
22
GB
same or a similarly qualified
person in order to prevent haz-
ards.
• Do not pull the plug from the
socket by the cable. Protect the
cable from heat, oil and sharp
edges.
• Do not carry or fix the equip
-
ment by the cable.
• Use only extension cables that
are protected from spray water
and designed for outdoor use.
Always fully unroll a cable drum
before use. Check the cable for
damage.
• Disconnect the mains plug from
the socket before all work on
the equipment, in case of leaks
in the water system, during
work breaks, and when not in
use.
• Extension cables must not have
a cross-section that is smaller
than those of rubber hoses with
the designation H07RN8-F.
The cord length must be at least
10 m. The wire cross section of
the extension cable must be at
least 2.5 mm
2
.
• Perform the electrical installa
-
tion in accordance with national
regulations.
Initial Operation
Positioning/Hanging
• The dimensions of the pump shaft must
be not less than 40 x 40 x 50 cm, in
order that the float switch (
6) can
move freely.
• The device can be suspended from the
handle (
1) or placed on the bottom
of the shaft.
The pump can be suspended and/or
removed using the nylon cord (
13)
provided.
To ensure it is suspended securely,
thread the nylon cord (
13) through
the handle (
1)
as depicted in Figure
.
Never suspend the pump by the hose.
Ensure that the equipment is
not hung up or held by the
mains cable. There is a risk
of electric shock from dam-
aged mains cables.
Note that, over time, dirt and sand
may collect on the bottom of the
shaft, which could damage the
pump.
We recommend standing the pump
on a brick.
If the water level is too low, the silt in
the shaft can quickly dry out and im-
pede the pump when warming up.
Mains Connection
The pump you have purchases is already
fitted with an earthed plug. The equipment
is designed for connection to an earthed
wall socket with a RCD (Residual Current
Device) at 230 V~ 50 Hz.
Connecting the Pressure
Line
The pump is installed
-
Either with a fixed pipeline
-
Or with a flexible hose line.
1.
Screw the quick-connect adapter (10)
onto the pump outlet (8).
2.
Press the red release button on the
quick-connect adapter (
10
) and slide
Содержание PTPS 1100 B2
Страница 3: ...1 6 5 13 1 7 m 1 2 2 4 6 5 3 8 12 11 4 6 13 1 1 G 1 G 1 7 9 1 10...
Страница 92: ...92 BG 8 m p RCD Residual Current Device 30 mA 6 A 35 mm 35 C...
Страница 94: ...94 BG 7 m...
Страница 95: ...95 BG...
Страница 96: ...96 BG 75 m H07RN8 F 10 m 2 5 mm2 40 x 40 x 50 cm 6 1 13 13 1 RCD Residual Current Device 230 V 50 Hz...
Страница 98: ...98 BG 6 4 6 3 4 3 3 6 3 3 6 6 6 5 4 230 V 50 Hz 6A RCD 90 mm...
Страница 99: ...99 BG 6 12 Quick Connect 11 10 2 1...
Страница 100: ...100 BG 2012 19 3 II 3...
Страница 101: ...101 BG IAN 373774_2204...
Страница 102: ...102 BG BG 0800 12220 info kaufland bg IAN 373774_2204 20 63762 33 3 II III...
Страница 103: ...103 BG 6 6 35 C www grizzlytools shop 102 10 11 12 91110114 13 8 m 79300311...
Страница 104: ...104...
Страница 122: ...BG ERRATUM IAN 373774_2204 PTPS 1100 B2 10...