9. DELIVERY SET 

1.

 

Welding arc supply source with a mains cable 

 1 pce. 

2.

 

Shoulder carrying strap 

 

 

 1 pce. 

3.

 

PATON brand corrugated/plastic* box  

 1 pce. 

4.

 

3 m welding cable with an electrode holder 

 1 pce. 

5.

 

3 m welding cable with earth terminal   

 1 pce. 

6.

 

Operating manual 

 

 

 

 1 pce. 

*For MINI-C, ECO-160-C, ECO-200-C, ECO-250-C only

 

 

10. TROUBLESHOOTING 

Fault

 

Cause

 

Correction

 

No arc current

 

The mains switch is on, 
but the status indicator 
is not lit. 

Mains cable break 

Check the mains cable. 

Supply mains voltage is 
lower than 155 V 

Disconnect  the  machine 
and connect it to the mains 
with  proper supply voltage 

Supply  mains  voltage 
exceeds 

the 

permissible  value  of 
260 V 

Disconnect  the  machine 
and connect it to the mains 
with  proper supply voltage 

Internal source supply 
unit has failed 

Contact the service facility 

No arc current

 

The mains switch is on, 
the 

source 

status 

indicator lights green 

Welding cables are 
disconnected 

Check plug connection 

Earth is not connected or 
connected poorly 

Establish  reliable  connection 
of  the  earth  cable  with  the 
work  piece 

No arc current

 

The mains switch is on, 
the 

source 

status 

indicator lights yellow 

Temperature sensor has 
been actuated 

Wait  until  the  machine  cools 
down; then it will switch on again 
automatically 

Insufficient cooling air 
supply 

Provide sufficient air inflow 

Temperature sensor is 
faulty 

Contact the service facility 

Bad  striking  during 
welding  with  a  stick 
electrode, 

the  source 

status indicator flashes 
green for short periods 

Supply mains voltage at 
the  start  of  loading  is 
near 

the 

minimum 

permissible value of 165 
V. 

If  it  is  impossible  to  increase 

cross‐section

  of  feeding  mains 

cables,  try  reducing  the  set 
current value, until it will allow for 
striking  the  arc.  Then  use  an 
electrode  corresponding  to  the 
current value. 

Continuation of table on page 14.

 

 

Содержание MINI

Страница 1: ......

Страница 2: ...PATON ECO DC MMA 2...

Страница 3: ...3 PATON ECO DC MMA 1 5 2 9 2 1 9 2 2 9 2 3 9 2 4 10 3 MMA 10 3 1 Hot Start 10 3 2 Arc Force 11 3 3 Anti Stick 12 4 12 5 13 6 13 7 13 8 13 9 14 10 15 11 16 12 19 13 20...

Страница 4: ...DC MMA 4 25 2 80 1 0 120 1 5 180 2 0 240 2 5 300 4 0 480 6 0 720 3 120 1 5 120 2 0 160 2 5 200 4 0 320 6 0 480 4 160 2 0 120 2 5 150 4 0 240 6 0 360 5 200 2 5 120 4 0 190 6 0 290 5 250 2 5 100 4 0 15...

Страница 5: ...5 PATON ECO DC MMA 1 PATON MINI ECO 160 ECO 200 ECO 250 MMA MINI 150A 160 200 250 1 6 5 250 40 PATON 1 170 260 170 3 2 3 3 4 5 6 7...

Страница 6: ...50 180 190 240 300 40 150 100 94 40 160 100 101A 40 200 100 126A 40 250 100 158 20 150 20 160 25 200 32 250 Hot Start Arc Force Anti Stick 80 80 80 80 110 110 110 110 4 0 4 4 5 5 7 0 5 0 5 5 6 9 8 8 9...

Страница 7: ...7 PATON ECO DC MMA MINI ECO 160 1 4 8 1 8 2 5 10 1 10 3 8 16 1 16 ECO 200 1 4 10 1 10 2 6 5 16 1 16 3 10 25 1 25 ECO 250 1 5 16 1 16 2 8 25 1 25 3 11 35 1 35...

Страница 8: ...PATON ECO DC MMA 8 1 1 2 3 4 5 B...

Страница 9: ...9 PATON ECO DC MMA 2 11 2 1 2 2 5 5 5 3 4 4 2 3 220 23 18 260...

Страница 10: ...PATON ECO DC MMA 10 2 4 3 MMA B 3 I 2 I 3 1 HOT START 33 3 3 90...

Страница 11: ...11 PATON ECO DC MMA 90 33 120 3 2 ARC FORCE 30 4 3 HOT START...

Страница 12: ...PATON ECO DC MMA 12 4 ARC FORCE 3 3 ANTI STICK 0 6 0 8 4 5...

Страница 13: ...13 PATON ECO DC MMA 5 2 80 2 6 3 120 4 1 4 160 5 5 5 200 6 9 5 250 8 8 170 260 6 4 15150 69 5 5 0 7 8...

Страница 14: ...20 220 220 220 170 260 170 260 170 260 170 260 90 90 90 90 20 150 20 160 25 200 32 250 5 45 5 100 150 94 160 101 200 126 250 158 5 0 5 5 6 9 8 8 20 4 25 5 20 4 26 20 4 26 5 20 4 27 0 9 1 1 2 3 1 3 3 1...

Страница 15: ...15 PATON ECO DC MMA 10 155 165 16...

Страница 16: ...PATON ECO DC MMA 16 15 11...

Страница 17: ...17 PATON ECO DC MMA...

Страница 18: ...PATON ECO DC MMA 18...

Страница 19: ...19 PATON ECO DC MMA 12 PATON MINI R 4 DC 0430 0440 0432 0442 0000 0002 0421 0431...

Страница 20: ...PATON ECO DC MMA 20 13 MINI 3 ECO 160 5 ECO 200 ECO 250 PATON...

Страница 21: ...21 PATON ECO DC MMA...

Страница 22: ...PATON ECO DC MMA 22 1 24 2 28 2 1 28 2 2 28 2 3 28 2 4 29 3 MMA 29 3 1 Hot Start 29 3 2 Arc Force 30 3 3 Anti Stick 31 4 31 5 32 6 32 7 32 8 32 9 33 10 34 11 35 12 38 13 39...

Страница 23: ...ECO DC MMA 25 2 80 1 0 120 1 5 180 2 0 240 2 5 300 4 0 480 6 0 720 3 120 1 5 120 2 0 160 2 5 200 4 0 320 6 0 480 4 160 2 0 120 2 5 150 4 0 240 6 0 360 5 200 2 5 120 4 0 190 6 0 290 5 250 2 5 100 4 0 1...

Страница 24: ...PATON ECO DC MMA 24 1 PATON MINI ECO 160 ECO 200 ECO 250 MMA Eco 150A 160 200 250 1 6 5 250 40 1 170 260 170 3 2 3 3 4 5 6 7...

Страница 25: ...0 180 190 240 300 40 150 100 94 40 160 100 101A 40 200 100 126A 40 250 100 158 20 150 20 160 25 200 32 250 Hot Start Arc Force Anti Stick 80 80 80 80 110 110 110 110 4 0 4 4 5 5 7 0 5 0 5 5 6 9 8 8 90...

Страница 26: ...PATON ECO DC MMA 26 MINI ECO 160 1 4 8 1 8 2 5 10 1 10 3 8 16 1 16 ECO 200 1 4 10 1 10 2 6 5 16 1 16 3 10 25 1 25 ECO 250 1 5 16 1 16 2 8 25 1 25 3 11 35 1 35...

Страница 27: ...27 PATON ECO DC MMA 1 1 2 3 4 5 B...

Страница 28: ...PATON ECO DC MMA 28 2 11 2 1 2 2 5 5 5 3 4 4 2 3 220 23 18 260...

Страница 29: ...29 PATON ECO DC MMA 2 4 3 MMA B 3 I 2 3 I 3 1 HOT START...

Страница 30: ...PATON ECO DC MMA 30 33 3 3 90 90 33 120 3 2 ARC FORCE 30 4 3 HOT START...

Страница 31: ...31 PATON ECO DC MMA 4 ARC FORCE 3 3 ANTI STICK 0 6 0 8 4 5 130...

Страница 32: ...PATON ECO DC MMA 32 5 2 80 2 6 3 120 4 1 4 160 5 5 5 200 6 9 5 250 8 8 170 260 6 4 15150 69 5 5 0 7 8...

Страница 33: ...220 220 220 220 170 260 170 260 170 260 170 260 90 90 90 90 20 150 20 160 25 200 32 250 5 45 5 100 150 94 160 101 200 126 250 158 5 0 5 5 6 9 8 8 20 4 25 5 20 4 26 20 4 26 5 20 4 27 0 9 7 1 8 3 1 9 3...

Страница 34: ...PATON ECO DC MMA 34 10 155 165 35...

Страница 35: ...35 PATON ECO DC MMA 34 11...

Страница 36: ...PATON ECO DC MMA 36...

Страница 37: ...37 PATON ECO DC MMA...

Страница 38: ...PATON ECO DC MMA 38 12 PATON ECO MINI 160 200 250 DC 0430 0440 0432 0442 0000 0002 0421 0431...

Страница 39: ...39 PATON ECO DC MMA 13 MINI 3 ECO 160 5 ECO 200 ECO 250 PATON...

Страница 40: ...PATON ECO DC MMA 40...

Страница 41: ...ns plug connection 47 3 Welding with stick electrodes mma 47 3 1 Hot Start function 48 3 2 Arc Force function 48 3 3 Anti Stick function 49 4 Attendance and technical maintenance 49 5 Generator operat...

Страница 42: ...A at most 1 5 120 2 0 160 2 5 200 4 0 320 6 0 480 4mm 160 A at most 2 0 120 2 5 150 4 0 240 6 0 360 5mm low melting 200 A at most 2 5 120 4 0 190 6 0 290 5 mm high melting 250 A at most 2 5 100 4 0 15...

Страница 43: ...smaller That s why weight and overall dimensions of this machine is several times smaller than those of regular equipment with identical output parameters Main advantages 1 In addition to voltage surg...

Страница 44: ...g voltage V 110 110 110 110 Rated power consumption kW 4 0 4 4 5 5 7 0 Maximum power consumption kW 5 0 5 5 6 9 8 8 Efficiency factor 90 90 90 90 Cooling forced Operating temperature range 25 45 25 45...

Страница 45: ...45 PATON ECO DC MMA Fig 1 Control elements and indication...

Страница 46: ...not responsible for damage cause by undue use of the machine Intended use of the machine implies adherence to instructions of this operating manual 2 2 INSTALLATION REQUIREMENTS The welding machine i...

Страница 47: ...tor cross sections of power supply cables and supply line fuses must be selected on the basis of technical specifications of the machine 2 4 MAINS PLUG CONNECTION ATTENTION Mains plug shall correspond...

Страница 48: ...the following means In the moment of arc striking arc current increases by 33 of the set arc current value for a short time Fig 3 Example welding with an electrode of 3 mm in diameter Arc current val...

Страница 49: ...AINTENANCE ATTENTION Before opening the machine switch it off and disconnect the mains plug Wait until internal circuits of the machine de energize about 5 minutes and only then proceed with other act...

Страница 50: ...tive substances 7 TRANSPORTATION A packaged source can be transported by any means of transportation which provide its integrity complying with all transportation rules established for this type of tr...

Страница 51: ...service facility No arc current The mains switch is on the source status indicatorlightsgreen Welding cables are disconnected Checkplugconnection Earth is not connected or connectedpoorly Establish re...

Страница 52: ...f the machine or property of the enterprise derangement of efficient working process All persons dealing with start up operation attendance and maintenance of the machine must undergo relevant qualify...

Страница 53: ...53 PATON ECO DC MMA 12 WIRING DIAGRAM Schematic electrical diagram of the Source MINI ECO 160 ECO 200 ECO 250 DC 0430 0440 0432 0442 0000 0002 0421 0431...

Страница 54: ...of heavy objects on the machine falling out of buttons and connectors damaged due to corrosion broken down due to the impact of moisture on its power and electronic elements broken down due to conduc...

Страница 55: ...of the machine manufacture identified by serial number as the start of warranty period if the user lost the data sheet if the seller did not fill in the data sheet when selling the machine or filled i...

Отзывы: