5 INSTALLATION
5 - 31
GB
These procedures may only be carried out by professional staff with sound experience in mechanical/
electrical installation procedures.
Check that the pack contains all the device's components. The Extractor Fan must be installed in such a
way that its rotation axis is vertical and it is on the top of the compartment for ventilation. The Extractor
Fan's outlet must be in direct contact with the external environment and must be unimpeded by fixed or
movable obstructions for a radius of at least 60 cm. Make a suitable hole in the roof of the vehicle and
follow the mechanical assembly instructions for the fan unit as shown.
EXTERNAL PROTECTION
GRID
INTERNAL
PROTECTION
GRID
ROOF
MIN 34 mm - MAX 105 mm
MIN 600 mm
A
XIS OF
ROTA
TION
SCREWS
Firm rigid fixing to the vehicle's structure must be ensured.
All the components shown must be installed correctly.
important
After installation, check that there are no water leaks into the vehicle, that there is no dirt in the fan-
unit and that the fan turns absolutely freely.