11
GB IE
c) Damages to health due to
- touching the area of the grinding tool
which was not covered;
- the ejection of pieces from workpiece
or damaged grinding discs.
d) Damage to your health caused by
swinging your hands and arms when
operating the appliance for longer pe-
riods of time or if the unit is not held or
maintained properly.
Warning! During operation, this
electric tool generates an electro-
magnetic field which, under certain
circumstances, may impair the func-
tionality of active or passive medical
implants. To reduce the risk of seri
-
ous or lethal injuries, we recommend
that persons with medical implants
consult their doctor and the manufac-
turer of their medical implant before
operating the machine.
Assembly
Caution! Risk of injury!
- Ensure that you have sufficient
space in which to work, and that
you do not endanger other peo-
ple.
- Always fasten the device on to the
work surface with screws featuring
the sufficient length and thickness
in order to maintain control of the
device.
- All covers and protective devices
must be assembled properly be-
fore commissioning.
- Disconnect the mains plug before
changing the setting on the device.
• Always wear safety glasses, safety
gloves, respiratory protection and ear
protection when grinding, brushing
and separating.
• Never keep the fingers between the
grinding disc and spark protection
or in close proximity to the protective
hoods. There is a risk of crushing.
• The rotating parts of the device cannot
be covered due to functional reasons.
Therefore, proceed cautiously and hold
the workpiece firmly in order to avoid
slipping which could cause your hands
to come into contact with the grinding
disc.
• The workpiece gets hot during grind
-
ing. Do not touch the machined area,
allow it to cool down. There is a risk
of burning. Do not use coolants or the
like.
• If you are tired or have consumed al
-
cohol or tablets, do not work with the
device. Always have a break on time.
• Switch the device off and remove the
mains plug
- to loosen a blocked insertion tool,
- if the connection line is damaged or
entangled,
- in case of unusual sounds.
Residual risks
Even if properly operating and handling
this electric tool, some residual risks will
remain. Due to its construction and build,
this electric tool may present the following
hazards:
a) Lung damage, if suitable respiratory
protection is not worn.
b) Hearing damage, if suitable ear pro-
tection is not worn.
Содержание PNTS 250 A1
Страница 3: ...1 4 5 7 8 9 10 11 12 6 3 2 13 7 6 14 11 15 16...
Страница 4: ...22 17 21 20 3 18 19 2 23 5 23 24 25 24 22 25a...
Страница 37: ...37...
Страница 38: ...38...
Страница 40: ...40 2015 07 16 rev02 op...
Страница 42: ...13 22 26 27 1 28 26 22 29...
Страница 43: ......