W e a t h e r / A n e m o m e t e r   S e n s o r

  P S - 2 1 7 4

2

 Figure 1: Mounting options and air flow direction

Interface and Software 
Configuration (Optional)

The interface or software automatically prepares itself for data 
recording when you connect the sensor. Follow the steps below to 
change the default settings.

GLX Configuration (Standalone Mode)

To Add Measurements to the Digits Screen

In the Digits screen, press G, H, or I to display more measure-
ments.

To Change the Displayed Measurement

In any display screen, press c twice to open the data source menu, 
from which you can select a measurement for display.

To Change Measurement Units

1.

In any display screen, press c to light up the active fields.

2.

Use the arrow keys to highlight the measurement unit.

3.

Press c to open the units menu, from which you can select a 
different unit.

To Change the Sampling Rate

1.

Open the Sensors screen by pressing h + I.

2.

Press c to open the Sample Rate Unit menu. For rates faster 
than once per second, select 

samples/s

. For slower rates, 

Select 

seconds

minutes

, or 

hours

.

3.

Press d to highlight 

Sample Rate

.

4.

Press + or - to change the rate or time between samples.

DataStudio Configuration

To Create a New Data Display

1.

Double-click the Graph, Digits, or other display icon in the 
Summary bar. A list of data sources appears.

2.

Select the measurement that you want to display and click 

OK

.

To Change Measurement Units

1.

Click 

Setup

 to open the Experiment Setup window.

2.

Under the first or second Measurements tab, click the unit of 
measure that you want to change. A menu opens.

3.

Click the desired unit.

To change the sampling rate

1.

Click 

Setup

 to open the Experiment Setup window.

2.

Click the units next to the sample rate setting. A menu opens. 
For rates faster than once per second, select 

Hz

. For slower 

rates, Select 

seconds

minutes

, or 

hours

.

3.

Click the arrow buttons next to the 

Sample Rate

 setting to 

change the rate or time between samples.

Data Collection

GLX (standalone mode)

To Display Data without Recording

Open the Digits or Meters screen. The GLX displays live data.

To Record Data

1.

Press s. The GLX starts recording data.

2.

Press s again to stop recording.

3.

Press s again to start recording in a new data run.

DataStudio

To Display Data without Recording

1.

Open the Experiment menu and select 

Monitor

. DataStudio 

displays live data.

Mounting Hole

Air Flow

Air Flow