July 2021
53
PWVIA RM P12 Ethernet Switches - Manual
FACTORY DEFAULT
In the event of a loss of communication with the device (e.g. Management VLAN accidentally set to a value outside the VLAN
range), it is possible to reset the switch to factory settings.
To factory default a switch, turn the encoder knob to the switch main menu, which is the default menu showing the switch’s
name and IP address. Click in the encoder to access the main menu.
POE
LINK/ACT
PORT 1
PORT 2
PORT 3
PORT 4
PORT 5
PORT 6
PORT 7
PORT 8
PORT 9
PORT 10
TM
Rotary Encoder
Turn to Highlight
Push to Select
Base Configuration
Network Setup
Device Info/Status
Advanced Settings
Admin/Security
<Back>
Scroll the encoder knob until “
Admin/Security”
is highlighted, and click in the knob. Under the Admin/Security menu, scroll
down to “
Factory Default
”, and click in the knob.
Admin/Security
Factory Default
Manage Restore Point
Reset Security
Reboot
<Back>
This will show the Factory Default menu. Here you have several options.
Factory Default
Keep Net Setup & Restore Pt.
Keep Restore Point
Wipe All Configuration
<Back>