P
AGE
69
Performance Specifications
Measurement Error Limit
• Type J,K,T,E,N, & C thermocouples and RTD
±
0.25% of reading plus 1 degree at 25 degree C
• Type R,S, & B thermocouple
±
0.25% of span at 25C
• mVDC, mADC and VDC
±
0.25% of scaled span plus
1 least significant digit at 25 degrees C
Ambient Temp. Error
0.01% of span per degree C deviation from 25
degrees C
Scan Rate
1 scan per second
3 scans per second with EA Option
Display Resolution
0 to 3 decimal places (depending upon input type
selected)
Auto Reset Windup Inhibit Auto reset is disabled when the process is outside of
the proportional band
Cold Junction
Self compensation for ambient temperature. All
Compensation
calibration values are stored in memory
Noise Rejection
Normal mode, 85dB minimum at 60 Hz or greater.
Common mode, 90dB minimum
±
8VDC maximum
peak for RTD input, 115 VAC maximum for other inputs
Line Voltage
115/230 VAC
±
10% 50/60 Hz
Power Consumption
15VA maximum
Operating Temperature
0 to 55 degrees C
32 to 131 degrees F
Storage Temperature
-40 to 65 degrees C
-40 to 149 degrees F
Humidity
0 to 90% RH, noncondensing
Dimensions
1/4 DIN front panel (96mm X 96mm) 5.8 inches deep
Weight
3 pounds maximum
Vibration
0.5 to 100 Hz at 0.5g
Agency Approvals
UL and CSA
Warranty
3 years, see inside back page for more details