Figure 5.
DIP switches
Figure 5 shows the orientation of the DIP switches in the “ON” and “OFF”
positions.
Configuring DIP Switch S1
DIP switch S1 is where you configure the units for Octet or clear channel
timing, enabling or disabling the front panel switches, SNMP control
enable or disable, Clock mode, and RDL enable or disable.
The following table summarizes default positions of DIP switches S1-1
through S1-8. Detailed descriptions of each switch follow Table 1.
Table 1:
DIP Switch Summary Table
Position
Function
Factory Default
S1-1
Octet or Clear Channel
Mode
ON—Clear Channel
S1-2
SNMP Hardware/Soft-
ware Control
OFF—Hardware control (DEFAULT)
S1-3
Front Panel Switch
Function
OFF—Front Panel Switches Enabled
S1-4
SNMP Control
ON—Enables SNMP control of 1082
S1-5
Reserved
OFF
S1-6
Clock Mode
ON—Internal Clock
S1-7
ON
S1-8
RDL Function
ON—Respond to RDL