RP-330 Technical Manual
50
ESC c 4
n
[Name]
Select paper sensor(s) to stop printing
[Format]
ASCII
ESC
c
4
n
Hex
1B
63
34
n
Decimal 27
99
52
n
[Range]
0≤
n
≤255
[Description]
Selects the paper sensor(s) used to stop printing when a paper-end is detected,
using
n
as
follows.
Bit
Off / On
Hex
Decimal
Function
0
Off
00
0
Paper roll near end sensor disabled.
On
01
1
Paper roll near end sensor enabled
1
Off
00
0
Paper roll near end sensor disabled
On
02
2
Paper roll near end sensor enabled
2 – 7
-
-
-
Undefined
[Details]
·When a paper sensor is enabled with this command, printing is stopped
only
when the corresponding paper is selected for printing.
·When a paper-end is detected by the paper roll sensor, the printer goes off-line
after printing
stops.
·When either bit 0 or 1 is on, the printer selects the paper roll near-end sensor
for the paper
sensor to stop printing.
[Default]
n = 0
ESC c 5 n
[Name]
Enable / disable panel buttons
[Format]
ASCII
ESC
c
5
n
Hex
1B
63
35
n
Decimal 27
99
53
n
[Range]
0≤
n
≤255
[Description]
Enables or disables the panel buttons.
·When the LSB of n is 0, the panel buttons are enabled.
·When the LSB of n is 1, the panel buttons are disabled.
[Details]
·Only the lowest bit of n is valid.
·When the panel buttons are disabled, none of them are usable when the
printer cover is closed.
·In this printer, the panel buttons are the FEED button.
·In the macro ready mode, the FEED button are enabled regardless of the settings of this
command; however, the paper cannot be fed by using these buttons.
[Default]
n
= 0
Содержание RP-330
Страница 1: ...RP 330 Thermal Receipt printer Technical manual...
Страница 16: ...RP 330 Technical Manual 16 2 1 9 Interface Connector...