background image

TO AVOID SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE: 

For your safety, do not store or use gasoline or other flammable vapors or liquids in 

the vicinity of this or any other appliances. Keep the area free and clear of 

combustible. (See ANSI Z83. 14B, 1991).   

Improper installation, adjustment, alteration, service or maintenance of this 

equipment can cause property damage, personal injury, or death and voids warranty. 

Read the installation operating and maintenance instructions thoroughly before 

installing, or operating this equipment.   

Instructions must be posted in a prominent location. All safety precautions must be 

taken in the event the user smells gas. If you smell gas, immediately shut off the 

main gas valve, extinguish all heat and flames, and call 911. Safety information can 

be obtained from your 

local gas supplier.   

IMPORTANT SAFEGUARDS & SAFETY INSTRUCTIONS 

When using gas cooking equipment, basic safety precautions should always be 

followed, including the following:   

The Griddle outside surfaces may become HOT after use. Use caution when touching the unit. 

· 

Never directly touch the burners or cooking grates while the Griddle is on.   

· 

Always turn off the unit when not in use, servicing or adjusting any parts or attachments, and before 

cleaning.   

· 

Never leave the Griddle on overnight. 

· 

Do not operate any equipment with a damaged or leaking gas line, ignitor or valves or if the unit is dropped 

or damaged in any manner.    Call for service.   

· 

The use of attachments not recommended or sold by the manufacturer may cause fire, injury or even death. 

· 

Do not use outdoors.   

· 

Do not use this equipment for any use other than the use intended by the manufacturer.   

· 

Never use the Griddle as a heating source   

· 

The Griddle does not contain any user-serviceable parts. Dealers or recommended qualified technicians 

should carry out repairs. Do not remove any components or service 

panels on this product.   

· 

Never bypass, alter, modify or attach any unauthorized parts to this equipment. Doing so may create 

hazards and will void warranty   

· 

Vender takes every care to ensure that all products are safe. Steel cutting procedures used to manufacture 

these items result in sharp edges. These sharp edges are removed to the best of our ability; however, we 

insist the operator take care when in contact with this piece of equipment.   

· 

Always keep hands, hair and clothing away from heating source.   

· 

Allow the Griddle to cool down after use and before dismantling for cleaning; the unit will be too hot to handle 

immediately after use. 

Содержание PT-G24-M

Страница 1: ......

Страница 2: ...tly followed when using this equipment Please retain this manual for future reference Instructions must be posted in a prominent location All safety precautions must be taken in the event the user sme...

Страница 3: ...3 Index ATTENTION OWNERS AND OPERATORS 4 UNPACKING INSTALLATION 5 6 WARNINGS SAFEGUARDS FOR OPERATION 7 OPERATING INSTRUCTIONS 8 9 CLEANING INSTRUCTIONS 10 TROUBLESHOOTING 11 LIMITED WARRANTY 16...

Страница 4: ...r unauthorized personnel come in contact with this equipment Please remember that vender cannot anticipate every circumstance or environment in which its equipment will be operated It is the responsib...

Страница 5: ...toff valve to be supplied by user must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of psi 3 45 kPa These models are designe...

Страница 6: ...with legs mounted lift if necessary to move unit 7 The supplied gas pressure regulator is factory set at 4 Natural gas W C or 10 for L P 8 THESE UNITS ARE SUITABLE FOR INSTALLATION ON NON COMBUSTIBLE...

Страница 7: ...rn off the unit when not in use servicing or adjusting any parts or attachments and before cleaning Never leave the Griddle on overnight Do not operate any equipment with a damaged or leaking gas line...

Страница 8: ...s each burner has its own individual pilot The pilot can be reached through the holes in the front of the unit 5 Adjust the pilot valve make sure the pilot flame at 1 2 inch height 6 Turn each burner...

Страница 9: ...t independent of changing draft conditions NOTE It may be necessary to adjust the balance of gas volume and air supply to each burner This must be done by an authorized service technician Seasoning th...

Страница 10: ...cloth Daily Controls Unit should be turned off when not in use Daily It is recommended that the unit be disconnected from the gas supply by closing the main gas valve Use a clean cloth to wipe any dow...

Страница 11: ...king area Main gas line leak Turn off main gas valve DO NOT LIGHT FLAME ignite anything or turn switch on anything electrical Call fire department if needed and call for service Cooking surface is hea...

Страница 12: ...from Natural Gas to Propane L P on all models The conversion should be done before connecting the unit to the gas supply Units are shipped from the factory equipped for use on natural gas Parts necess...

Страница 13: ...13 6 Continue with installation L P Position of insert Regulator is now converted to L P...

Страница 14: ...14...

Страница 15: ...maintenance We all recognize however that replacement parts and occasional professional service may be necessary to extend the useful life of this unit When service is needed contact an Authorized Se...

Страница 16: ...n subject to misuse neglect abuse accident alteration negligence damage during transit delivery or installation fire flood riot or act of God Equipment that has the model number or serial number remov...

Отзывы: