INSTRUCTION REF: IN145 ISSUE No. 2 DATE 25.02.09 Page 1 of 13
www.parry.co.uk
INSTALLATION INSTRUCTIONS
SAFETY INSTRUCTIONS
USER INSTRUCTIONS
PARAGON GAS FRYER
MODEL : PDGF/PDGFP
Страница 1: ...INSTRUCTION REF IN145 ISSUE No 2 DATE 25 02 09 Page 1 of 13 www parry co uk INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS PARAGON GAS FRYER MODEL PDGF PDGFP...
Страница 2: ...ensure the correct ventilation requirements are met Attention should also be drawn to the need for regular servicing In normal use parts of the catering equipment may become hot suitable precautions m...
Страница 3: ...WARNING DO NOT LIGHT BURNERS WHEN THE PAN IS EMPTY 1 Open the compartment door ensure the drain valves are closed and check the level of cooking oil between maximum and minimum markings The oil requir...
Страница 4: ...ill prolong the life of the oil CLEANING INSTRUCTIONS The appliance should be cleaned with hot water and a mild detergent DO NOT USE ABRASIVES 1 Isolate the appliance from the gas supply 2 Allow oil t...
Страница 5: ...again Leave it for 30 seconds before repeating the 5 10 seconds cycle Continue to repeat until the fat has melted so that any remaining unmelted pieces are free floating then turn the thermostat to th...
Страница 6: ...avoid splashing of the oil or fat and prevent the fish sinking and sticking to the base of the pan Cooking Chart the following chart is for guidance only Maximum basket load not to exceed 3 lbs FOOD...
Страница 7: ...the temperature of the oil or fat as recommended by the supplier Do not overload the fryer Remove the crumbs or pieces floating on the surface of the oil When using frozen foods follow the food manuf...
Страница 8: ...ions secure Yes No Is there gas at the point when holding control knob in the pilot position Tighten connection Yes Very little No Check overtemperature stat for open circuit Check supply Check supply...
Страница 9: ...temperature stat operates Is the temperature over 220 C Yes No Does the control stat operate on temp rise when set point is low 100 C Replace control stat Yes No Check calibration of control stat See...
Страница 10: ...7kw PROPANE GAS G31 37mbar 24 80kw BUTANE GAS G30 28mbar 24 80kw G25 25mbar 25 00kw G25 20mbar 24 00kw TOTAL GAS RATE NATURAL GAS G20 20mbar 2 45 M hr PROPANE GAS G31 37mbar 0 94 M hr BUTANE GAS G30...
Страница 11: ...BUTANE GAS 28mb 11 2 W G Adjust governor if necessary Only leave burner on for a minimum amount of time to ensure fryer does not get too hot 4 Turn the thermostat to off and ensure both burners exting...
Страница 12: ...fryer 2 Remove screws from mounting bracket 3 Remove the thermostat gland nut 4 Release thermostat phial from clip inside tank 5 Pull stat through tank there will be some resistance felt due to the pa...
Страница 13: ...t in reverse order SPARES LIST PDGF FRYER No off PARTS DESCRIPTION PART No 2 MULTI FUNCTION GAS VALVE VALVE7000 2 PILOT ASSEMBLY C W ELECTRODE PILOT7000 2 SAFETY LIMIT THERMOSTAT TMSTL7000 2 THERMOCOU...