Parrot Uncle BBCF444 Скачать руководство пользователя страница 2

Table of Contents

2

Section 

Page

Safety Instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

1. Unpacking Instructions  . . . . . . . . . . . . . . . . . . . . . . . . . .3-4

2. Electrical Requirements  . . . . . . . . . . . . . . . . . . . . . . . . . . 4

3. Ceiling Fan Assembly  . . . . . . . . . . . . . . . . . . . . . . . . . . .5-9

4. How to Hang Your Ceiling Fan  . . . . . . . . . . . . . . . . . .10-11

5. How to Wire Your Ceiling Fan   . . . . . . . . . . . . . . . . . .12-16

6. Final Assembly  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17-19

7. Wall Control Procedures . . . . . . . . . . . . . . . . . . . . . . . . . 20

8. Wall Control Installation . . . . . . . . . . . . . . . . . . . . . . . .21-24

9. Programming the Receiver Operating Frequency . . . . . . 25

10. Wall Control Operation  . . . . . . . . . . . . . . . . . . . . . . . . . 25

S

ection 

Page

11. Using Your Ceiling Fan . . . . . . . . . . . . . . . . . . . . . . . . .  26

12. Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

13. Troubleshooting

 

27

14.

 Instruction to the User

 

. . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

28

15.

 

28

 Energy Efficient Use of Ceiling Fan  . . . . . . . . . . . . . . .

Safety Instructions

TO  REDUCE  THE  RISK  OF  FIRE,  ELECTRICAL 

SHOCK,  OR  INJURY  TO  PERSONS,  OBSERVE  THE 

FOLLOWING:
a.  Use  this  unit  only  in  a  manner  intended  by  the 

manufacturer.    If  you  have  questions,  contact  the 

manufacturer.

b.  Before  servicing  or  cleaning  unit,  switch  power 

off  at  service  panel  and  lock  service  panel 

disconnecting  means  to  prevent  power  from 

being  switched  on  accidentally.  When  the  service 

disconnecting  means  cannot  be  locked,  securely 

fasten  a  warning  device,  such  as  a  tag,  to  the 

service panel.

 

WARNING

!

Additional Safety Instructions for Installation

1.  To avoid possible shock, be sure electricity is turned 

off  at  the  fuse  box  before  wiring,  and  do  not  operate 

fan without blades.

2.  All  wiring  must  be  in  accordance  with  the  National 

Electrical  Code  “ANSI/NFPA  70-2017”  and  Local 

Electrical  Codes.  Use  the  National  Electrical  Code 

if  Local  Codes  do  not  exist.  The  ceiling  fan  must  be 

grounded  as  a  precaution  against  possible  electrical 

shock.  Electrical  installation  should  be  made  or 

approved by a licensed electrician.

3.  The  outlet  box  and  joist  must  be  securely  mounted 

and capable of reliably supporting at least 50 pounds. 

Use  only  U.L.  outlet  boxes  listed  as  “Acceptable  for 

Fan  Support  of  22.7  kg.  (50  lbs.)  or  less”,  and  use 

the  mounting  screws  provided  with  the  outlet  box. 

Most outlet boxes commonly used for support of light 

fixtures  are  not  acceptable  for  fan  support  and  may 

need  to  be  replaced.  Consult  a  qualified  electrician 

if in doubt.

4.  The  downrod  furnished  with  the  fan  provides  the 

minimum  recommended  floor  to  fan  blade  clearance 

for an 8 foot ceiling.

5.  Follow  the  recommended  instructions  for  the  proper 

method of wiring your ceiling fan. If you do not know 

enough about electrical wiring, have your fan installed 

by a licensed electrician.

NOTE: 

This fan is suitable for use with solid-state speed 

controls.

NOTE: 

All set screws must be checked and re-tightened 

where necessary before installation.

1.  Read  your  owner’s  manual  carefully  and  keep  it  for 

future reference.

2.  Be  careful  of  the  fan  and  blades  when  cleaning, 

painting, or working near the fan. Always turn off the 

power to the ceiling fan before servicing.

3.  Do not put anything into the fan blades while they are 

turning.

4.  Do not operate reversing switch until fan blades have 

come to a complete stop.

READ AND SAVE THESE INSTRUCTIONS

To reduce the risk of electrical shock, this fan must be 

installed with an isolating wall control/switch.

To  reduce  the  risk  of  fire  or  electrical  shock,  this  fan 

should only be used with fan speed control, Model No. 

UC7067RA, manufactured by Rhine Electric Co., Ltd.

To avoid fire, shock or injury, do not use  any  other 

brand  of  control  not  specifically approved for this fan.  
This  product  is  designed  to  use  only  those  parts

supplied  with  this  product  and/or  any  accessories

designated  specifically  for  use  this  product.

Substitution of parts or accessories not designated 

for  use  with  this  product could result  in  personal 

injury or property damage.           
To  reduce  the  risk  of  personal  injury,  do  not  bend 

the  blades  during  installation,  balancing  the  blades 

or  cleaning  the  fan.  Do  not  insert  foreign  objects  in 

between rotating fan blades.

 

WARNING

!

To reduce the risk of injury, install the fan so that the 

blades are at least 7 ft. (2.1m) above the floor.

 

CAUTION

!

Содержание BBCF444

Страница 1: ...CEILING FAN 54 Ceiling Fan Owner s Manual BBCF444...

Страница 2: ...with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The down...

Страница 3: ...ocal retailer or catalog outlet for replacement before proceeding L A G B C K E D F H I OFF ON OFF ON J PACKAGE CONTENTS 6 5 9 7 8 4 3 2 1 10 HARDWARE CONTENTS Part Description Quantity A Fan Motor As...

Страница 4: ...Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING Your New Ceiling Fan wi...

Страница 5: ...of the remaining Three Blades per the above instructions A spare 8 32 x 11 mm Washer Head Blade Screw is supplied in the parts bag if needed 5 To reduce the risk of personal injury do not bend the bla...

Страница 6: ...the Three previously removed 6 32 x 3 8 Pan Head Screws with Lockwashers into the Light Fixture Adapters Slots and securely tighten all screws Figure 3 A spare 6 32 x 3 8 Pan Head Screw with Lockwashe...

Страница 7: ...lue and White Motor Wires through the 6 Downrod Figure 5 MOTOR COUPLER DOWNROD LOOSEN SET SCREWS 2 Figure 6 3 6 Loosen the Two Phillips Head Set Screws in the Motor Coupler for installation of the 6 D...

Страница 8: ...ARNING 6 DOWNROD GROMMET COUPLER COVER MOTOR HOUSING Figure 9 3 9 Make sure the Grommet is properly installed in the Coupler Cover then slide the Coupler Cover on the 6 Downrod until it rests on the M...

Страница 9: ...an wobble 6 DOWNROD CEILING COVER Figure 10 3 10 Place the Ceiling Cover over the 6 Downrod Figure 10 Be sure that the Ceiling Cover and the Coupler Cover are both oriented correctly Figure 10 BLACK W...

Страница 10: ...ARNING MAIN FUSE BOX On I On I On I On I On I On I On I On I Figure 14 4 1 Disconnect Electrical Power to the Branch Circuit at the Circuit Breaker or Fuse Box before attempting to install the Ceiling...

Страница 11: ...t WARNING Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard WARNING OUTLET BOX HANGER BRACKET HANGER BALL DOWNROD ASSEMBLY NOTE CEILING COVER SUPPL...

Страница 12: ...e Box before attempting to Wire the Ceiling Fan 5 How to Wire Your Ceiling Fan To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring NOTE If you are n...

Страница 13: ...bag and the receiver hardware bag Make sure that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the supply circuit ground wire Connect th...

Страница 14: ...T O R N AC IN N AC IN L F O R L I G H T FAN AND RECEIVER WHITE WIRES 18 ga WIRE CONNECTOR Figure 21 5 5 Securely connect the Receiver Black Wire AC IN L to the Supply Black Wire HOT using the 12 ga Wi...

Страница 15: ...e Hanger Bracket Figure 23 NOTE Failure to properly connect the Receiver Wires will damage the device and render it non operable T O M O T O R N AC IN N AC IN L F O R L I G H T T O M O T O R L SUPPLY...

Страница 16: ...s on one side of the Outlet Box and position the Black and Blue Wires on the other side of the Outlet Box Figure 24 GND STANDARD ON OFF WALL SWITCH OR OPTIONAL WALL CONTROL BLACK BLACK WHITE BLACK or...

Страница 17: ...uds and turn until Studs protrude through the Ceiling Cover Holes Figure 27 Secure the Ceiling Cover in place by sliding a Lockwasher over each of the Threaded Studs and installing the two Knurled Kno...

Страница 18: ...ure assembly and the light fixture adapter Install and tighten the Three 6 32 x 1 4 Pan Head Screws with Lockwashers supplied to complete the installation of the LED Light Fixture Assembly Figure 29 A...

Страница 19: ...sing SHADE ASSEMBLY SHADE ASSEMBLY FLAT SIDES 4 INNER LOWER HOUSING FLAT SIDES 4 SHADE ASSEMBLY KEY HOLE SLOTS 4 INNER LOWER HOUSING PROTRUDING STUDS 4 Figure 31 You have now completed the assembly of...

Страница 20: ...vers in the Wall Control to your choice of ON up or down positions Use a ball point pen or small screwdriver and slide the Levers firmly up or down The Sixth Switch marked ON and I is for Dimming Cont...

Страница 21: ...To avoid possible electrical shock be sure electricity is turned off at the main fuse or circuit breaker box before wiring All wiring must be in accordance with National and Local codes and the ceili...

Страница 22: ...ll Control Installation Continued Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse or circuit breaker box before wiring A...

Страница 23: ...ire connectors supplied Make sure that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire Before installing the First Wall Co...

Страница 24: ...Control onto the Wall Box using the supplied Screws Leave the Wall Control in OFF mode until Fan installation is completed NOTE Retrofit 3 way installations are likely to include two traveler wires b...

Страница 25: ...ch Circuit at the Circuit Breaker or Fuse Box Flip the Wall Control s ON OFF Switch to ON position Within one minute of flipping the Switch to ON push and hold the FAN POWER OFF Button for 3 to 5 seco...

Страница 26: ...R ASSEMBLY Figure 38 11 1 Restore Electrical Power to the Outlet Box by turning the Electricity on at the Main Fuse Box During Summer Months run the Fan Counter Clockwise as you look up at it to direc...

Страница 27: ...he hanger bracket screws to the outlet box not securely fastened and or secure outlet box 3 Fan wobbles 1 Screws securing fan blades to motor are 1 Check to be sure screws which attach the fan blade t...

Страница 28: ...limits for a class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equ...

Страница 29: ......

Отзывы: