Pass Laboratories INT-25 Скачать руководство пользователя страница 2

2

WARNING

Water and moisture:

  This device should not be used near water ( as per example, near a bath-

tub, washbasin, kitchen sink, laundry tub, wet basement or swimming pool ).  Care should be 
taken such that objects do not have the opportunity to fall, and that liquid is never spilled onto 
or into the device enclosure through openings.

Power Sources:

  This device must  be connected to a mains power source in strict accordance 

with the supplied  product owners manual.  Please verify that the AC mains voltage specifi ed 
in the product manual matches those requirements indicated on the unit and the AC volt-
age provided to your location by the power company. The product MUST be connected to a 
MAINS socket outlet with a protective earthing connection.

Power Cords:

  Pass Labs provides a power supply cord that meets all legislated requirements 

for the market in which the product was originally sold.  If you choose to substitute an af-
ter-market product we urge you to choose one that is fully safety rated by the necessary local 
authority.

Power supply cords should be routed so that they are not likely to be walked on, abraded, or 
pinched by items placed on or against them, paying particular attention to cords where they 
enter plugs or exit from a device.  Never under any circumstance insert a cut or damaged 
power cord into a mains power socket. Cables should never be connected / disconnected 
with equipment powered up.  Failure to heed this warning may damage or destroy equip-
ment.

Ventilation:

  Power-amplifi ers run warm, but you should be able to place your hands on them 

without discomfort.  You must allow for this heat in installation, by providing for free air circula-
tion around the product.  Leave a minimum of 6” of space around the amplifi er. The ventila-
tion should not be impeded by covering the ventilation openings with items, such as newspa-
pers, table-cloths, curtains, etc.

Other Warnings:

No naked fl ame sources, such as lighted candles, should be placed on the apparatus; This 
amplifi er is suitable for tropical climates under 2000m and ambient temperatures of 40 degrees 
C or less.

Servicing:

  To reduce the risk of fi re, electrical shock or other injuries, the user should not at-

tempt to service the device beyond that which is described in the operating instructions.  All 
other servicing must be referred to qualifi ed service personnel.

For Units With Externally Accessible Fuse Receptacle:

 Unplug the device from all sources of 

power before changing  or inspecting any fuse.  Replace fuse with one of same physical size, 
type and rating as that specifi ed by the manufacturer for that product.

Country Specifi c Warnings:

China: For use at altitude 2000m or lower.
Norway: Apparatet må tilkoples jordet stikkontakt.
Sweden: Apparaten skall anslutas till jordat uttag.
Finland: Laite on liitettävä suojakoskettimilla varustettuun pistorasiaan.
Denmark: Apparatets stikprop skal tilsluttes en stikkontakt med jord, som giver forbindelse til 
stikproppens jord.

Trademarks: 

“Pass”, “

pass

”, “Pass Labs”, “Pass Laboratories”, Supersymmetery”, 

“Aleph”, and “Zen” and are all registered trademarks of Pass Laboratories, Inc., and 
all rights thereto are protected by law.

Содержание INT-25

Страница 1: ...1 pass INT 25 Owner s Manual ...

Страница 2: ...stroy equip ment Ventilation Power amplifiers run warm but you should be able to place your hands on them without discomfort You must allow for this heat in installation by providing for free air circula tion around the product Leave a minimum of 6 of space around the amplifier The ventila tion should not be impeded by covering the ventilation openings with items such as newspa pers table cloths cur...

Страница 3: ...ult is faster lower distortion lower noise higher damping and larger Class A operating envelope into low impedance loudspeakers all in a simple 3 stage circuit with total of three pair of push pull gain transistors In their ideal state matched push pull FETs give perfect square law cancellation of distortion an effect somewhat spoiled by degenerative Source resistance used to constrain the persona...

Страница 4: ... periods The amplifier is designed to perform well with the included power cord Should you select an after market detachable power cord please confine your selection to those rated by local authorities to carry a minimum of 13A at 250V At idle the INT 25 will consume 275W from the AC mains The required voltage and correct fuse value will be indicated on the rear of the amplifier Both 100 Vac and 120 ...

Страница 5: ...our dealer or the factory if you have problems The Furutech binding posts deserve special note in keeping with the requirements of Class 2 circuits in North America they are fully insulated Speaker cables connected as intended will have no exposed conductive metal The Furutech posts accept banana spade bare wire or pins with a diameter of 4 5mm or less Bare wire pins and spades socket into the bin...

Страница 6: ...e button or reach the limits of the volume control Balance is not used with the INT 25 This is used on other Pass preamps and has no effect on this product Tape is not used with the INT 25 This is used on other Pass preamps and has no effect on this product Pass Thru is not used with the INT 25 This is used on other Pass preamps and has no effect on this product Display The default setting for the...

Страница 7: ...7 ...

Страница 8: ...utting them in wrong could cause damage Replacing the fuse The fuse should only be replace with the same type and size as indicated on the rear Audio Specialty FUSE NOTE The Overload and Time Delay characteristics will differ slightly due to the different metallurgy of the fuse elements between commercial grade and audio grade fuses We can t guarantee that your audiophile grade fuse won t blow at ...

Страница 9: ...factory or shipping product to the factory for repair Non North American product must be returned to the country of origin for warranty service Foreign distributors are only required to offer warranty service on Pass Laboratories product that they have imported verifiable by serial number Please note Conditions of warranty service and customer rights for product purchased outside the United States ...

Страница 10: ...10 pass Pass Laboratories Inc 13395 New Airport Rd Suite G Auburn CA 95602 530 878 5350 passlabs com ...