background image

  

 

Parry

-British Built for Purpose 

IN270-2

 

  Replacing Faulty Components 

 

 

 

 

MAINTENANCE AND SERVICE MUST ONLY BE UNDERTAKEN BY REGISTERED FITTERS. 

 
Disconnect from gas and remove fascia panel. 
 

To replace the ignitor lead – 

Pull the lead from the generator body, ignitor and electrode and push the new lead onto the 
terminals. Ensure that the lead is routed to avoid direct contact with the burner flame and 
any hot surfaces. 
 

To replace the spark generator body – 

The generator is held on the front panel by a back nut. It is recommended that a new ignitor 
lead is fitted when replacing the generator. 
 

To replace thermocouple – 

Undo the nut holding the thermocouple at the rear of the gas cock and undo the nut at pilot 
burner. Remove the faulty thermocouple. 
 
Push the new thermocouple gently into the gas cock and tighten the nut. Do not over-
tighten. Fit the probe into the pilot burner and tighten the nut.  
 

To replace the combined flame safety/gas cock unit – 

Undo the union at gas cock 
 
Undo and remove the nut holding the thermocouple to the rear of the gas cock and remove 
gas cock knob. 
 
Undo and remove pilot supply from the tap. 
 
Remove thermostat phial from plate if not already done so. 
 
The gas cock is held on the float rail by a saddle bracket with two screws. Remove the 
screws and the faulty tap. 
 
Refit the new unit ensuring that the loose spigot is pushed firmly into its housing and seat 
the rubber washer in the recess provided. Refit the saddle bracket and tighten the two 
screws. 
 
Reconnect gas feed to injector and gas cock and tighten 
 
Refit pilot supply 
 
Refit thermocouple and tighten do not over tighten 
 

Содержание PGG6

Страница 1: ...Instruction Manual PGG6 PGG6P Parry Gas Griddle...

Страница 2: ......

Страница 3: ...ns 7 Maintenance Instructions 7 8 Replacing Faulty Components 9 10 Fault Finding 10 Conversion Instructions 11 Technical Instructions 12 Service Information 13 Exploded View 14 Parts List 15 Replaceme...

Страница 4: ...hermostat dials ensure complete control during cooking It leads the industry in Design and aesthetic appeal Performance Power Functionality After sales support PGG6 PGG6P Unpacked weight kg 55 55 Pack...

Страница 5: ...d the Health and Safety at Work Act All commercial gas catering equipment is recommended to be mounted below an extraction canopy Please consult a ventilation engineer or refer to Guidelines DW172 to...

Страница 6: ...ppliance should be installed with sufficient ventilation to prevent the occurrence of unacceptable concentrations of substances harmful to health in the room in which it is installed POSITIONING The a...

Страница 7: ...ce The gas hose must comply with the national requirements in force and be CE marked of a metal braided construction suitable for commercial catering equipment The hoses should be periodically examine...

Страница 8: ...process for at least 2 minutes to allow gas to disperse 5 Turn knob anti clockwise to obtain main gas The lowest setting has been set at the factory and sealed This must not be adjusted by user 6 To t...

Страница 9: ...remove carbon build up Once this has been done seasoning of the plate will be necessary Never clean the unit with water jets Maintenance Instructions Ensure the appliance is isolated from the power s...

Страница 10: ...obs and remove 2 screws from the underside of the fascia panel Remove the nut from the underside of the griddle plate The plate can then slide forwards and be lifted off after withdrawing thermostat p...

Страница 11: ...ilot burner Remove the faulty thermocouple Push the new thermocouple gently into the gas cock and tighten the nut Do not over tighten Fit the probe into the pilot burner and tighten the nut To replace...

Страница 12: ...ult Finding Fault Check Solution Unit will not light Check gas supply is turned on Turn on gas supply Check to see if a spark is visible through inspection hole when piezo is pressed If no spark conta...

Страница 13: ...one by a qualified Gas Safe Engineer and as this setting has been factory sealed Any alterations must be resealed LPG to Natural Remove fascia panel 2 screws underneath Remove fascia panel and disconn...

Страница 14: ...RAL G20 20mb 8 W G 2 400 KW 8190Btu h PROPANE G31 37mb 14 8 W G 2 726 KW 9300 Btu h Gas Rate M HR FT HR LB HR KG HR NATURAL G20 0 254 8 970 PROPANE G31 0 112 3 938 0 433 0 196 AIR FLOW RATE FOR COMBUS...

Страница 15: ...person Enhanced 2 Years Warranty Parry Catering Midlands Ltd offer an enhanced warranty of two years including parts and labour on all of the Parry manufactured products To take advantage of this you...

Страница 16: ...Parry British Built for Purpose IN270 2 14 Exploded View...

Страница 17: ...Drawer No Code X1 12 Flame safety Gas Valve 8mm CW low rate adjuster GASTAP8 1 X2 12a 8mm Olive OLVCOMPR8 X2 12b Nut 8mm Tube NUTTUB8MM X2 13 Saddle Bracket for Gas Valve BRACKET01 X2 14 HT Cable CAB...

Страница 18: ...ts Part Number Description PGG7 NATURAL CONVERSION KIT CONSISTS OF INJECT130 NATURAL INJECTOR PGG6 14 X2 SET OF LABELS X1 IN103 4 INSTRUCTION PACK X1 LPG CONVERSION KIT CONSISTS OF INJECT082 LPG INJEC...

Страница 19: ...at Parry s discretion whether to repair or replace the equipment The warranty only applies if the equipment has been used in a professional manner following the manufacturer s instructions and mainte...

Страница 20: ...astic trays Foil used on racks blockages and lime scale issues Failure to grant access for pre arranged service call Equipment that has been set up or used incorrectly e g dishwasher detergents levell...

Страница 21: ...Parry British Built for Purpose IN270 2 19 Disposal Recycling The packaging should be disposed of in accordance with the regulations in force...

Отзывы: