Now switch on the transmitter (please refer to transmitter operating instructions).
The RF indicator will light up when the correct channel is selected, indicating that
the radio signal transmitted has been received.
Use RF test button to test if there is interference around. If there is interference
around, the RF signal level LED will light up. The receiver is indicating to switch to
another frequency.
When an audio signal into the microphone, the audio indicator will flash to show
the strength of the audio level.
OPERATING INSTRUCTIONS
Before switching on the receiver, make sure that the units antenna system is
attached and placed at 45 degree angles opposite of each other (Polarization
Diversity) and that the unit is positioned in an unobstructed location.
3
8
The MW165U has a module design. To change or replace a capsule, Open the grill to pull out
and plug in the capsule as shown in the following figure.
CHANGING OF CAPSULE
The MW165U has a sensitivity switch, For close singing or normal speech put the switch to
the N (normal) position. For tripod-mount speech, put the switch to the H (high) position.
SENS
H
N
Low Sensitivity
High Sensitivity
SENS
H
N
OPERATING INSTRUCTIONS
SENSITIVITY SWITCH
MW165U
PROFESSIONAL AUDIO & SOUND
®
FRONT AND REAR PANEL CONTROL
1.
Power switch
2.
Power on indicator
3.
RF signal indicator
4.
Diversity indicator
5.
AF signal indicator
6.
Channel selector
7.
RF test button
8.
Volume control
9.
Antenna B socket
10.
XLR ( balanced ) audio output
11.
Unbalanced audio output
12.
Squelch ( SQ ) control.
13.
D C IN jack
14.
Antenna A socket
ON
RF SIGNAL LEVEL
AF SIGNAL LEVEL
DIVERSITY
RF-TEST
CHANNEL
VOLUME
MIN
MAX
A
B
1
3
5
7
9
15
13
11
PLL TRUE DIVERSITY RECEIVER
RDU216
POWER
1
2
3
4
5
6
7
8
9
11
12
13
14
10
RDU216
PROFESSIONAL AUDIO & SOUND
®
Before operation, please check and make sure that transmitter & receiver are of
matching channels.
To switch on the microphone, put the switch to "ON" position. The red LED indicator will
light briefly indicating that battery is fresh. When the RED LED light is steady, it indicates
that battery is weak, thus a replacement is necessary.
For best results, an alkaline battery is recommended. Please remove the battery if the
transmitter is not to be used for a longer period.
When necessary, the MW165U microphone capsule can be replaced by pulling out and
plugging in the new one.
For close singing or speaking, put the sensitivity switch to N (Normal) and for mic stand
applications or when the speaker stands away
, put the sensitivity switch to
H (High). Be careful to put back the sensitivity switch to N for close singing as H (High)
sensitivity for close vocal applications may cause distortion.
When holding the handheld microphone, please do not hold the antenna end of the unit
for it will severely affect the efficiency of the transmission range.
at a distance