2

WARNING

Water and moisture:

  This device should not be used near water ( as per example, near a bath-

tub, washbasin, kitchen sink, laundry tub, wet basement or swimming pool ).  Care should be 
taken such that objects do not have the opportunity to fall, and that liquid is never spilled onto 
or into the device enclosure through openings.

Power Sources:

  This device must  be connected to a mains power source in strict accordance 

with the supplied  product owners manual.  Please verify that the AC mains voltage specifi ed 
in the product manual matches those requirements indicated on the unit and the AC volt-
age provided to your location by the power company. The product MUST be connected to a 
MAINS socket outlet with a protective earthing connection.

Power Cords:

  Pass Labs provides a power supply cord that meets all legislated requirements 

for the market in which the product was originally sold.  If you choose to substitute an af-
ter-market product we urge you to choose one that is fully safety rated by the necessary local 
authority.

Power supply cords should be routed so that they are not likely to be walked on, abraded, or 
pinched by items placed on or against them, paying particular attention to cords where they 
enter plugs or exit from a device.  Never under any circumstance insert a cut or damaged 
power cord into a mains power socket. Cables should never be connected / disconnected 
with equipment powered up.  Failure to heed this warning may damage or destroy equip-
ment.

Ventilation:

  Power-amplifi ers run warm, but you should be able to place your hands on them 

without discomfort.  You must allow for this heat in installation, by providing for free air circula-
tion around the product.  Leave a minimum of 6” of space around the amplifi er. The ventila-
tion should not be impeded by covering the ventilation openings with items, such as newspa-
pers, table-cloths, curtains, etc.

Other Warnings:

No naked fl ame sources, such as lighted candles, should be placed on the apparatus; This 
amplifi er is suitable for tropical climates under 2000m and ambient temperatures of 40 degrees 
C or less.

Servicing:

  To reduce the risk of fi re, electrical shock or other injuries, the user should not at-

tempt to service the device beyond that which is described in the operating instructions.  All 
other servicing must be referred to qualifi ed service personnel.

For Units With Externally Accessible Fuse Receptacle:

 Unplug the device from all sources of 

power before changing  or inspecting any fuse.  Replace fuse with one of same physical size, 
type and rating as that specifi ed by the manufacturer for that product.

Country Specifi c Warnings:

China: For use at altitude 2000m or lower.
Norway: Apparatet må tilkoples jordet stikkontakt.
Sweden: Apparaten skall anslutas till jordat uttag.
Finland: Laite on liitettävä suojakoskettimilla varustettuun pistorasiaan.
Denmark: Apparatets stikprop skal tilsluttes en stikkontakt med jord, som giver forbindelse til 
stikproppens jord.

Trademarks: 

“Pass”, “

pass

”, “Pass Labs”, “Pass Laboratories”, Supersymmetery”, 

“Aleph”, and “Zen” and are all registered trademarks of Pass Laboratories, Inc., and 
all rights thereto are protected by law.

Содержание XP-27

Страница 1: ...1 pass XP 27 Owner s Manual ...

Страница 2: ...stroy equip ment Ventilation Power amplifiers run warm but you should be able to place your hands on them without discomfort You must allow for this heat in installation by providing for free air circula tion around the product Leave a minimum of 6 of space around the amplifier The ventila tion should not be impeded by covering the ventilation openings with items such as newspa pers table cloths cur...

Страница 3: ... of music in a real physical space Like some great musicians we get requests You spoke and we listened so that you can listen better Now the XP 27 a product designed at the intersections of excellence adaptability and convenience The twin chassis XP 27 eclipses the already exceptional performance of the well reviewed and well received XP 15 XP 25 XP 17 delivering enhanced RIAA performance at a fra...

Страница 4: ... in the transformers iron core For the time the promise of the best moving coil cartridges went un realized The XP 27 s high gain and exceptionally low noise figure allow for ample output and detail from cartridges providing as little as 40 uV micro volts of signal at the phono input The adjustable gain options of the XP 27 make this unit immune from overload with any high output cartridge of which...

Страница 5: ... all instances will be 50 60 Hz Please verify that that voltage indicated on the product is consistent with the nominal voltage supplied at your location All XP 27 products are protected by a voltage specific type fuse 5mm x 20mm slow blow For 100 Volts ac and 120 Volts ac the fuse will be 1 amp for 220 Volts ac and 240 Volts ac the fuse will be amp In all instances the fuse will have a slow blow t...

Страница 6: ...th a series loading of 47k ohms and 100 pf of parallel capacitance Like gain these settings too are selectable from the front panel of the XP25 Presuming 47k ohm in the case of moving magnet greatest benefit comes from exploring the pallet of available capacitive loading choices Infrequently moving magnet cartridges will perform best at other than 47k ohm but that would be an exception Moving Iron ...

Страница 7: ...ifically in selecting a cartridge load we will be listening for a compromise loading which sounds best across the whole audio spectrum and specifically not that loading which optimizes one cut on one LP The front panel controls of the XP 27 load each channel of the phono cartridge independently through closely matched devices to preserve the best possible spatial elements of recordings The XP 27 is ...

Страница 8: ...ay be worth considering and optimizing this parameter once resistive loading is optimal Again I would like to stress that you are listening for a musical balance in the selections that you play Some loading selections will offer better bass but suffer from poor high end resolution some will have spectacular high end definition but have a flat sound stage You are seeking an optimal condition with cor...

Страница 9: ...ever subtly Experience correlating what sounds good to knowledge of component design yields some general guidelines as to what will sound good and what will not sound good in real life 1 Simplicity and a minimum number of components is a key element and is well reflected in the quality of better tube designs The fewer pieces in series with the signal path the better This is often true even if addin...

Страница 10: ...ics will differ slightly due to the different metallurgy of the fuse elements between commercial grade and audio grade fuses We can t guarantee that your audiophile grade fuse won t blow at a different in rush current threshold than your stock commercial fuse Use of other than approved fuses may invalidate your product warranty and result in product damage XP 27 Specs Gain options 56 66 76dB RIAA ...

Страница 11: ... factory or shipping product to the factory for repair Non North American product must be returned to the country of origin for warranty service Foreign distributors are only required to offer warranty service on Pass Laboratories product that they have imported verifiable by serial number Please note Conditions of warranty service and customer rights for product purchased outside the United States...

Страница 12: ...12 pass Pass Laboratories Inc 13395 New Airport Rd Suite G Auburn CA 95602 530 878 5350 passlabs com ...