Patton electronics 1082/F Скачать руководство пользователя страница 14

 

14

 

SW1-1  Octet Function. 

 

This switch determines whether the modem will 

be set for clear channel mode or Octet timing. The 1082/F can be used 
with either another 1082/F, a 1092A/F or a 1092ARC/C/OO modem from 
Patton. However, when used in Octet timing mode, the 1082/F must be 
used with another 1082/F.

 

SW1-2  Hardware/Software. 

 

When the Model 1082/F is placed into 

SNMP mode (switch SW1-4) the modem must be set to determine what 
will control the modem. When configured for hardware control, the 
1082/F can be viewed through SNMP, but changes can only be made via 
hardware. When configured for software control, changes can be made 
remotely via SNMP software.

 

SW1-3  Front Panel Switch Function. 

 

This switch is used to enable or 

disable the functionality of the front panel switches on the 1082/F.

 

SW1-4  SNMP Control. 

 

This switch is used to allow the 1082 modem to 

be controlled via SNMP when used as the remote CPE modem with a 
1092ARC and a 1001MC management card. 

 

SW1-5 Reserved . 

 

This switch is reserved for internal factory use only 

and should be set to the default position of OFF.

OFF

Octet Aligned

ON

Clear Channel

OFF

Hardware Control (DEFAULT)

ON

Software Control

OFF

Front panel SWs enabled (DEFAULT)

ON

Front panel SWs disabled

OFF

Reserved

ON

SNMP control enabled

Содержание 1082/F

Страница 1: ...UAL MODEL 1082 F iDSL Modem with G 703 Interface SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 Part 07M1082F UM Doc 03317U2 001 Rev C Revised 11 2 06 An ISO 9001 Certified Company C E R T I...

Страница 2: ...ring the Hardware DIP Switches 12 Configuring DIP Switch S1 13 SW1 1 Octet Function 14 SW1 2 Hardware Software 14 SW1 3 Front Panel Switch Function 14 SW1 4 SNMP Control 14 SW1 5 Reserved 14 SW1 6 7 C...

Страница 3: ...IT LEVEL 25 A 12 Load Impedance 25 A 13 Input Signal Level 25 A 14 Jitter Performance 25 A 15 Isoloation 25 A 16 Compliance 25 A 17 LED Status Indicators 25 A 18 Power 25 A 19 Temperature Range 25 A 2...

Страница 4: ...rt 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interfer ence when the equipment is operated in a commercial environment This equipment generates uses...

Страница 5: ...ntainer This number may be obtained from Patton Electronics Technical Service at Tel 301 975 1007 E mail support patton com URL www patton com Note Packages received without an RMA number will not be...

Страница 6: ...ll duplex operation over a single twisted pair 2 wires Able to work in clear channel or Octet timing modes Complies with ITU CCITT G 823 control of jitter Compatible with popular Patton Models 1092A 1...

Страница 7: ...ment is enabled through a 1001MC rack management card located in the Patton Electronics Rack System Figure 1 Typical application HTTP HTML Management The 1001MC maintains HTML pages that can be viewed...

Страница 8: ...modem transmitter so it can directly use the clock The Rx of the second modem recovers the clock and presents a jittery clock RXCLK1 and data RXD1 to the second G 703 s transmitter This transmitter h...

Страница 9: ...G 703 s trans mitter It has to smooth the clock before it uses the clock to transmit The Rx of the second G 703 recovers the timing and clocks the data into a FIFO The Tx of the second modem sends th...

Страница 10: ...ass the smoothed recov ered timing to the modem as XCLK1 with the Rx data as TXD1 and also to the G 703 Tx side Internal Receive Recovered This sets the interface to use the modem s Tx timing recovere...

Страница 11: ...ing frame is embedded in the data Note Octet timing mode is supported only when two 1082 F modems are connected to each other It is not supported when the 1082 F modem is used with the 1092A or 1092AR...

Страница 12: ...nfigurations 3 1 CONFIGURING THE HARDWARE DIP SWITCHES Using a small flat tip screwdriver remove the protective cover located on the underside of the Model 1082 see Figure 4 Figure 4 Removing the cove...

Страница 13: ...h S1 8 Detailed descriptions of each switch follow Table 1 Table 1 DIP Switch Summary Table Position Function Factory Default S1 1 Octet or Clear Channel Mode ON Clear Channel S1 2 SNMP Hardware Soft...

Страница 14: ...nges can only be made via hardware When configured for software control changes can be made remotely via SNMP software SW1 3 Front Panel Switch Function This switch is used to enable or disable the fu...

Страница 15: ...on Use Switch S1 8 to allow Model 1082 F to enter the Remote Digital Loopback diagnostic test when requested to do so by the far end Modem For example when switch S1 8 is set to ON it will enter RDL m...

Страница 16: ...ese units work in pairs Both units at the end of the twisted pair DSL span must be set for the same DTE rate 64 kbps To function properly the Model 1082 needs one twisted pair of metallic wire This tw...

Страница 17: ...pin relationships shown in Figure 8 Figure 8 Model 1082 co directional interface 1 N C 2 N C 3 N C 4 2 Wire TIP 5 2 Wire RING 6 N C 7 N C 8 N C 1 2 3 4 5 6 7 8 Pin Signal Name Direction Function In r...

Страница 18: ...h a male IEC 320 DC Power The 36 60 VDC DC to DC adapter is supplied with the DC version of the Model 1082 The black and red leads plug into a DC source nominal 48VDC and the barrel power connector pl...

Страница 19: ...supply section of the Model 1082 Fuse replacement should only be performed by qualified service personnel Contact Patton Electronics Technical support at 1 301 975 1007 via our web site at www patton...

Страница 20: ...description Table 2 Figure 10 Model 1082 front panel Table 2 LED descriptions DSL Link Active Green Solid green On indicates that the end to end DSL Framer Link is up signifying that the link across t...

Страница 21: ...of a terminal will appear on the terminal screen Figure 11 Local Line loopback To perform an LLB test follow these steps 1 Activate LLB By moving the front panel toggle switch up to Local Once LLB is...

Страница 22: ...est follow these steps 1 Activate RDL by moving the front panel toggle switch down to Remote Note Remote loopback cannot be activated until approximately 45 seconds after the two modems have linked to...

Страница 23: ...52 BER test mode and transmits a 511 test pattern into the loop If any errors are present the local modem s red ER LED will blink continu ously 2 If the above test indicates that no errors are present...

Страница 24: ...n 19 AWG 0 9mm wire 7 2 miles 11 5 km on 22 AWG 0 64mm wire 5 0 miles 8 km on 24 AWG 0 5mm wire 3 4 miles 5 5 km on 26 AWG 0 4mm wire A 6 G 703 DISTANCE 1 mile 1 6 km on a standard G 703 line A 7 A 7...

Страница 25: ...G 823 0 05UI jitter for network extension applications A 15 ISOLOATION 2000 VRMS isolation transformer coupled A 16 COMPLIANCE FCC Class A EN 50081 1 Emissions EN 50082 1 Susceptibility Designed for...

Страница 26: ...0 15 000 feet 0 4 572 meters A 21 HUMIDITY 5 to 95 non condensing A 22 DIMENSIONS 4 125W x 1 625H x 6 0D in 10 5W x 4 1W x 15 2D cm A 23 WEIGHT 2 01 lbs 1 0kg A 24 LINE INTERFACE Transformer coupled 1...

Страница 27: ...sal Input Adapter 0805EUR European Power Cord CEE 7 A 0805UK United Kingdom Power Cord D 0805US American Power Cord K 0805AUS Australia New Zealand Power Cord C 0805DEN Denmark Power Cord E 0805FR Fra...

Страница 28: ..._______________ _________________________________________________________ _________________________________________________________ _________________________________________________________ __________...

Отзывы: