Operator's
Manual
DS 350 / 1361 RT 875 CC
© PAT Revision E // SB // 09/03/02
190137_E
32
7 SERVICE AND MAINTENANCE
Daily maintenance of the load moment indicator consists of inspecting:
The electrical wiring connecting the various parts of the system.
If electrical wiring is damaged, it shall be replaced immediately.
If the insulation is worn on the length sensor cable or cable guides are damaged, these
parts shall be replaced.
Check the anti two-block limit switches for freedom of movement.
The cable reel shall be under tension to operate properly.
Check the pressure transducers at the hoist cylinder(s) and the connecting hoses for oil
leakage.
Other than correcting the problems identified in the ErrorCodes Table and replacing faulty
mechanical parts and cables, no other repairs shall be performed by non expert personnel.