background image

POWER IN

Blue

. Steady glow indicates power supply OK; 

off indicates no power.

PROCESSOR

Green

. Steady glow indicates processor is OK; 

off  when  POWER  IN  is  lit  indicates  processor 

failure.

DMX INPUT

Amber

.  Steady  glow  indicates  port  latched 

to  active  DMX  source;  off  indicates  no  signal 

present.

CCI MODE

Red

. Steady glow indicates contact closure input 

mode is active.

FUNCTION

Amber

.  Indicates  the  function  associated  with 

the numeric display.

Model 1006 24-Channel  

Analog to DMX

Manual

1006-200-REV1

04/25/19

TM

The 1006 Analog to DMX interface provides the ability to 

convert analog 0-10VDC signals to DMX512 protocol. The 

analog inputs may also be used as dry contact inputs, either 

triggering a DMX channel to full, or to recall up to 24 presets. 
The DMX input may be merged with the analog input signal or 

with the preset recall. The DIN form factor makes installation 

in your own enclosures or cabinets fast and easy.

The module is RDM discoverable and configurable.

The 1006 features terminal strips that can be removed from the 

card to facilitate easy wiring installation or replacement. Make the 

following connections, 

WITH THE POWER TURNED OFF.

POWER

The module will run on a range from 9 to 30 VDC at a maximum 

of 5 Watts. Observe the correct polarity when connecting the V+ 

and V-. A second set of terminals are provided on the connector to 

daisy-chain power to other eDIN modules. The EARTH GROUND 

terminal must be connected to the enclosure’s chassis or electrical 

ground terminal to ensure EMC compliance.

DMX512

DMX connections consist of a shield and data pair. Connect the 

DATA+ and DATA- wires to D1+ and D1- respectively for each of 

DMX IN, DMX OUT and DMX THRU (if applicable). Observe the 

same polarity convention throughout the system. Connect the cable 

shield to the SHLD COM terminal.
DMX  OUT  is  the  processed  output  of  the  interface.  DMX  IN  is 

optional; DMX input will be merged with the analog inputs or used 

as a source of levels when recording presets.
DMX THRU may be daisy-chained to the DMX IN of other eDIN  

modules.

OVERVIEW

CONNECTIONS

STATUS INDICATORS

ANALOG / CONTACT CLOSURE INPUTS

The 1006 supports 24 discrete inputs that can be configured as 

either analog or contact closure inputs. The COM (common) terminal 

must be used as a signal reference, regardless of input configuration.
Analog inputs must be 0 to +10 VDC with respect to COM. Contact 

inputs are simply maintained or momentary dry contact closures 

between COM and the individual input.

V+

V-

V+

V-

NC

NC

D1+

COM SHLD

D1-

NC

NC

D1+

COM SHLD

D1-

ON

OFF

DMX INPUT

ISO 5V PWR

POWER IN

9-30VDC

5 W MAX

ENTER

eDIN 24 CHANNEL

ANALOG     DMX

ADDRESS

MODE

UTIL

TEST

EARTH

GND

CCI MODE

PROCESSOR

DC POWER IN

D1+

SHLD

COM

DMX OUT D2+

D2-

D1-

4

3

2

1

5

9

8

7

6

10

14

13

12

11

15

19

18

17

16

20

24

23

22

21

COM

24 ANALOG / CONTACT CLOSURE INPUTS

(10VDC MAX ANALOG MODE;

NO VOLTAGE ALLOWED IN

CONTACT CLOSURE MODE

END OF LINE

TERMINATION SWITCH

DMX OUTPUT

DMX IN FROM 

CONTROL SYSTEM

DMX THRU TO

OTHER eDIN MODULES

STATUS LEDs

MENU FUNCTION

LEDs

POWER IN:

9-30VDC, 5W SUPPLY REQUIRED

USE #1001-100-24-DIN POWER SUPPLY

OR EQUAL.

CONNECT EARTH GROUND TO PROTECT

DMX INPUT FROM RF INTERFERENCE

CARRIED ON CABLE SHIELD.

LED NUMERIC

DISPLAY

PROGRAM

PUSHBUTTONS

Отзывы: