FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE
TROUBLESHOOTING YOUR FAN.
WARNING
!
13. Troubleshooting
TROUBLE
PROBABLE CAUSE
SUGGESTED REMEDY
1. Fan will not start.
1. Fuse or circuit breaker blown.
1. Check main and branch circuit fuses or circuit breakers.
2. Loose power line connections to the fan.
2. Check line power connections to fan.
3. Fan/Light wall control is OFF.
3. Turn ON fan/light wall control.
4. Wall control is not programmed.
4. Program the wall control and receiver per the Owner’s
Manual instructions.
5. Reverse switch in neutral position.
5. Make sure reverse switch position is all the way to one
side.
2. Fan sounds
1. Blades not attached to fan.
1. Attach blades to fan before operating.
noisy.
2. Screws securing fan motor to motor
2. Check to make sure the screws which attach the blades
hub are loose.
to the motor are tight.
3. Screws holding blades to motor are loose.
3. Tighten screws securely.
4. The shade assembly is loose.
4. Tighten the shade assembly securely.
5. Hanger bracket and/or ceiling outlet box is
5. Tighten the hanger bracket screws to the outlet box,
not securely fastened.
and/or secure outlet box.
3. Fan wobbles
1. Screws securing fan blades to motor are
1. Check to be sure screws which attach the fan blade to
excessively.
loose.
the motor are tight.
2. Set screw in motor coupler is loose.
2. Raise coupler cover and tighten the set screw securely.
3. Fan blades out of balance.
3. Interchanging an adjacent (side by-side) blade pair can
redistribute the weight and result in smoother operation.
Or use supplied balancing kit to balance blades.
4. Hanger bracket and/or ceiling outlet box is
4. Tighten the hanger bracket screws to the outlet box,
not securely fastened.
and/or secure outlet box.
5. Set screw in hanger ball/downrod assembly 5. Tighten the set screw in the hanger ball/downrod
is loose.
assembly.
6. Screws securing fan motor to the motor hub 6. Check to be sure the screws which attach the
are loose.
motor to the motor hub are tight.
4. Light fixture will
1. Loose electrical connectors.
1. Shut off the branch circuit electricity at the fuse box or
not illuminate.
breaker panel and check the electrical connectors for
proper installation.
Make sure main power is turned OFF.
WARNING
!
Make sure main power is turned OFF.
WARNING
!
TROUBLE
PROBABLE CAUSE
SUGGESTED REMEDY