1 and S1-2 are set in combination to determine the

source of the transmit clock for the Model 1180/35.

S1-5

S1-6

Setting

Off

Off

Received Recover Clock

On

Off

Internal Clock

Off 

On

External Clock

On

On

Internal Clock

S1-7:  DTE Control of RDL

The setting for switch S1-7 determines whether the V.35 DTE can

activate the RDL test by raising pin L.  If DTE Control of RDL is
enabled, control from the front panel is disabled if there is no DTE
connected.  

NOTE: If DTE control is not avialable, set Switch S1-7 to off.

S1-7

Setting

On

DTE control of RDL enabled

Off

DTE control of RDL disabled

S1-8:  DTE Control of LAL

The setting for switch S1-8 determines whether the V.35 DTE can

activate the LAL test by raising pin N.  If DTE Control of LAL is enabled,
control from the front panel is disabled if there is no DTE connected.  

NOTE: If DTE control is not available, set Switch S1-8 to off.

S1-8

Setting

On

DTE control of LAL enabled

Off

DTE control of LAL disabled

6

Switches S1-1 though S1-4:   Data Rate (Distance)

Switches S1-1 through S1-4 are set in combination to determine

two configuration parameters:  synchronous data rate and maximum
distance.  Maximum distance is determined by the space between data
packets in the communication stream between two Model 1180/35s.
The "2X" setting doubles the space between data packets, when
compared with the normal "1X" setting, and therefore doubles the
maximum distance.   A setting of "2X" facilitates communication
distances up to 3 miles, and is available at certain data rates up to 64
kbps.   A setting of "1X" supports communication at the normal distance
of 1.5 miles.

S1-1

S1-2

S1-3

S1-4

Data Rate (Distance)

On

On

On

Off

2.4 (1X)

Off

On

On

On

9.6 (2X)

On

Off

On

Off

14.4 (1X)

On

Off

On

On

19.2 (2X)

Off

Off

On

Off

28.8 (1X)

Off

Off

On

On

38.4 (2X)

On

On

Off

On

48.0 (2X)

Off

On

Off

Off

56.0 (1X)

Off

Off

Off

On

64.0 (2X)

Off

On

On

Off

72.0 (1X)

Off

Off

Off

Off

128.0 (1X)

On

On

Off

Off

144.0 (1X)

Off

On

Off

On

192.0 (1X)

On

On

On

On

256.0 (1X)

5

S1 SUMMARY TABLE

Position

Function

Factory Default

S1-1

Data Rate (Distance)

Off

S1-2

Data Rate (Distance)

Off 

S1-3

Data Rate (Distance)

Off

S1-4

Data Rate (Distance)

On

S1-5

Clock Source

On

S1-6

Clock Source

On

S1-7

DTE Control of RDL

Off

Disabled

S1-8

DTE Control of LAL

Off

Disabled

}

Internal

}

64 kbps (2x)

Содержание 1180/35

Страница 1: ...UAL MODEL 1180 35 Single Fiber V 35 Short Range Modem SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1180 35 B Doc 017071UB Revised 4 20 98 An ISO 9001 Certified...

Страница 2: ...designed to provide reasonable protection from such interference in a commercial installation However there is no guarantee that interference will not occur in a particular installation If this unit...

Страница 3: ...ernal external or received recover clock Distances to 1 5 miles over 64 Kbps Distances to 3 miles 64 Kbps and under ST or SMA fiber connectors V 35 DTE interface with female M 34 Local and remote loop...

Страница 4: ...witches S1 1 through S1 4 are set in combination to determine two configuration parameters synchronous data rate and maximum distance Maximum distance is determined by the space between data packets i...

Страница 5: ...ut signal on V 35 pin F 4 0 INSTALLATION The Model 1180 35 is easy to install After configuring the DIP switches simply connect the single fiber cable hook up the V 35 interface and plug the power sup...

Страница 6: ...will appear on the terminal screen continued To perform a local loopback test follow these steps A Activate local loopback by moving the front panel toggle switch DOWN to Local Once local loopback is...

Страница 7: ...h is in the wrong position 3 DIP switches are set improperly 4 Fiber link is connected improperly 5 V 35 connections are faulty or cables are pinned wrong 1 Make sure the AC connection is flush 2 Try...

Страница 8: ...Link Budget 8 dB with a 50 cable 12 dB with a 62 5 cable Responsivity Minimum 0 12 A w LED Indicators TD RD RTS CTS power test Diagnostics Local and remote loopback Fiber Connector ST or SMA DTE Conne...

Страница 9: ...M 34 CONNECTOR V 35 Pin Signal A Frame Ground B SGND Signal Ground C RTS D CTS E DSR F CD H DTR L LL Local Loop M TM Test Mode N RL Remote Loop P TD R RD S TD T RD U XTC V RC W XTC X RC Y TC AA TC Cop...