11
3.2
CONFIGURING THE SOFTWARE SWITCHES
The Model 1092A features a menu-driven command system that
allows you to configure the local 1092A. Follow the instructions below
to configure the Model 1092A using the software switches:
1)
Connect the serial RS-232 port of a V100 or similar DTE with
terminal emulation to the EIA/TIA-561l port of the Model
1092A. To construct an RS-232 to EIA-561 patch cable, refer
to the control port pinout diagram in Appendix D.
2)
Power up the terminal and set its RS-232 port as follows:
9600 Baud
8 data bits, 1 stop bit, no parity
Local echo
CR-CR/LF on inbound data
ANSI, VT-100 emulation
3)
Power up the Model 1092A.
4)
After the Model 1092A is powered on, the control port will
send out this message:
Model: 1092A Software version: x.xx
Patton Electronics Copyright
(C)
2000
5)
Press [ESC] on the terminal.
6)
The 1092A will then display the MAIN MENU screen. You
may configure the LOCAL Model 1092A from this screen.
Important!!:
To make a selection from any menu, enter
the option number. To exit any menu without making a
selection, or to return to the previous menu, press the
[ESC] key.
12
3.2.1 Configuring the Local 1092A
To configure the local 1092A, make a selection from the following
MAIN MENU.
MAIN MENU Option 1: Display Active Configuration
Select Option 1 to display the most recent configuration of the local
Model 1092A (See below). The Model 1092A uses the active
configuration for its operation. If you make changes to the
configuration, you must select MAIN MENU Option 8. This will update
the unit to the new active configuration.