33
TROUBLESHOOTING
Problem
Possible cause
Solution
Screw driver does not work
Empty battery
Recharge the battery pack
Battery overheated above 45°C
Let the battery cool down
Vibrations are too strong
Screws or parts of the machine
are loose
Check and tighten all screws
Motor overheated
Overload due to excessive
pressure to work
Allow the motor to cool down by
running the power tool idle at
maximum speed for 1 minute
Charger does not work
Mains socket is not live
Check mains socket and/or
circuit breaker/RCD
Power cable fault
Check whether power cable is
disconnected or damaged
Battery is not recharging
Temperature of battery is
outside of safe range 0-45°C
Let the battery reach normal
temperature before charging
TECHNICAL DATA
Cordless screwdriver PATRIOT AS036-5
No load speed
230/min
Max torque
5 Nm
Chuck clamping
1/4“ (hex)
Max. screw diameter
5 mm
Weight
0,4 kg
Battery
Li-ion
Rated voltage battery capacity
3,6 V
1,5 Ah
Battery charger for Li-ion PATRIOT
Rated voltage
100–240 V, 50-60 Hz
Charging voltage and current
5,5 V
0,5 A
Noise and vibration
The declared noise and vibration emission values have been measured in accordance with a standard
test method provided by EN 60745 and may be used for comparing one power tool with another. The
declared vibration can also be used in a preliminary assessment of exposure.
Warning!
Vibration value during actual use of the power tool can differ from the declared value
depending on the way the power tool is used. The vibration level may increase above the level stated.
When assessing vibration exposure to determine safety measures under Regulation 2002/44/EC to
protect persons regularly using power tools in employment, exposure to vibration should consider, the
actual conditions of use and the way the power tool is used, including taking into account all parts of the
operating cycle such as the times when the power tool is switched off and when it is running idle in
addition to the start time.
Sound pressure level L
pA
= 74 dB(A)
Uncertainty K = 3 dB (A)
Sound power level L
wA
= 85 dB(A)
Uncertainty K = 3 dB (A)
Vibration level a
h
= 1,26 m/s
2
Uncertainty K = 1,5 m/s
2
Содержание AS036-5
Страница 2: ...2...