54 GB/IE
Turn the rotary knob 3 to
/ .
Press
SELECT
4 repeatedly until
18 is
shown in the display 6 .
Connect
–
the red test probe 9 to the anode of the
diode to be tested and
–
the black test probe 9 to the cathode of the
diode .
The approximate forward voltage drop of the
diode is shown in the display 6 .
NOTE:
If the connections are reversed:
OL
is
shown in the display 6 .
Measuring capacitance
Connect
–
the black test probe 9 to
COM
8 and
–
the red test probe 9 to
7 .
Turn the rotary knob 3 to .
If the display 6 shows a reading other than
0
:
–
Press
REL
11 to set the value to
0
.
–
REL
16 is shown in the display .
Discharge the capacitor to be tested .
Connect the test probes 9 to the 2 leads of
the capacitor .
The reading is shown in the display 6 .
Содержание PZM 2 A1
Страница 2: ...DE AT CH Seite 5 GB IE Page 33 FR BE Page 61 NL BE Pagina 90 PL Strona 118 CZ Strana 145 SK Strana 172...
Страница 3: ...HG05550A PZM 2 A1 REL A 2 1 3 4 5 6 7 8 9 11 12 10...
Страница 4: ...HG05550A PZM 2 A1 REL B C 13 14 15 16 17 18 19 20 21 22 23 24...
Страница 199: ...OWIM GmbH Co KG Stiftsbergstra e 1 74167 Neckarsulm GERMANY Model No HG05550A Version 11 2019 IAN 308576_1904...