background image

Item Numbers

Product Description

0816-21-788

Bathmaster Sonaris2 Bath Lift only

0816-21-796

 Bathmaster Sonaris2 Bath Lift with Turquoise Cover

0816-21-812

Turquoise Seat and Back Cover

0816-21-853

Turning Aid with Cover

0816-21-846

Turning Transfer Aid with Cover

0816-21-861

Premium Hand Controller/Battery

0816-21-903

Fast Battery Charger

0816-21-911

Suction Feet, Pack of 4

Introduction

The Bathmaster Sonaris2 is a patient bathing device intended to assist a bather into and out of the bath. Designed to make the pleasure of 

taking a bath safer and easier, for both user and caregiver, the Bathmaster Sonaris2 is a fully battery-powered, self-contained bath seat, which 

requires no plumbing or electrical installation and is suitable for use in either domestic or institutional situations.
The bath lift folds compactly, and separates into two parts, enabling it to be carried, transported and stored easily.

The Bathmaster Sonaris2 is easily positioned in any standard bath (Note: There are a few extremely narrow or contoured designs of 

bath in which a powered bath seat is not suitable – full details of compatible bath sizes can be found in the Technical Specifications 

section of these instructions). The frame stands on four suction feet that may be rotated to suit the curved floor of the bath. Integral 

“pull- up” tabs on the suction feet, plus a rear release system, enable the Bathmaster Sonaris2 to be easily removed from the bath. 

Replacement components and accessories are available.

In this instruction manual you will find information and instructions on the safe and correct use of your bath lift. Keep all documents in a safe 

place.

Components

The Bathmaster Sonaris2 includes the following components: 
•  White plastic lower seat section with side transfer flaps and four 

suction feet

•  White plastic backrest with motor and cable 

•  Two side flap protectors 
•  Hand controller containing battery pack with LED low-battery 

warning light and audible bleep 

•  Battery recharger with country specific lead and plug 
•  User instructions 
If any of the above components are missing or damaged, do not use 

the Bathmaster Sonaris2 and contact your distributor or Patterson 

Medical. 
Optional accessories are available for those requiring increased 

comfort or functionality.

Do the following

Check the contents to see that all components are included. In the 

rare event that product or components have been damaged, contact 

Patterson Medical immediately.
•  Before using the Bathmaster Sonaris2 for the first time, read 

these instructions and familiarize yourself with the product and 

the lifting techniques. Become familiar with the operation of 

the unit before using it to lower or raise a person.

•  Retain these instructions for future reference and keep them where 

people using the bath lift can have access to them.

•  Ensure the suitability of the unit to lift the individual is assessed. 

Judging the suitability of any patient lifting device is the 

responsibility of the healthcare professional or the caregiver. Some 

circumstances that must be considered include the following: 

size and weight of the individual; his or her upper body strength, 

balance, coordination, cognition and hip flexibility; their potential to 

spasm.

•    Only use the bath lift in baths which comply with the specifications 

outlined in the Technical Specifications section of these instructions.

•   Inspect the unit before each use to be sure it is free from damage 

and excessive wear. Biannual inspections by trained technicians 

are strongly recommended (see Maintaining the Unit).

•  Ensure both the bath surface and suction feet are clean, dry and 

free from soap and bath oil residue before fitting the Bathmaster 

Sonaris2 into the bath.

•  If using bath oils or bath salts, do not use a strong solution. A high 

concentration may impair the slide function of the lifting scissors.

•  While using the bath lift, the user should remain calmly seated. 

Excessive movement should be avoided.

•  Use the Bathmaster Sonaris2 only with accessories, hand 

controllers and rechargers that are supplied by Patterson 

Medical.

•  When the Bathmaster Sonaris2 is being used by a disabled person 

unaided, please ensure that an alarm system or telephone is 

available that could be used in the event of difficulty or emergency.

3

Содержание Sonaris 2

Страница 1: ...User s Manual ...

Страница 2: ...2 C B 2 7 10 8 11 12 9 1 3 4 5 6 ...

Страница 3: ...nstructions If any of the above components are missing or damaged do not use the Bathmaster Sonaris2 and contact your distributor or Patterson Medical Optional accessories are available for those requiring increased comfort or functionality Do the following Check the contents to see that all components are included In the rare event that product or components have been damaged contact Patterson Me...

Страница 4: ... check parts for any damage in transit and that no parts are missing Fitting the suction feet The suction pads must be free from dirt or grease Take care to correctly orientate the straps on the suction pads straps turned outwards Fitting Side Flap Protectors see Fig 12 Screw the front suction pads and rear suction pads see Fig 1 component 6 with the threaded end into the threaded holes on the und...

Страница 5: ...the bather s feet are situated beyond the front legs of the frame When sitting on the seat of the Bathmaster Sonaris2 do not push against the bath such that the front of the bath lift is raised off the floor of the bath as this will make the bath lift unstable Once the Bathmaster Sonaris2 is positioned correctly in the bath it can be used as follows Ensure the unit is tested first before being use...

Страница 6: ...d excess wear The Bathmaster Sonaris2 is built to give long reliable use without need for servicing While being robust the lift should be treated with care and in particular should not be dropped If damage or deterioration is suspected please contact Patterson Medical or the distributor for repair by an approved agent For professionals issuing the Bathmaster Sonaris2 Patterson Medical recommends t...

Страница 7: ...ty for transit damage to the unit Any attempt at repair or maintenance by persons other than Patterson Medical trained or approved personnel will void this warranty Specifications for baths bath lifts see Fig 4 5 Descriptions Dimensions A Bath underside length 31 5 800mm B Bath underside width distance between suction cups 11 24 280 610mm C Bath width at 3 1 8cm height base plate 16 5 420mm D Heig...

Страница 8: ...Notes 8 ...

Страница 9: ...rent Manufactured during date Meets applicable European standards Raise the seat Double insulated Lower the seat 375 lbs Warning read manual Recycle battery contains Lithium ion Dispose of battery and motor correctly contains electronic components Recycle battery contains Lithium ion Total Product Weight Type B electrical insulation Emergency stop C 40 Max min battery operating temperature Li ion ...

Отзывы: