background image

 

   

          

-15 -       

PATON

 StandardMIG

 MMA/TIG/MIG/MAG

 

drop  transfer  into  the  weld  pool  and,  consequently,  on  the  stability  of  the  weld 
forming  and  of  the  welding  process.  In  other  words,  this  process  substitutes 
movements  of  welder’s  hand  to  some  extent,  which  is  especially  important  in 
hard‐to‐reach places. The correct setting determines weld shape and quality of the 
weld  forming,  thus  reducing  risk  of  porosity  and  grain  structure  of  the  weld  and 
consequently increasing weld strength. 

In  order  to  implement  this  function,  three  parameters  must  be  set  in  the 

machine:  pulsing  power  [Po.P],  pulsing  frequency  [Fr.P]  and  mark‐to‐space  ratio 
(or duty ratio) [dut]. By default, pulsing power [Po.P], which is the key parameter, 
is set to “OFF” position, i.e. disabled, while pulsing frequency [Fr.P] and duty ratio 
[dut] are set to the most common values of 50Hz and 50% respectively. In order to 
enable this function, it is enough to set pulsing power [Po.P] to a value above zero. 
This parameter is set in percent of the current set value of base arc welding. 

Example: welding with a Ф3mm electrode, set the base value of arc current is 

60 A, and pulsing power [Po.P] = 40%, while pulsing frequency [Fr.P] = 5.0Hz and 
duty ratio [dut] = 50% by default. 

Result:  current  will  pulse  in  the  range  from  36A  to  84A  with  a  frequency  of 

5Hz; pulses will be of the same shape in terms of both magnitude and time. If duty 
ratio  parameter  [dut]  is  changed  to  a  value  other  than  50%,  pulses  become 
asymmetric—between the current pulse time and the current “pause” time: 

by default 

“duty ratio” [dut] = 50% 

“duty ratio” [dut] = 20% 

“duty ratio” [dut] = 70% 

 

 

The  machine  calculates  pulsing  in  such  a  way  that,  at  a  constant  set 

differential of pulses, average level of welding current is maintained at the level of 
set base welding current value of 60A (i.e. equal to the set value), in order to keep 
the resulting average heat input into the weld at a constant level of 60A, but the 
stability of the welding process and the mixing of the weld pool will change. This is 
necessary  in  the  situation,  when  a  user  has  reduced  base  current  and  provided 
maintenance of stable welding process using pulses—thus, decrease of heat input 
can also be clearly determined by comparison with initial base current. 

These  parameters  are  set  differently  in  different  situations  in  accordance 

with welding operator’s requirements. See Clause 6.1 for sequence of changing the 
value of any function in the current welding mode. 

 

t, s 

t, s 

t, s 

Содержание StandardMIG -200

Страница 1: ......

Страница 2: ...PATON StandardMIG MMA TIG MIG MAG 2...

Страница 3: ...tion 18 5 Semiautomatic metal inert active gas welding MIG MAG 19 5 1 Welding cycle MIG MAG 2T 21 5 1 1 Function of button on a 2T torch 21 5 2 Welding cycle MIG MAG 4T 22 5 2 1 Function of button on...

Страница 4: ...0 4 mm up to 160 1 0 mm at most 2 0 75 2 5 95 4 0 155 6 0 230 StandardMIG 200 3 mm 120 at most 0 8 mm at most 1 5 75 2 0 105 2 5 130 4 0 205 6 0 310 4 mm 160 at most up to 1 0 mm 2 0 75 2 5 95 4 0 155...

Страница 5: ...hich allows user changing torches at his her own discretion This StandardMIG model by PATON is equipped with a unit for minute undervoltage protection as well as against minute overvoltage Due to the...

Страница 6: ...ck function in MMA mode automatic automatic automatic automatic Open circuit voltage reduction unit on off on off on off on off MMA open circuit voltage V 12 75 12 75 12 75 12 75 Arc striking voltage...

Страница 7: ...7 PATON StandardMIG MMA TIG MIG MAG...

Страница 8: ...or wait mode during tungsten arc inert gas welding and semiautomatic welding as well as source overheating in any mode c blinks green and yellow while welding in any mode d permanent red light in case...

Страница 9: ...E The welding machine is designed solely for manual metal arc welding with a stick electrode tungsten arc inert gas welding as well as semiautomatic metal inert active gas welding Other use of the mac...

Страница 10: ...achine is connected to mains voltage exceeding 270V Such a situation can occur with a very large phase voltage imbalance in a standard mains or using non standard connection In addition manufacturer s...

Страница 11: ...the modes switch over end around use buttons 1 to set the main parameter which is welding current if necessary additional functions of welding process can be adjusted see a changeover sequence in Clau...

Страница 12: ...t Start value in such a case The result is achieved by the following means In the moment of arc striking welding current increases by the default value of 40 for a short time Example welding with a 3...

Страница 13: ...Arc Force magnitude and a trigger level to unnecessarily high value because at high limit values especially during welding with thin electrodes less than 3 2mm in diameter affects actuation of Anti St...

Страница 14: ...d welding when very long arc is undesirable For this purpose the machine provides the possibility to set the Short Arc function Sh A to ON position By default it is set to OFF position See Clause 6 1...

Страница 15: ...ing power Po P 40 while pulsing frequency Fr P 5 0Hz and duty ratio dut 50 by default Result current will pulse in the range from 36A to 84A with a frequency of 5Hz pulses will be of the same shape in...

Страница 16: ...ottle valve check the tightness connect the mains plug to the supply mains set power switch 14 on the rear panel to position I set the TIG welding mode by pressing the button 6 the modes switch over e...

Страница 17: ...en electrodes and ingress of its inclusions into the weld which is very adverse effect Attention This requires cleaning the work piece at the point of the arc striking This function is implemented by...

Страница 18: ...the filler wire into the weld pool The correct setting determines weld shape and quality of the weld forming thus reducing risk of porosity and grain structure of the weld and consequently increasing...

Страница 19: ...with welding operator s requirements See Clause 6 1 for sequence of changing the value of any function in the current welding mode 5 SEMIAUTOMATIC METAL INERT ACTIVE GAS WELDING MIG MAG Attention In...

Страница 20: ...le if there is no experience then initially set to the middle position this is about 3 using buttons 12 set the required wire feed speed use button 8 to pull the wire through the entire channel and ad...

Страница 21: ...eneral recommendations on semiautomatic welding Remember that these parameters are different for each specific application 5 1 WELDING CYCLE MIG MAG 2T See Clause 6 1 for sequence of changing the valu...

Страница 22: ...n Clause 5 1 After the button is released the function of arc current fade out and wire feeding speed during the t dn time is tested and then the source turns off Next the function of the post purging...

Страница 23: ...ter testing the function of pre purging the welding zone with gas during the t Pr time the process of arc striking starts this is similar to that in the 2T button mode This mode is provided by the PAT...

Страница 24: ...or and the right indicator of the wire feeding machine 5 6 FUNCTION OF POST PURGING WITH SHIELDING GAS This function consists in the subsequent purging of the welding zone with a shielding gas after t...

Страница 25: ...ty ratio dut 50 duty ratio dut 20 duty ratio dut 70 The machine calculates pulsing in such a way that at a constant set differential of pulses average level of arc voltage is maintained at the level o...

Страница 26: ...cussed in Clause 6 2 Buttons 1 on the front panel of the source is responsible for changing the current value on the digital display on the left Button 12 on the front panel of the wire feeding machin...

Страница 27: ...ront panel 6 3 RESET OF ALL FUNCTIONS SETTINGS FOR THE CURRENT WELDING MODE There can be situations when the user becomes confused with the machine settings In order to reset them to standard factory...

Страница 28: ...ding mode 0 2 main parameter CURRENT 100A by default a 8 160 increment 1 for StandardMIG 160 b 10 200 increment 1 for StandardMIG 200 c 12 250 increment 1 for StandardMIG 250 1 t uP current fade in ti...

Страница 29: ...ng with shielding gas time 0 5s by default 0 1 25 0s increment 0 1s 3 t P0 post purging with shielding gas time 1 5s by default a 0 1 25 0s increment 0 1s 4 t uP wire feeding speed fade in time 0 1s b...

Страница 30: ...heavy use it is recommended to purge it with dry compressed air once per six months Attention If the machine is purged from a very short distance electronic components may be damaged if the machine is...

Страница 31: ...LIVERY SET 1 Welding arc supply source with a mains cable 1 pcs 2 Rollers 0 6 0 8 and 1 0 1 2 1 pcs 3 PATON brand corrugated box 1 pcs 4 3m semiautomatic torch 1 pcs 5 3m welding cable with electrode...

Страница 32: ...go relevant qualifying examination have knowledge about welding carefully follow these instructions Malfunctions that can reduce safety must be eliminated immediately USER S RESPONSIBILITIES The user...

Страница 33: ...use such appliances shall consult with a doctor before approaching the operating welding area welding cable must be robust intact and insulated Loose connections and damaged cables must be immediately...

Страница 34: ...PATON StandardMIG MMA TIG MIG MAG 34 Schematic electrical diagram of the PATON StandardMIG 160 200 250 DC MMA TIG MIG MAG...

Страница 35: ...16 ACCEPTANCE CERTIFICATE Arc inverter rectifier PATON StandardMIG 160 200 250 Serial number ________________S has been approved for operation Sale date _________________ _____ 20____ Place of seal _...

Страница 36: ...____________ signature Symptoms of non operability __________________________________________ ____________________________________________________________________ Cause _______________________________...

Страница 37: ..._____________ signature Symptoms of non operability __________________________________________ ____________________________________________________________________ Cause ______________________________...

Отзывы: