PATON
Standard
DC MMA
-16 -
Recommended length of power welding cables during welding:
Maximum
current
Cable length, m
(one way)
Cross-section area,
sq. mm
Cable brand
not more than 160А
2 ... 7 m
16 mm
2
KG 1х16
not more than 200А
3 ... 9 m
25 mm
2
KG 1х25
not more than 250А
5 ... 11 m
35 mm
2
KG 1х35
not more than 270А
5 ... 11 m
35 mm
2
KG 1х35
up to
350А
6 ... 14 m
35 mm
2
KG 1х35
TECHNICAL PARAMETERS
PARAMETERS
Standard-350-400V
Rated supply voltage 50Hz, V
3x380
3х400
Supply voltage variation limits, V
±15%
Rated current consumption from the mains phase, A
17,7
Rated welding current, A
350
Maximum operating current, A
450
Load duration (LD)
70% /at
350А
100% /at 290A
Limits of regulation of welding current, A
50
–
350
“Hot
-
Start”
function
Automatic
“Arc Force”
function
Automatic
“Anti
-
Stick”
function
Automatic
No-load voltage, V
up to 80
Arc striking voltage, V
110
Rated power consumption, kVA
11,7
Maximum power consumption, kVA
15,2
Efficiency, %
90
Cooling
Forced
Operating temperature range
–25 … +45ºС
Overall dimensions (length, width, height), mm:
390 х 145 х 335
Weight without accessories, kg
9,8
Protection rating
IP33
Содержание STANDART-350-400V
Страница 1: ......
Страница 3: ...3 PATON Standard DC MMA UKRAINE DIN 9 10 85 8...
Страница 4: ...PATON Standard DC MMA 4 1 2 3 4 B ABICOR BINZEL 3 ABICOR BINZEL 3...
Страница 7: ...7 PATON Standard DC MMA Standard 350 400V 3...
Страница 8: ...PATON Standard DC MMA 8 RUSSIAN DIN 9 10 85 8...
Страница 9: ...9 PATON Standard DC MMA 1 2 3 4 B ABICOR BINZEL 3 ABICOR BINZEL 3...
Страница 12: ...PATON Standard DC MMA 12 PATON Standard 350 400V 3...