background image

  

 

Parry

-British Built for Purpose 

IN270-2

 

12 

  Technical Instructions   

 

High Rate Per Burner (All figures are NET) 

 

 
 

High Rate Total Unit (All figures are NET) 

 

 

Model  

 

Injector Code 

PGG6 

Propane G31 @ 37mbar 14.8” W.G. 

INJECT082 

PGG6 

Nat Gas G2

0 @ 20mbar 8” W.G. 

INJECT130 

 

 
 
 
 
 
 
 

Gas 

Operating Pressure 

Total Heat Input 

NATURAL   G20 

20mb/8”      W.G. 

2.400 KW = 8190Btu/h 

PROPANE  G31 

37mb/14.8” W.G. 

2.726 KW = 9300 Btu/h 

Gas Rate 

M³/HR 

FT³/HR 

LB/HR 

KG/HR 

NATURAL   G20 

0.254 

8.970 

 

 

PROPANE  G31 

0.112 

3.938 

0.433 

0.196 

AIR FLOW RATE 
FOR COMBUSTION 
20m3/hr 

3.18 

112.3  

 

 

Gas 

Operating Pressure 

Total Heat Input 

NATURAL   G20 

20mb/8”      W.G. 

4.810 KW = 16412 Btu/h 

PROPANE  G31 

37mb/14.8” W.G. 

5.451 KW = 18599 Btu/h 

Gas Rate 

M³/HR 

FT³/HR 

LB/HR 

KG/HR 

NATURAL   G20 

0.509 

17.975 

 

 

PROPANE  G31 

0.223 

7.875 

0.865  

0.392 

AIR FLOW RATE 
FOR COMBUSTION 
20m3/hr 

6.36 

224.6 

 

 

Содержание PGG6

Страница 1: ...Instruction Manual PGG6 PGG6P Parry Gas Griddle...

Страница 2: ......

Страница 3: ...ns 7 Maintenance Instructions 7 8 Replacing Faulty Components 9 10 Fault Finding 10 Conversion Instructions 11 Technical Instructions 12 Service Information 13 Exploded View 14 Parts List 15 Replaceme...

Страница 4: ...hermostat dials ensure complete control during cooking It leads the industry in Design and aesthetic appeal Performance Power Functionality After sales support PGG6 PGG6P Unpacked weight kg 55 55 Pack...

Страница 5: ...d the Health and Safety at Work Act All commercial gas catering equipment is recommended to be mounted below an extraction canopy Please consult a ventilation engineer or refer to Guidelines DW172 to...

Страница 6: ...ppliance should be installed with sufficient ventilation to prevent the occurrence of unacceptable concentrations of substances harmful to health in the room in which it is installed POSITIONING The a...

Страница 7: ...ce The gas hose must comply with the national requirements in force and be CE marked of a metal braided construction suitable for commercial catering equipment The hoses should be periodically examine...

Страница 8: ...process for at least 2 minutes to allow gas to disperse 5 Turn knob anti clockwise to obtain main gas The lowest setting has been set at the factory and sealed This must not be adjusted by user 6 To t...

Страница 9: ...remove carbon build up Once this has been done seasoning of the plate will be necessary Never clean the unit with water jets Maintenance Instructions Ensure the appliance is isolated from the power s...

Страница 10: ...obs and remove 2 screws from the underside of the fascia panel Remove the nut from the underside of the griddle plate The plate can then slide forwards and be lifted off after withdrawing thermostat p...

Страница 11: ...ilot burner Remove the faulty thermocouple Push the new thermocouple gently into the gas cock and tighten the nut Do not over tighten Fit the probe into the pilot burner and tighten the nut To replace...

Страница 12: ...ult Finding Fault Check Solution Unit will not light Check gas supply is turned on Turn on gas supply Check to see if a spark is visible through inspection hole when piezo is pressed If no spark conta...

Страница 13: ...one by a qualified Gas Safe Engineer and as this setting has been factory sealed Any alterations must be resealed LPG to Natural Remove fascia panel 2 screws underneath Remove fascia panel and disconn...

Страница 14: ...RAL G20 20mb 8 W G 2 400 KW 8190Btu h PROPANE G31 37mb 14 8 W G 2 726 KW 9300 Btu h Gas Rate M HR FT HR LB HR KG HR NATURAL G20 0 254 8 970 PROPANE G31 0 112 3 938 0 433 0 196 AIR FLOW RATE FOR COMBUS...

Страница 15: ...person Enhanced 2 Years Warranty Parry Catering Midlands Ltd offer an enhanced warranty of two years including parts and labour on all of the Parry manufactured products To take advantage of this you...

Страница 16: ...Parry British Built for Purpose IN270 2 14 Exploded View...

Страница 17: ...Drawer No Code X1 12 Flame safety Gas Valve 8mm CW low rate adjuster GASTAP8 1 X2 12a 8mm Olive OLVCOMPR8 X2 12b Nut 8mm Tube NUTTUB8MM X2 13 Saddle Bracket for Gas Valve BRACKET01 X2 14 HT Cable CAB...

Страница 18: ...ts Part Number Description PGG7 NATURAL CONVERSION KIT CONSISTS OF INJECT130 NATURAL INJECTOR PGG6 14 X2 SET OF LABELS X1 IN103 4 INSTRUCTION PACK X1 LPG CONVERSION KIT CONSISTS OF INJECT082 LPG INJEC...

Страница 19: ...at Parry s discretion whether to repair or replace the equipment The warranty only applies if the equipment has been used in a professional manner following the manufacturer s instructions and mainte...

Страница 20: ...astic trays Foil used on racks blockages and lime scale issues Failure to grant access for pre arranged service call Equipment that has been set up or used incorrectly e g dishwasher detergents levell...

Страница 21: ...Parry British Built for Purpose IN270 2 19 Disposal Recycling The packaging should be disposed of in accordance with the regulations in force...

Отзывы: