PAGE 16
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
ADDRESSABLE VOX SYSTEM
VOX - VOICE ACTIVATED MUTING
- The Amplifier is
equipped with a noiseless, fast acting Logic VOX Switching
System. When any of the INPUTS are activated and a
Signal is present on a given INPUT and the VOX 1 is
Switched-ON (using internal Jumpers) then the MUTE 1
BUSS is ACTIVE. If any of the INPUTS have the MUTE 1
Switched-ON (by Internal Jumpers) then the INPUT (or
INPUTS) will be MUTED according to the Jumpers Setting.
Once the SIGNAL-ON on the ACTIVE INPUT is terminated
the normal functions are automatically restored on all muted
inputs.
ACCESS TO VOX AND MUTE JUMPERS
REFER TO JUMPERS AND SWITCHES INTERNAL
ACCESS.
CAUTION: PRIOR TO PERFORMING THE ABOVE OPER-
ATION BE SURE TO FOLLOW THE SAFETY NOTES
REFERRING TO THE REMOVAL OF THE AMPLIFIER
COVER.
Fig. 16 - Rear Panel VOX 1 Sensitivity Control
and MUTE Time Delay Control
VOX - VOICE ACTIVATED MUTING
VOX SENSITIVITY CONTROLS
23
24
VOX
SENS
MUTE
DELAY
3-30 SEC
DMA2015 Vox Sens 01
V
OX SENSITIVITY ADJUSTMENT
1) Turn all Front Panel Input Level Controls to 0.
2) Turn VOX Sensitivity Control counterclockwise until it
stops.
3) Connect a Signal Source (Microphone, Telephone or
Music) to the respective Input Terminals (For connection
details refer to the appropriate section in this Manual).
4) While talking from a Paging Source (Microphone or
Telephone) or Playing Music rotate the INPUT LEVEL CON-
TROLS (Front Panel) until the desired output level is
achieved.
5) While talking from a Paging Source (Microphone or
Telephone) or Playing Music, turn the Sensitivity Control
(VOX 1) slowly clockwise until the Muting is activated.
VOX JUMPERS DEFAULT SETTING TABLE
S110
INPUT 3
-
VOX1 - OFF
OFF
S108
INPUT 4
-
VOX1 - OFF
OFF
S114
INPUT 1
-
VOX1 - OFF
V1
S203
TEL IN
-
VOX1 - OFF
V1
JUMPER
JUMPER
FUNCTION
FACTORY
FACTORY
ID NO.
REFERENCE
DESCRIPTION
SETTING
SETTING
MAIN PCB JUMPERS
VOX SENSITIVITY CONTROL
VOX 1 SENSITIVITY CONTROL
The VOX 1 Sensitivity Control sets the sensitivity level at
which point the VOX 1 is engaged during INPUT ACTIVA-
TION. The VOX Sensitivity Control is located on the
Amplifier Rear Panel.
VOX 1 SENSITIVITY CONTROL = Reference 24
VOX SENSITIVITY ADJUSTMENT
INSTALLATION AND WIRING
PROFESSIONAL AUDIO & SOUND
®
DIGITAL MUSIC AMPLIFIERS
DMA2015/2030/2060/2120