manualshive.com logo in svg
background image

13

14

IMPORTANT NOTE ABOUT 74% CUTOFF: This 

option will activate the soft cutoff at 74% of startup 

voltage or 9.2V, whichever is higher. For example, 

if your pack measures 16.8 volts at startup, then 

the soft cut will occur at 12.4 volts. The 

74% cutoff 

option will check the startup voltage every time you 

plug the battery into the controller, so beware of 

using partially charged packs, as the system cannot 

protect your Li-Po batteries if you are using the 74% 

cutoff and connect a partially charged pack. You will 

know your battery pack has reached soft auto cutoff 

when you hear the motor “pulse” repeatedly. We 

recommend you land your model as soon as you 

hear the motor pulse (indicating the pack voltage has 

dropped to the cutoff voltage level) to prevent over-

discharge of the Li-Po battery pack, and to prevent 

sudden power loss.

Programming Menu 2 – Brake Type

The default setting is Brake Off. This option gives you the 

choice to have the ESC stop the propeller during flight 

(Brake On) or allow it to windmill (Brake Off). Use the 

Brake On options for folding propellers.

1.  Move the stick to center (between 1.4 and 1.6ms) 

for 5 seconds, and the controller will beep 2 times, 

indicating you are now in Menu 2. 

2.  Move the throttle stick to full throttle (>1.7ms) 

position to  make changes to the Brake Type 

programming. 

   a.  To select No Brake/Brake Off – You will hear 

1 short beep. Move the throttle stick to center 

(between 1.4 and 1.6ms). The controller will beep 

2 times, indicating you have set the program 

selection or leave in full throttle for 5 seconds to 

advance to the next selection. 

   b.  To select Soft Brake – You will hear 2 short beeps. 

Move the throttle stick to center (between 1.4 

and 1.6ms).  The controller will beep 2 times, 

indicating you have set the program selection or 

leave in full throttle for 5 seconds to advance to 

the next selection. 

   c.  To select Medium Brake – You will hear 3 short 

beeps. Move the throttle stick to center (between 

1.4 and 1.6ms). The controller will beep 2 times, 

indicating you have set the program selection or 

leave in full throttle for 5 seconds to advance to 

the next selection. 

   d.  To select Hard Brake – You will hear 4 short 

beeps. Move the throttle stick to center (between 

1.4 and 1.6ms). The controller will beep 2 times, 

indicating you have set the program selection or 

leave in full throttle for 5 seconds to advance to 

the first selection again.

Programming Menu 3 – Timing

The default setting is 15 degrees. As a general rule, 

lower pole count motors use lower timing and higher 

pole count motors use higher timing. Please refer to your 

motor instructions and specifications for an indication of 

the number of poles.

LowTimingAdvance

     Timing Degrees – 5 & 10 

Motor Poles – 2 to 4  

Expected Performance – Good balance of power and 

efficiency 

Motor Poles – 6 or more 

Expected Performance – Best efficiency and run time 

(lowest power)

StandardTimingAdvance

     Timing Degrees – 15 & 20 

 Motor Poles – 6 to 12 

Expected Performance – Good balance of power and 

efficiency 

Motor Poles – 14 or more 

Expected Performance – Best efficiency and run time 

(lowest power)

HighTimingAdvance

     Timing Degrees – 25 

Motor Poles – 12  

Expected Performance – Highest power, less 

efficiency 

Motor Poles – 14 or more 

Expected Performance – Good balance of power and 

efficiency

1.  Move the stick to center (between 1.4 and 1.6ms) 

for 5 seconds, and the controller will beep 3 times, 

indicating you are now in Menu 3. 

2.  Move the throttle stick to full throttle (>1.7ms) 

position to make changes to the Timing 

programming.

   a.  To select 5 Degrees – You will hear 1 short beep. 

Move the throttle stick to center (between 1.4 and 

1.6ms). The controller will beep 2 times, indicating 

you have set the program selection or leave in 

full throttle for 5 seconds to advance to the next 

selection. 

   b.  To select 10 Degrees – You will hear 2 short 

beeps. Move the throttle stick to center (between 

1.4 and 1.6ms). The controller will beep 2 times, 

indicating you have set the program selection or 

leave in full throttle for 5 seconds to advance to 

the next selection. 

   c.  To select 15 Degrees – You will hear 3 short 

beeps. Move the throttle stick to center (between 

1.4 and 1.6ms). The controller will beep 2 times, 

indicating you have set the program selection or 

leave in full throttle for 5 seconds to advance to 

the next selection. 

   d.  To select 20 Degrees – You will hear 4 short 

beeps. Move the throttle stick to center (between 

1.4 and 1.6ms). The controller will beep 2 times, 

indicating you have set the program selection or 

leave in full throttle for 5 seconds to advance to 

the next selection. 

   e.  To select 25 Degrees – You will hear 5 short 

beeps. Move the throttle stick to center (between 

1.4 and 1.6ms). The controller will beep 2 times, 

indicating you have set the program selection or 

leave in full throttle for 5 seconds to advance to 

the first selection again.

Programming Menu 4 – Throttle Input Range 

(PWM)

The default setting is 1.2ms to 1.8ms and should work 

with most radio systems. This option allows for proper 

throttle input with many different radio systems. However, 

some radios have a wider output range, and may give 

a more linear response with the 1.1ms to 1.9ms range. 

If you feel there is too much “dead” area in the stick 

movement near full throttle, try adjusting the end points 

in your radio, or change to the wider input range. Be 

aware that if these settings are not correct, it may be 

impossible to arm the controller.

1.  Move the stick to center (between 1.4 and 1.6ms) 

for 5 seconds, and the controller will beep 4 times, 

indicating you are now in Menu 4. 

2.  Move the throttle stick to full throttle (>1.7ms) 

position to make changes to the Throttle Input 

Range programming. 

   a.  To select 1.2ms to 1.8ms – You will hear 1 short 

beep. Move the throttle stick to center (between 

1.4 and 1.6ms). The controller will beep 2 times, 

indicating you have set the program selection or 

leave in full throttle for 5 seconds to advance to 

the next selection. 

   b.  To select 1.1ms to 1.9ms – You will hear 2 short 

beeps. Move the throttle stick to center (between 

1.4 and 1.6ms). The controller will beep 2 times, 

indicating you have set the program selection or 

leave in full throttle for 5 seconds to advance to 

the first selection again.

Programming Menu 5 – Start-Up Rate 

The default setting is 0.25 seconds. The start-up rate 

is the time it takes to reach maximum motor speed. 

Changing the setting to 1 second can be useful with 

power-fragile gear boxes.

1.  Move the stick to center (between 1.4 and 1.6ms) 

for 5 seconds, and the controller will beep 5 times, 

indicating you are now in Menu 3. 

2.  Move the throttle stick to full throttle (>1.7ms) 

position to make changes to the Start-up Rate 

programming. 

   a.  To select .25 second – You will hear 1 short beep. 

Move the throttle stick to center (between 1.4 and 

1.6ms). The controller will beep 2 times, indicating 

you have set the program selection or leave in 

full throttle for 5 seconds to advance to the next 

selection. 

   b.  To select 1 second – You will hear 2 short beeps. 

Move the throttle stick to center (between 1.4 and 

1.6ms). The controller will beep 2 times, indicating 

you have set the program selection or leave in 

full throttle for 5 seconds to advance to the first 

selection again.

Programming Menu 6 – PWM Switching 

Frequency

The default setting is 8KHz, which should be acceptable 

for most motors. If you have a low or very low 

inductance motor and know you need to use a higher 

PWM Frequency (refer to the manual included with the 

motor), then you can change the setting. Otherwise, we 

recommend leaving the default setting.

1.  Move the stick to center (between 1.4 and 1.6ms) 

for 5 seconds, and  the controller will beep 6 times, 

indicating you are now in Menu 6. 

2.  Move the throttle stick to full throttle (>1.7ms) 

position to make changes to the PWM Switching 

Frequency programming. 

   a.  To select 8KHz PWM Frequency – You will hear 

1 short beep. Move the throttle stick to center 

(between 1.4 and 1.6ms). The controller will beep 

2 times, indicating you have set the program 

selection or leave in full throttle for 5 seconds to 

advance to the next selection. 

   b.  To select 16KHz PWM Frequency – You will hear 

2 short beeps. Move the throttle stick to center 

(between 1.4 and 1.6ms). The controller will beep 

2 times, indicating you have set the program 

Содержание T-28D Trojan BNF

Страница 1: ...ed exclusively by Horizon Hobby Inc 4105 Fieldstone Road Champaign IL 61822 USA 2009 Horizon Hobby Inc Horizon Hobby UK Units 1 4 Ployters Rd Staple Tye Harlow Essex CM18 7NS United Kingdom Horizon Ho...

Страница 2: ...d Specifications Input power 12V DC 3A Charges 2 to 3 cell Li Po packs with minimum capacity of 300mAh Variable charge rates from 300mAh to 2 amps 3S 11 1V 1800mAh Li Po Battery Pack The ParkZone 3S L...

Страница 3: ...smitter and have full control and function Remove and store bind plug in a safe place If you encounter any problems repeat the binding process again see the troubleshooting guide or call the Horizon S...

Страница 4: ...ew to thread into the fuselage Once you are certain the wing is centered tighten the screw to secure the wing 7 The wing is correctly installed when no gap exists between the wing and fillet 8 Gently...

Страница 5: ...6 Make any trim adjustments as necessary prior to flight see Step 10 Note To make trim adjustments to the horizontal stabilizer a Turn on radio transmitter b Plug in fully charged battery into fuse c...

Страница 6: ...dual rates switch is set at where you plan on flying We recommend LOW rates for your initial flying The T 28D Trojan BNF is VERY maneuverable on high rates and requires a lot of experience to handle p...

Страница 7: ...roller is armed 3 When you move the throttle stick upward the motor will run Continue to move the throttle stick upward to the full throttle high position and the motor will run faster When the thrott...

Страница 8: ...ction c To select 15 Degrees You will hear 3 short beeps Move the throttle stick to center between 1 4 and 1 6ms The controller will beep 2 times indicating you have set the program selection or leave...

Страница 9: ...event a crash Remember you must wait more than 5 seconds after stopping the motor ESC in order for the 5 second start up to occur again 1 Move the stick to center between 1 4 and 1 6ms for 5 seconds a...

Страница 10: ...repair left unpaid or unclaimed after 90 days will be considered abandoned and will be disposed of accordingly Please note non warranty repair is only available on electronics and model engines United...

Страница 11: ...ion and Repairs Compliance Information for the European Union Instructions for Disposal of WEEE by Users in the European Union This product must not be disposed of with other waste Instead it is the u...

Страница 12: ...21 22...

Отзывы: