background image

C h e m i s t r y   M u l t i M e a s u r e   S e n s o r

T e c h n i c a l  S u p p o r t

12

012-09523B

Technical Support

For assistance with any PASCO product, contact PASCO at:

Limited Warranty

For a description of the product warranty, see the PASCO catalog.

Copyright

The PASCO scientific 012-09523B 

Chemistry MultiMeasure Sensor Instruction Manual

 is copyrighted with all rights reserved. Permission is 

granted to non-profit educational institutions for reproduction of any part of this manual, providing the reproductions are used only in their labo-
ratories and classrooms, and are not sold for profit. Reproduction under any other circumstances, without the written consent of PASCO scien-
tific, is prohibited.

Trademarks

PASCO, PASCO scientific, PASCO Capstone, MultiMeasure Sensors, PASPORT, SPARK Science Learning System, SPARKvue, and Xplorer 
GLX are trademarks or registered trademarks of PASCO scientific, in the United States and/or in other countries. All other brands, products, or 
service names are or may be trademarks or service marks of, and are used to identify, products or services of, their respective owners. For 
more information visit www.pasco.com/legal. Teflon is a registered trademark of DuPont.

Product End of Life Disposal Instructions:

This electronic product is subject to disposal and recycling regulations that vary by country and region. It is your responsibility to recycle your 
electronic equipment per your local environmental laws and regulations to ensure that it will be recycled in a manner that protects human health 
and the environment. To find out where you can drop off your waste equipment for recycling, please contact your local waste recycle/disposal 
service, or the place where you purchased the product.

The European Union WEEE (Waste Electronic and Electrical Equipment) symbol (to the right) and on the product or its 
packaging indicates that this product must not be disposed of in a standard waste container.

Address: PASCO scientific

10101 Foothills Blvd.
Roseville, CA 95747-7100

Phone:

916-462-8384 (worldwide)
877-373-0300 (U.S.)

Web:

www.pasco.com

Email:

[email protected]

Содержание PASPort PS-2170

Страница 1: ...yurethane Tubing 60 cm 0 125 inch ID 6 Quick release Connectors qty 4 Hose and Coupling Kit 7 Tubing Connectors qty 4 8 Syringe 60 cc 9 Alligator Clip with Insulator qty 2 each Polyurethane Tubing blu...

Страница 2: ...RP port BNC port Align the grooves of the BNC connector on the probe with the pins on the BNC port Push the connector onto the port and turn the connector clockwise until it locks in place If you plan...

Страница 3: ...easurement for that display Using SPARKvue HD Connect a PASPORT compatible interface to the computer and start the SPARKvue HD software Refer to the documentation that came with your PASPORT interface...

Страница 4: ...measurement can be displayed in units of C F or K You can use the included stainless steel probe or a different probe such as the Fast response Temperature Probe PS 2135 or Skin Surface Temperature Pr...

Страница 5: ...Electrode Maintenance and Storage Cleaning If the pH electrode becomes contaminated use one of these methods to clean and restore it After any of these procedures rinse the electrode with deionized w...

Страница 6: ...tors to connect the tubing to larger diameter tubing or to a rubber stopper with a hole Note Do not allow liquid to enter the pressure port Voltage Use the voltage component of the multi sensor to mea...

Страница 7: ...Model No PS 2170 Specifications 7 012 09523B Voltage Range 10 V to 10 V Accuracy 0 1 V Resolution 0 04 mV Voltage Protection up to 240 V Input Resistance 2 M...

Страница 8: ...ept Move to the third step 3 The third step in the panel is to choose the type of calibration Two Standards 2 point is the default Click Next 4 The fourth step in the panel is to calibrate the first p...

Страница 9: ...he Graph display screen to open the Experiment Tools menu In the Experiment Tools menu touch Calibrate Sensor The screen will show Calibrate Sensor Select Measure ment The Sensor Chemistry Measurement...

Страница 10: ...be in distilled water 5 For Calibration Point 2 touch the down arrow to scroll down to the bottom of the screen Place the probe s sensor into the second known standard such as the pH 7 buffer solution...

Страница 11: ...s pH Probe into the first known standard pH 4 buf fer solution Wait a few moments and then press F3 H to Read Pt 1 5 Use the down arrow to scroll down to the second calibration point Highlight Pt 2 mV...

Страница 12: ...products or service names are or may be trademarks or service marks of and are used to identify products or services of their respective owners For more information visit www pasco com legal Teflon i...

Отзывы: