33
TROUBLESHOOTING
WARNING
To prevent serious injury from fire: Follow the kit procedures in a well-
ventilated area away from ignition sources. If the engine is hot from use,
shut the engine off and wait for it to cool before proceeding.
NOTICE
The warranty may be void if necessary adjustments are not made for
high altitude use.
HIGH ALTITUDE REPLACEMENT KIT FOR EPAIII ENGINES
3000ft to 6000ft or 6000ft to 8000ft of elevation
• At high altitude, the standard carburetor air-fuel mixture will be too rich.
Performance will decrease and fuel consumption will increase. A very rich
mixture will also foul the spark plug and cause hard starting. Operation at an
altitude that differs from that at which this engine was certified, for extended
periods of time, may increase emissions.
• The fuel system on this Engine or Equipment may be influenced by operation
at higher altitudes. Proper operation can be ensured by installing an altitude
kit when required. See the table below to determine when an altitude kit is
required. Operating this generator without the proper altitude kit installed may
increase the engine’s emissions and decrease fuel economy and performance.
Kits may be obtained from any Dealer, and should be installed by a qualified
individual.
* Engine, Generator Set, Pressure Washer, Walk-Behind Lawnmower,
Compressor, Pump, Tiller etc.
** Elevation above sea level.
* This high altitude jet is to be used at elevations above 3000 feet.
* At elevations above 8000 feet, the engine may experience decreased
performance, even with the high altitude kit.
If a carburetor is replaced, the proper high altitude kit jet will need to be
installed into the replacement carburetor.
Equipment model*
Fuel
Altitude Range** Kit Part Number
Gasoline
0 – 3000 ft
Not Required
3000 – 6000 ft
Altitude kit 1#
6000 – 8000 ft
Altitude kit 2#
spark.
· Spark plug dirty with carbon or wet … Remove carbon or wipe spark
plug dry.
· Faulty ignition system … consult our company authorized dealer.
9.2 Generator won’t produce power
· Safety device (DC protector) to “OFF”…. Press the DC protector to
“ON”.
· The AC pilot light (Green) goes off …. Stop the engine, then restart.
Содержание GI-3500P
Страница 1: ...USER MANUAL GI 3500P GI 3600 INVERTER GENERATOR...
Страница 35: ...35 11 WIRING DIAGRAM WIRING DIAGRAM...
Страница 40: ...If you need assistance with the assembly or operation of your Generator please call 1 866 850 6662...
Страница 46: ...35 11 SCH MA DE C BLAGE SCH MA DE C BLAGE...
Страница 80: ...MANUEL UTILISATEUR GI 3500P GI 3600 G N RATEUR D ONDULEUR...