background image

3

4

3.0  CONFIGURATION

The Model 1140A is simple to install and is ruggedly designed for

excellent reliability: just set it and forget it. The following instructions
will help you set up and install the Model 1140A properly. If you have
any questions, don't hesitate to call Patton's Technical Support Hotline
at (301) 975-1007 (9-5 PM, EST).

3.1  CONFIGURATION SWITCHES

The Model 1140A uses a unique set of 16 external mini DIP

switches that allow configuration to an extremely wide range of applica-
tions. These 16 DIP switches are grouped in two eight-switch sets, and
are externally accessible from the underside of the Model 1140A (see
Figure 1). Since all configuration DIP switches are externally accessi-
ble, 

there is no need to open the Model 1140A's case for configu-

ration.

The configuration switches allow you to select data rates, clocking

methods, V.52 & V.54 tests, word lengths, extended signaling rates,
async. or sync. mode. The drawings, text and tables on the following
pages describe all switch locations, positions and functions.

The Model 1140A has two sets of eight switches, yielding 16 total

DIP switches. The two sets will be referred to as S1 and S2. As
Figure 2 shows, the orientation of all DIP switches is the same with
respect to “ON” and “OFF” positions.

3.2  CONFIGURATION SWITCH SET “S1”

The DIP switches on S1 set data rate, clock source, async./sync.

mode and carrier control method. The default settings are summarized
in the table below.

OFF

1 2 3 4 5 6 7 8

OFF

1 2 3 4 5 6 7 8

Figure 1. Model 1140A Configuration Switches External Position

Figure 2. Close-up of DIP switches showing “ON” and “OFF” positions

OFF

ON

S1 SUMMARY TABLE

Position

Function

Factory Default

S1-1

Data Rate

On

S1-2

Data Rate

Off

S1-3

Data Rate

Off

S1-4

Data Rate

On

S1-5

Clock Source

On

S1-6

Clock Source

On

S1-7

Async./Sync.

On

Async.

S1-8

Carrier Control

Off

Constantly On

9,600 bps

Internal

}

}

Figure 3. Summary of DIP switch default settings for set S1

S1

S2

Configuration

Switches

Содержание 1140A

Страница 1: ...MODEL 1140A Miniature Fiber Optic Modem w V 54 Diagnostics SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1140A A Doc 018061UA Revised 10 04 99 An ISO 9001 Certif...

Страница 2: ...ll returns must have a Return Materials Authorization number on the outside of the shipping contain er This number may be obtained from Patton Electronics Technical Service at 301 975 1007 Packages re...

Страница 3: ...s extended signaling rates async or sync mode The drawings text and tables on the following pages describe all switch locations positions and functions The Model 1140A has two sets of eight switches y...

Страница 4: ...hronous operating mode S1 7 Setting On Asynchronous Off Synchronous S1 8 Carrier Control Method The setting for switch S1 8 determines whether the carrier is con stantly on or controlled by RTS This s...

Страница 5: ...6 to the ON position then back to the OFF position S2 8 Setting Off V 54 Enable On V 54 Disable 4 0 INSTALLATION The Model 1140A is easy to install After configuring the DIP switches simply connect th...

Страница 6: ...nt is operating properly and can be used for a test If a fault is indicated call a technician or replace the unit C Perform a BER bit error rate test on each unit If the BER test equipment indicates n...

Страница 7: ...in place and that the Model 1140A s built in 511 generator and detector are working prop erly 5 3 POWER UP Once the Model 1140A is properly installed it should operate transparently as if it were a s...

Страница 8: ...eceive Data From Model 1140A 4 RTS Request to Send To Model 1140A 5 CTS Clear to Send From Model 1140A 6 DSR Data Set Ready From Model 1140A 7 SG Signal Ground 8 DCD Data Carrier Detect From Model 114...